Implementing Function Blocks for Pump Control using Inovance InoProShop / AutoShop requires a documented design, applicable standards, and project-specific acceptance criteria. This guide organizes practical checks for code structure, diagnostics, testing, and maintenance.
The example references AM600-family terminology, but model capabilities vary. Verify the controller manual, the installed InoProShop / AutoShop version, and any applicable machinery, process, electrical, or functional-safety requirements for the actual project.
Best practices for Pump Control encompass multiple dimensions: proper handling of 5 sensor types, safe control of 5 different actuators, managing pressure regulation, and ensuring compliance with relevant industry standards. The Function Blocks approach, when properly implemented, provides visual representation of signal flow and good for modular programming, both critical for intermediate projects.
This guide presents a reviewable approach to Inovance Function Blocks programming for Pump Control, covering code organization, documentation, test procedures, and maintenance handoff. The sample logic is educational and must be compiled, simulated, peer-reviewed, and tested against the project's acceptance criteria before use on equipment.
Inovance InoProShop / AutoShop for Pump Control
InoProShop / AutoShop is a programming environment associated with Inovance controller families such as AM600, AM610, H5U. This guide uses Function Blocks terminology from the supplied guide dataset, but controller capabilities and language support can change by model, firmware, software edition, and license.
Verify Before You Start:
- The selected controller supports the required Function Blocks constructs
- The project version matches the installed InoProShop / AutoShop release
- Required communications, motion, safety, and simulation options are licensed
- Firmware and device-description files are compatible with the project
- The vendor manuals used for the design match the exact hardware revision
Application Planning:
For a Pump Control exercise, map the required inputs and outputs before writing logic. The example considers 5 sensor types, including Pressure transmitters, Flow meters, Level sensors, and 5 actuator types.
Control Equipment for Pump Control:
- Centrifugal pumps for high flow applications
- Positive displacement pumps for metering
- Submersible pumps for wet well applications
- Booster pump systems for pressure maintenance
Controller-family references used in this guide include:
- AM600: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide
- AM610: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide
- H5U: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide
- AC800: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide
Hardware Selection Checklist:
- Count local and remote I/O, including planned expansion
- Measure the required task and communications update rates
- Identify memory, data-retention, diagnostics, and cybersecurity requirements
- Treat safety functions as a separate, standards-led design activity
- Confirm lifecycle status, regional availability, licensing, and support
Source and Validation Note:
This page does not represent a vendor certification or a hardware acceptance test. Use current Inovance manuals, release notes, and safety documentation as the authority for product-specific behavior. Validate adapted logic in a simulator or isolated test setup before connecting it to equipment.
Investment Considerations:
For Pump Control projects, compare hardware, software licensing, training, engineering, test equipment, commissioning, spares, and ongoing support. Obtain current pricing and lifecycle information directly from the vendor or an authorized regional supplier.
Understanding Function Blocks for Pump Control
Function Block Diagram (FBD) is a graphical programming language where functions and function blocks are represented as boxes connected by signal lines. Data flows from left to right through the network.
Execution Model:
Blocks execute based on data dependencies - a block executes only when all its inputs are available. Networks execute top to bottom when dependencies allow.
Core Advantages for Pump Control:
- Visual representation of signal flow: Critical for Pump Control when handling intermediate control logic
- Good for modular programming: Critical for Pump Control when handling intermediate control logic
- Reusable components: Critical for Pump Control when handling intermediate control logic
- Excellent for process control: Critical for Pump Control when handling intermediate control logic
- Good for continuous operations: Critical for Pump Control when handling intermediate control logic
Why Function Blocks Fits Pump Control:
Pump Control systems in Water & Wastewater typically involve:
- Sensors: Pressure transmitters for discharge and suction pressure, Flow meters (magnetic, ultrasonic, or vortex), Level transmitters for tank or wet well level
- Actuators: Variable frequency drives (VFDs) for speed control, Motor starters (DOL or soft start), Control valves for flow regulation
- Complexity: Intermediate with challenges including Preventing cavitation at low suction pressure
Control Strategies for Pump Control:
- constant: Maintain fixed speed or output
- pressure: PID control to maintain discharge pressure setpoint
- flow: PID control to maintain flow rate setpoint
Programming Fundamentals in Function Blocks:
StandardBlocks:
- logic: AND, OR, XOR, NOT - Boolean logic operations
- comparison: EQ, NE, LT, GT, LE, GE - Compare values
- math: ADD, SUB, MUL, DIV, MOD - Arithmetic operations
TimersCounters:
- ton: Timer On-Delay - Output turns ON after preset time
- tof: Timer Off-Delay - Output turns OFF after preset time
- tp: Pulse Timer - Output pulses for preset time
Connections:
- wires: Connect output pins to input pins to pass data
- branches: One output can connect to multiple inputs
- feedback: Outputs can feed back to inputs for state machines
Best Practices for Function Blocks:
- Arrange blocks for clear left-to-right data flow
- Use consistent spacing and alignment for readability
- Label all inputs and outputs with meaningful names
- Create custom FBs for frequently repeated logic patterns
- Minimize wire crossings by careful block placement
Common Mistakes to Avoid:
- Creating feedback loops without proper initialization
- Connecting incompatible data types
- Not considering execution order dependencies
- Overcrowding networks making them hard to read
Typical Applications:
1. HVAC control: Directly applicable to Pump Control
2. Temperature control: Related control patterns
3. Flow control: Related control patterns
4. Batch processing: Related control patterns
Understanding these fundamentals prepares you to implement effective Function Blocks solutions for Pump Control using Inovance InoProShop / AutoShop.
Implementing Pump Control with Function Blocks
Pump control systems use PLCs to regulate liquid flow in industrial processes, water treatment, and building services. These systems manage pump operation, protect equipment, optimize energy use, and maintain process parameters.
This walkthrough demonstrates practical implementation using Inovance InoProShop / AutoShop and Function Blocks programming.
System Requirements:
A typical Pump Control implementation includes:
Input Devices (Sensors):
1. Pressure transmitters for discharge and suction pressure: Critical for monitoring system state
2. Flow meters (magnetic, ultrasonic, or vortex): Critical for monitoring system state
3. Level transmitters for tank or wet well level: Critical for monitoring system state
4. Temperature sensors for bearing and motor monitoring: Critical for monitoring system state
5. Vibration sensors for predictive maintenance: Critical for monitoring system state
Output Devices (Actuators):
1. Variable frequency drives (VFDs) for speed control: Primary control output
2. Motor starters (DOL or soft start): Supporting control function
3. Control valves for flow regulation: Supporting control function
4. Isolation valves (actuated for remote operation): Supporting control function
5. Check valves to prevent backflow: Supporting control function
Control Equipment:
- Centrifugal pumps for high flow applications
- Positive displacement pumps for metering
- Submersible pumps for wet well applications
- Booster pump systems for pressure maintenance
Control Strategies for Pump Control:
- constant: Maintain fixed speed or output
- pressure: PID control to maintain discharge pressure setpoint
- flow: PID control to maintain flow rate setpoint
- level: Control tank/wet well level within band
Implementation Steps:
Step 1: Characterize pump curve and system curve
In InoProShop / AutoShop, characterize pump curve and system curve.
Step 2: Size VFD for application (constant torque vs. variable torque)
In InoProShop / AutoShop, size vfd for application (constant torque vs. variable torque).
Step 3: Implement primary control loop (pressure, flow, or level)
In InoProShop / AutoShop, implement primary control loop (pressure, flow, or level).
Step 4: Add pump protection logic (minimum flow, temperature, seal)
In InoProShop / AutoShop, add pump protection logic (minimum flow, temperature, seal).
Step 5: Program lead/lag sequencing with alternation
In InoProShop / AutoShop, program lead/lag sequencing with alternation.
Step 6: Implement soft start/stop ramps for smooth operation
In InoProShop / AutoShop, implement soft start/stop ramps for smooth operation.
Inovance Function Design:
InoProShop strongly favours function-block reuse via the Library Manager — Inovance ships standard libraries for motion, drives, HMI, OPC UA, and industry-specific applications (lithium-battery, EV, elevator). AutoShop reuse is open-coded via P-label subroutines. OEM machine-builders increasingly default to InoProShop / AM600 to access the FB libraries.
Common Challenges and Solutions:
1. Preventing cavitation at low suction pressure
- Solution: Function Blocks addresses this through Visual representation of signal flow.
2. Managing minimum flow requirements
- Solution: Function Blocks addresses this through Good for modular programming.
3. Coordinating VFD speed with system pressure
- Solution: Function Blocks addresses this through Reusable components.
4. Handling pump cycling with varying demand
- Solution: Function Blocks addresses this through Excellent for process control.
Safety Considerations:
- Dry run protection using flow or level monitoring
- Overtemperature protection for motor and bearings
- Overload protection through current monitoring
- Vibration trips for mechanical failure detection
- Emergency stop with proper system depressurization
Performance Metrics:
- Task and I/O timing: Record minimum, average, and maximum values under a defined test load
- Accuracy: Define an acceptable tolerance and compare it with calibrated reference measurements
- Throughput: Count completed cycles over a fixed interval and record rejected or incomplete cycles
- Fault response: Measure detection, safe-state, alarm, and recovery behavior for each test case
- Resource use: Record memory, communications load, and diagnostic-buffer behavior
Inovance Diagnostic Tools:
InoProShop online mode with full POU monitoring and breakpoint debug,EtherCAT diagnostics page with topology and slave status,Trace tool for analogue / motion signal capture,OPC UA server diagnostics page,Modbus communication trace utility,AutoShop online mode for legacy AC800 / Easy series,Inovance HMI integrated diagnostics for HMI-PLC binding faults,Servo-drive panel diagnostics with InoProShop drive-monitor view,EtherCAT slave-firmware update tool,Project compare tool for change tracking
Use the monitoring and diagnostic functions available in your InoProShop / AutoShop version, and record the software, firmware, hardware, workload, and test procedure with every result.
Inovance Function Blocks Example for Pump Control
Illustrative Function Blocks example for Pump Control using Inovance terminology. Adapt the syntax to your InoProShop / AutoShop release, compile it, and verify it in an isolated test environment before use on equipment.
(* Inovance InoProShop / AutoShop - Pump Control Control *)
(* Reusable Function Blocks Implementation *)
(* InoProShop strongly favours function-block reuse via the Lib *)
FUNCTION_BLOCK FB_PUMP_CONTROL_Controller
VAR_INPUT
bEnable : BOOL; (* Enable control *)
bReset : BOOL; (* Fault reset *)
rProcessValue : REAL; (* Pressure transmitters for discharge and suction pressure *)
rSetpoint : REAL := 100.0; (* Illustrative value; replace with a reviewed requirement *)
bEmergencyStop : BOOL; (* Safety input *)
END_VAR
VAR_OUTPUT
rControlOutput : REAL; (* Variable frequency drives (VFDs) for speed control *)
bRunning : BOOL; (* Process active *)
bComplete : BOOL; (* Cycle complete *)
bFault : BOOL; (* Fault status *)
nFaultCode : INT; (* Diagnostic code *)
END_VAR
VAR
(* Internal Function Blocks *)
fbSafety : FB_SafetyMonitor; (* Safety logic *)
fbRamp : FB_RampGenerator; (* Soft start/stop *)
fbPID : FB_PIDController; (* Process control *)
fbDiag : FB_Diagnostics; (* InoProShop alarms are typically defined in the visualisation alarm-configuration page with severity, latching, and acknowledgement behaviour configured per alarm. The runtime maintains active and historical alarm lists. AutoShop projects fall back to M-flag banks with HMI-side alarm logging. *)
(* Internal State *)
eInternalState : E_ControlState;
tonWatchdog : TON;
END_VAR
(* Safety Monitor - Dry run protection using flow or level monitoring *)
fbSafety(
Enable := bEnable,
EmergencyStop := bEmergencyStop,
ProcessValue := rProcessValue,
HighLimit := rSetpoint * 1.2,
LowLimit := rSetpoint * 0.1
);
(* Main Control Logic *)
IF fbSafety.SafeToRun THEN
(* Ramp Generator - Prevents startup surge *)
fbRamp(
Enable := bEnable,
TargetValue := rSetpoint,
RampRate := 20.0, (* Illustrative value; tune and verify for the process *)
CurrentValue => rSetpoint
);
(* PID Controller - Process regulation *)
fbPID(
Enable := fbRamp.InPosition,
ProcessValue := rProcessValue,
Setpoint := fbRamp.CurrentValue,
Kp := 1.0,
Ki := 0.1,
Kd := 0.05,
OutputMin := 0.0,
OutputMax := 100.0
);
rControlOutput := fbPID.Output;
bRunning := TRUE;
bFault := FALSE;
nFaultCode := 0;
ELSE
(* Safe State - Overtemperature protection for motor and bearings *)
rControlOutput := 0.0;
bRunning := FALSE;
bFault := NOT bEnable; (* Only fault if not intentional stop *)
nFaultCode := fbSafety.FaultCode;
END_IF;
(* Diagnostics - InoProShop on AM600 / H5U supports SD-card logging via library FBs, plus OPC UA streaming for cloud / on-premises historians. Inovance HMIs add CSV logging at HMI tier. AutoShop projects rely on HMI-tier logging exclusively. *)
fbDiag(
ProcessRunning := bRunning,
FaultActive := bFault,
ProcessValue := rProcessValue,
ControlOutput := rControlOutput
);
(* Watchdog - Detects frozen control *)
tonWatchdog(IN := bRunning AND NOT fbPID.OutputChanging, PT := T#10S);
IF tonWatchdog.Q THEN
bFault := TRUE;
nFaultCode := 99; (* Watchdog fault *)
END_IF;
(* Reset Logic *)
IF bReset AND NOT bEmergencyStop THEN
bFault := FALSE;
nFaultCode := 0;
fbDiag.ClearAlarms();
END_IF;
END_FUNCTION_BLOCKCode Explanation:
- 1.Encapsulated function block follows InoProShop strongly favours function-blo - reusable across Water & Wastewater projects
- 2.FB_SafetyMonitor illustrates status checks and high/low limits; it is not a certified safety function
- 3.FB_RampGenerator prevents startup issues common in Pump Control systems
- 4.FB_PIDController tuned for Water & Wastewater: Kp=1.0, Ki=0.1
- 5.Watchdog timer illustrates one way to flag an unchanged output for diagnosis
- 6.Diagnostic function block enables InoProShop on AM600 / H5U supports SD-card logging via library FBs, plus OPC UA streaming for cloud / on-premises historians. Inovance HMIs add CSV logging at HMI tier. AutoShop projects rely on HMI-tier logging exclusively. and InoProShop alarms are typically defined in the visualisation alarm-configuration page with severity, latching, and acknowledgement behaviour configured per alarm. The runtime maintains active and historical alarm lists. AutoShop projects fall back to M-flag banks with HMI-side alarm logging.
Best Practices
- ✓Follow Inovance naming conventions: On InoProShop projects, conventions follow CODESYS / IEC norms — PascalCase for
- ✓Inovance function design: InoProShop strongly favours function-block reuse via the Library Manager — Inova
- ✓Data organization: InoProShop uses GVLs and persistent variables for shared data. AutoShop uses D /
- ✓Function Blocks: Arrange blocks for clear left-to-right data flow
- ✓Function Blocks: Use consistent spacing and alignment for readability
- ✓Function Blocks: Label all inputs and outputs with meaningful names
- ✓Pump Control: Use PID with derivative on PV for pressure control
- ✓Pump Control: Implement soft start ramps even with VFD (200-500ms)
- ✓Pump Control: Add flow proving before considering pump operational
- ✓Debug with InoProShop / AutoShop: Use InoProShop's online mode to set breakpoints in POUs and step throu
- ✓Safety: Dry run protection using flow or level monitoring
- ✓Use a compatible simulator or isolated test rig to test Pump Control logic before deployment
Common Pitfalls to Avoid
- ⚠Function Blocks: Creating feedback loops without proper initialization
- ⚠Function Blocks: Connecting incompatible data types
- ⚠Function Blocks: Not considering execution order dependencies
- ⚠Inovance common error: EtherCAT slave order mismatch after physical re-cabling — slave addressing break
- ⚠Pump Control: Preventing cavitation at low suction pressure
- ⚠Pump Control: Managing minimum flow requirements
- ⚠Neglecting to validate Pressure transmitters for discharge and suction pressure leads to control errors
- ⚠Insufficient comments make Function Blocks programs unmaintainable over time
Related Certifications
Applying Function Blocks to Pump Control using Inovance InoProShop / AutoShop requires understanding the platform, the process, and the project's acceptance criteria. This guide has covered implementation structure, an illustrative code example, verification practices, and common pitfalls for a intermediate Pump Control exercise.
Use the practices outlined here to create a design that can be reviewed and tested. Define performance targets in the project requirements and confirm them with repeatable measurements.
Next Steps:
1. Check Sources: Read the current InoProShop / AutoShop help, controller manual, release notes, and relevant standards
2. Practice Safely: Adapt the example in a simulator or isolated training setup
3. Review: Have the I/O map, state behavior, faults, and recovery steps reviewed
4. Test: Record normal, boundary, fault, restart, and communications test results
Function Blocks Foundation:
Function Block Diagram (FBD) is a graphical programming language where functions and function blocks are represented as boxes connected by signal line...
Project duration depends on scope, reviews, hardware availability, software and firmware versions, testing, commissioning, and site constraints. Remember: Use PID with derivative on PV for pressure control
For further learning, explore related topics including Temperature control, Wastewater treatment, and Inovance platform-specific features for Pump Control optimization.