Learn PLCs free
Intermediate20 min readIndustrial Manufacturing

Inovance Structured Text for Motor Control

Learn Structured Text programming for Motor Control using Inovance InoProShop / AutoShop. Includes code examples, best practices, and step-by-step implementation guide for Industrial Manufacturing applications.

💻
Platform
InoProShop / AutoShop
📊
Complexity
Beginner to Intermediate
⏱️
Project Duration
1-3 weeks

Implementing Structured Text for Motor Control using Inovance InoProShop / AutoShop requires translating a control narrative into code, tests, and commissioning checks. This hands-on guide focuses on practical implementation steps, an illustrative code example, and decisions that should be recorded during design review.

The guide uses InoProShop / AutoShop terminology and Structured Text because complex calculations, data manipulation, advanced control algorithms, and when code reusability is important. Confirm language support for the selected controller and software release, then map the example's 5 sensor inputs and 5 actuator outputs to the project's reviewed I/O list.

Real Motor Control projects in Industrial Manufacturing face practical challenges including soft start implementation, overload protection, and integration with existing systems. Success requires balancing powerful for complex logic against steeper learning curve, while meeting 1-3 weeks project timelines typical for Motor Control implementations.

This guide provides step-by-step implementation guidance, an illustrative example, practical design patterns, and troubleshooting scenarios. Compile and test the adapted logic in an isolated environment, verify fail-safe behavior with the responsible controls and safety reviewers, and complete site acceptance checks before production use.

Inovance InoProShop / AutoShop for Motor Control

InoProShop / AutoShop is a programming environment associated with Inovance controller families such as AM600, AM610, H5U. This guide uses Structured Text terminology from the supplied guide dataset, but controller capabilities and language support can change by model, firmware, software edition, and license.

Verify Before You Start:

  • The selected controller supports the required Structured Text constructs

  • The project version matches the installed InoProShop / AutoShop release

  • Required communications, motion, safety, and simulation options are licensed

  • Firmware and device-description files are compatible with the project

  • The vendor manuals used for the design match the exact hardware revision


Application Planning:

For a Motor Control exercise, map the required inputs and outputs before writing logic. The example considers 5 sensor types, including Current sensors, Vibration sensors, Temperature sensors, and 5 actuator types.

Control Equipment for Motor Control:

  • Motor control centers (MCCs)

  • AC induction motors (NEMA/IEC frame)

  • Synchronous motors for high efficiency

  • DC motors for precise speed control


Controller-family references used in this guide include:

  • AM600: Confirm CPU, I/O, memory, communications, and Structured Text support in the current selection guide

  • AM610: Confirm CPU, I/O, memory, communications, and Structured Text support in the current selection guide

  • H5U: Confirm CPU, I/O, memory, communications, and Structured Text support in the current selection guide

  • AC800: Confirm CPU, I/O, memory, communications, and Structured Text support in the current selection guide


Hardware Selection Checklist:

  • Count local and remote I/O, including planned expansion

  • Measure the required task and communications update rates

  • Identify memory, data-retention, diagnostics, and cybersecurity requirements

  • Treat safety functions as a separate, standards-led design activity

  • Confirm lifecycle status, regional availability, licensing, and support


Source and Validation Note:

This page does not represent a vendor certification or a hardware acceptance test. Use current Inovance manuals, release notes, and safety documentation as the authority for product-specific behavior. Validate adapted logic in a simulator or isolated test setup before connecting it to equipment.

Investment Considerations:

For Motor Control projects, compare hardware, software licensing, training, engineering, test equipment, commissioning, spares, and ongoing support. Obtain current pricing and lifecycle information directly from the vendor or an authorized regional supplier.

Understanding Structured Text for Motor Control

Structured Text (ST) is a high-level, text-based programming language defined in IEC 61131-3. It resembles Pascal and provides powerful constructs for complex algorithms, calculations, and data manipulation.

Execution Model:

Code executes sequentially from top to bottom within each program unit. Variables maintain state between scan cycles unless explicitly reset.

Core Advantages for Motor Control:

  • Powerful for complex logic: Critical for Motor Control when handling beginner to intermediate control logic

  • Excellent code reusability: Critical for Motor Control when handling beginner to intermediate control logic

  • Compact code representation: Critical for Motor Control when handling beginner to intermediate control logic

  • Good for algorithms and calculations: Critical for Motor Control when handling beginner to intermediate control logic

  • Familiar to software developers: Critical for Motor Control when handling beginner to intermediate control logic


Why Structured Text Fits Motor Control:

Motor Control systems in Industrial Manufacturing typically involve:

  • Sensors: Current transformers for motor current monitoring, RTD or thermocouple for motor winding temperature, Vibration sensors for bearing monitoring

  • Actuators: Contactors for direct-on-line starting, Soft starters for reduced voltage starting, Variable frequency drives for speed control

  • Complexity: Beginner to Intermediate with challenges including Managing starting current within supply limits


Programming Fundamentals in Structured Text:

Variables:
- declaration: VAR / VAR_INPUT / VAR_OUTPUT / VAR_IN_OUT / VAR_GLOBAL sections
- initialization: Variables can be initialized at declaration: Counter : INT := 0;
- constants: VAR CONSTANT section for read-only values

Operators:
- arithmetic: + - * / MOD (modulo)
- comparison: = <> < > <= >=
- logical: AND OR XOR NOT

ControlStructures:
- if: IF condition THEN statements; ELSIF condition THEN statements; ELSE statements; END_IF;
- case: CASE selector OF value1: statements; value2: statements; ELSE statements; END_CASE;
- for: FOR index := start TO end BY step DO statements; END_FOR;

Best Practices for Structured Text:

  • Use meaningful variable names with consistent naming conventions

  • Initialize all variables at declaration to prevent undefined behavior

  • Use enumerated types for state machines instead of magic numbers

  • Break complex expressions into intermediate variables for readability

  • Use functions for reusable calculations and function blocks for stateful operations


Common Mistakes to Avoid:

  • Using = instead of := for assignment (= is comparison)

  • Forgetting semicolons at end of statements

  • Integer division truncation - use REAL for decimal results

  • Infinite loops from incorrect WHILE/REPEAT conditions


Typical Applications:

1. PID control: Directly applicable to Motor Control
2. Recipe management: Related control patterns
3. Statistical calculations: Related control patterns
4. Data logging: Related control patterns

Understanding these fundamentals prepares you to implement effective Structured Text solutions for Motor Control using Inovance InoProShop / AutoShop.

Implementing Motor Control with Structured Text

Motor control systems use PLCs to start, stop, and regulate electric motors in industrial applications. These systems provide protection, speed control, and coordination for motors ranging from fractional horsepower to thousands of horsepower.

This walkthrough demonstrates practical implementation using Inovance InoProShop / AutoShop and Structured Text programming.

System Requirements:

A typical Motor Control implementation includes:

Input Devices (Sensors):
1. Current transformers for motor current monitoring: Critical for monitoring system state
2. RTD or thermocouple for motor winding temperature: Critical for monitoring system state
3. Vibration sensors for bearing monitoring: Critical for monitoring system state
4. Speed encoders or tachometers: Critical for monitoring system state
5. Torque sensors for load monitoring: Critical for monitoring system state

Output Devices (Actuators):
1. Contactors for direct-on-line starting: Primary control output
2. Soft starters for reduced voltage starting: Supporting control function
3. Variable frequency drives for speed control: Supporting control function
4. Brakes (mechanical or dynamic): Supporting control function
5. Starters (star-delta, autotransformer): Supporting control function

Control Equipment:

  • Motor control centers (MCCs)

  • AC induction motors (NEMA/IEC frame)

  • Synchronous motors for high efficiency

  • DC motors for precise speed control


Control Strategies for Motor Control:

1. Primary Control: Industrial motor control using PLCs for start/stop, speed control, and protection of electric motors.
2. Safety Interlocks: Preventing Soft start implementation
3. Error Recovery: Handling Overload protection

Implementation Steps:

Step 1: Calculate motor starting current and verify supply capacity

In InoProShop / AutoShop, calculate motor starting current and verify supply capacity.

Step 2: Select starting method based on motor size and load requirements

In InoProShop / AutoShop, select starting method based on motor size and load requirements.

Step 3: Configure motor protection with correct thermal curve

In InoProShop / AutoShop, configure motor protection with correct thermal curve.

Step 4: Implement control logic for start/stop with proper interlocks

In InoProShop / AutoShop, implement control logic for start/stop with proper interlocks.

Step 5: Add speed control loop if VFD is used

In InoProShop / AutoShop, add speed control loop if vfd is used.

Step 6: Configure acceleration and deceleration ramps

In InoProShop / AutoShop, configure acceleration and deceleration ramps.


Inovance Function Design:

InoProShop strongly favours function-block reuse via the Library Manager — Inovance ships standard libraries for motion, drives, HMI, OPC UA, and industry-specific applications (lithium-battery, EV, elevator). AutoShop reuse is open-coded via P-label subroutines. OEM machine-builders increasingly default to InoProShop / AM600 to access the FB libraries.

Common Challenges and Solutions:

1. Managing starting current within supply limits

  • Solution: Structured Text addresses this through Powerful for complex logic.


2. Coordinating acceleration with driven load requirements

  • Solution: Structured Text addresses this through Excellent code reusability.


3. Protecting motors from frequent starting (thermal cycling)

  • Solution: Structured Text addresses this through Compact code representation.


4. Handling regenerative energy during deceleration

  • Solution: Structured Text addresses this through Good for algorithms and calculations.


Safety Considerations:

  • Proper machine guarding for rotating equipment

  • Emergency stop functionality with safe torque off

  • Lockout/tagout provisions for maintenance

  • Arc flash protection and PPE requirements

  • Proper grounding and bonding


Performance Metrics:

  • Task and I/O timing: Record minimum, average, and maximum values under a defined test load

  • Accuracy: Define an acceptable tolerance and compare it with calibrated reference measurements

  • Throughput: Count completed cycles over a fixed interval and record rejected or incomplete cycles

  • Fault response: Measure detection, safe-state, alarm, and recovery behavior for each test case

  • Resource use: Record memory, communications load, and diagnostic-buffer behavior

Inovance Diagnostic Tools:

InoProShop online mode with full POU monitoring and breakpoint debug,EtherCAT diagnostics page with topology and slave status,Trace tool for analogue / motion signal capture,OPC UA server diagnostics page,Modbus communication trace utility,AutoShop online mode for legacy AC800 / Easy series,Inovance HMI integrated diagnostics for HMI-PLC binding faults,Servo-drive panel diagnostics with InoProShop drive-monitor view,EtherCAT slave-firmware update tool,Project compare tool for change tracking

Use the monitoring and diagnostic functions available in your InoProShop / AutoShop version, and record the software, firmware, hardware, workload, and test procedure with every result.

Inovance Structured Text Example for Motor Control

Illustrative Structured Text example for Motor Control using Inovance terminology. Adapt the syntax to your InoProShop / AutoShop release, compile it, and verify it in an isolated test environment before use on equipment.

(* Inovance InoProShop / AutoShop - Motor Control Control *)
(* Structured Text Implementation for Industrial Manufacturing *)
(* On InoProShop projects, conventions follow CODESYS / IEC norms — Pasca *)

PROGRAM PRG_MOTOR_CONTROL_Control

VAR
    (* State Machine Variables *)
    eState : E_MOTOR_CONTROL_States := IDLE;
    bEnable : BOOL := FALSE;
    bFaultActive : BOOL := FALSE;

    (* Timers *)
    tonDebounce : TON;
    tonProcessTimeout : TON;
    tonFeedbackCheck : TON;

    (* Counters *)
    ctuCycleCounter : CTU;

    (* Process Variables *)
    rCurrentsensors : REAL := 0.0;
    rMotorstarters : REAL := 0.0;
    rSetpoint : REAL := 100.0; (* Illustrative value; replace with a reviewed requirement *)
END_VAR

VAR CONSTANT
    (* Industrial Manufacturing Process Parameters *)
    C_DEBOUNCE_TIME : TIME := T#500MS;
    C_PROCESS_TIMEOUT : TIME := T#30S; (* Illustrative value; verify for the process *)
    C_BATCH_SIZE : INT := 50; (* Illustrative value; replace with a reviewed requirement *)
END_VAR

(* Input Conditioning *)
tonDebounce(IN := bStartButton, PT := C_DEBOUNCE_TIME);
bEnable := tonDebounce.Q AND NOT bEmergencyStop AND bSafetyOK;

(* Main State Machine - Pattern: InoProShop state machines typically use  *)
CASE eState OF
    IDLE:
        rMotorstarters := 0.0;
        ctuCycleCounter(RESET := TRUE);
        IF bEnable AND rCurrentsensors > 0.0 THEN
            eState := STARTING;
        END_IF;

    STARTING:
        (* Ramp up output - Gradual start *)
        rMotorstarters := MIN(rMotorstarters + 5.0, rSetpoint);
        IF rMotorstarters >= rSetpoint THEN
            eState := RUNNING;
        END_IF;

    RUNNING:
        (* Motor Control active - Motor control systems use PLCs to start, stop, and *)
        tonProcessTimeout(IN := TRUE, PT := C_PROCESS_TIMEOUT);
        ctuCycleCounter(CU := bCyclePulse, PV := C_BATCH_SIZE);

        IF ctuCycleCounter.Q THEN
            eState := COMPLETE;
        ELSIF tonProcessTimeout.Q THEN
            bFaultActive := TRUE;
            eState := FAULT;
        END_IF;

    COMPLETE:
        rMotorstarters := 0.0;
        (* Log production data - InoProShop on AM600 / H5U supports SD-card logging via library FBs, plus OPC UA streaming for cloud / on-premises historians. Inovance HMIs add CSV logging at HMI tier. AutoShop projects rely on HMI-tier logging exclusively. *)
        eState := IDLE;

    FAULT:
        rMotorstarters := 0.0;
        (* InoProShop alarms are typically defined in the visualisation alarm-configuration page with severity, latching, and acknowledgement behaviour configured per alarm. The runtime maintains active and historical alarm lists. AutoShop projects fall back to M-flag banks with HMI-side alarm logging. *)
        IF bFaultReset AND NOT bEmergencyStop THEN
            bFaultActive := FALSE;
            eState := IDLE;
        END_IF;
END_CASE;

(* Safety Override - Always executes *)
IF bEmergencyStop OR NOT bSafetyOK THEN
    rMotorstarters := 0.0;
    eState := FAULT;
    bFaultActive := TRUE;
END_IF;

END_PROGRAM

Code Explanation:

  • 1.Enumerated state machine (InoProShop state machines typically use IEC SFC steps with action blocks per step, or a state-enum-and-CASE pattern in Structured Text. SFC dominates production-line sequencers; CASE patterns dominate axis-control state and recipe-routing logic. AutoShop projects fall back to FX-style SFC step memory (S0..S511) or D-register integer state.) for clear Motor Control sequence control
  • 2.Constants use clearly marked illustrative values that must be replaced with reviewed project requirements
  • 3.Input conditioning with debounce timer prevents false triggers in industrial environment
  • 4.STARTING state implements soft-start ramp - prevents mechanical shock
  • 5.Process timeout detection flags a possible stuck condition for investigation
  • 6.The final override illustrates a software permissive only; it is not a safety-rated function and must not replace a validated safety system

Best Practices

  • Follow Inovance naming conventions: On InoProShop projects, conventions follow CODESYS / IEC norms — PascalCase for
  • Inovance function design: InoProShop strongly favours function-block reuse via the Library Manager — Inova
  • Data organization: InoProShop uses GVLs and persistent variables for shared data. AutoShop uses D /
  • Structured Text: Use meaningful variable names with consistent naming conventions
  • Structured Text: Initialize all variables at declaration to prevent undefined behavior
  • Structured Text: Use enumerated types for state machines instead of magic numbers
  • Motor Control: Verify motor running with current or speed feedback, not just contactor status
  • Motor Control: Implement minimum off time between starts for motor cooling
  • Motor Control: Add phase loss and phase reversal protection
  • Debug with InoProShop / AutoShop: Use InoProShop's online mode to set breakpoints in POUs and step throu
  • Safety: Proper machine guarding for rotating equipment
  • Use a compatible simulator or isolated test rig to test Motor Control logic before deployment

Common Pitfalls to Avoid

  • Structured Text: Using = instead of := for assignment (= is comparison)
  • Structured Text: Forgetting semicolons at end of statements
  • Structured Text: Integer division truncation - use REAL for decimal results
  • Inovance common error: EtherCAT slave order mismatch after physical re-cabling — slave addressing break
  • Motor Control: Managing starting current within supply limits
  • Motor Control: Coordinating acceleration with driven load requirements
  • Neglecting to validate Current transformers for motor current monitoring leads to control errors
  • Insufficient comments make Structured Text programs unmaintainable over time

Related Certifications

🏆Inovance Certified Engineer
🏆InoProShop / AutoShop training certificates
🏆EV / Lithium Battery automation specialist tracks
🏆Advanced Inovance Programming Certification

Applying Structured Text to Motor Control using Inovance InoProShop / AutoShop requires understanding the platform, the process, and the project's acceptance criteria. This guide has covered implementation structure, an illustrative code example, verification practices, and common pitfalls for a beginner to intermediate Motor Control exercise.

Use the practices outlined here to create a design that can be reviewed and tested. Define performance targets in the project requirements and confirm them with repeatable measurements.

Next Steps:

1. Check Sources: Read the current InoProShop / AutoShop help, controller manual, release notes, and relevant standards
2. Practice Safely: Adapt the example in a simulator or isolated training setup
3. Review: Have the I/O map, state behavior, faults, and recovery steps reviewed
4. Test: Record normal, boundary, fault, restart, and communications test results

Structured Text Foundation:

Structured Text (ST) is a high-level, text-based programming language defined in IEC 61131-3. It resembles Pascal and provides powerful constructs for...

Project duration depends on scope, reviews, hardware availability, software and firmware versions, testing, commissioning, and site constraints. Remember: Verify motor running with current or speed feedback, not just contactor status

For further learning, explore related topics including Recipe management, Fan systems, and Inovance platform-specific features for Motor Control optimization.