Learn PLCs free
Advanced20 min readUniversal

Unitronics Sequential Function Charts (SFC) for Safety Systems

Learn Sequential Function Charts (SFC) programming for Safety Systems using Unitronics VisiLogic / UniLogic. Includes code examples, best practices, and step-by-step implementation guide for Universal applications.

πŸ’»
Platform
VisiLogic / UniLogic
πŸ“Š
Complexity
Advanced
⏱️
Project Duration
4-8 weeks

Implementing Sequential Function Charts (SFC) for Safety Systems using Unitronics VisiLogic / UniLogic requires translating theory into working code that performs reliably in production. This hands-on guide focuses on practical implementation steps, real code examples, and the pragmatic decisions that make the difference between successful and problematic Safety Systems deployments.

Unitronics's platform serves Moderate - US small-integrator market, OEM machines, building automation, providing the proven foundation for Safety Systems implementations. The VisiLogic / UniLogic environment supports 3 programming languages, with Sequential Function Charts (SFC) being particularly effective for Safety Systems because batch processes, step-by-step operations, state machines, and complex sequential control. Practical implementation requires understanding not just language syntax, but how Unitronics's execution model handles 5 sensor inputs and 4 actuator outputs in real-time.

Real Safety Systems projects in Universal face practical challenges including safety integrity level (sil) compliance, redundancy requirements, and integration with existing systems. Success requires balancing perfect for sequential processes against limited to sequential operations, while meeting 4-8 weeks project timelines typical for Safety Systems implementations.

This guide provides step-by-step implementation guidance, complete working examples tested on Jazz 2, practical design patterns, and real-world troubleshooting scenarios. You'll learn the pragmatic approaches that experienced integrators use to deliver reliable Safety Systems systems on schedule and within budget.

Unitronics VisiLogic / UniLogic for Safety Systems

Unitronics takes a distinctive approach to PLC programming: every controller ships with an integrated colour touchscreen HMI, and the development tool handles PLC logic and HMI design in a single workspace. VisiLogic is the legacy tool for the Vision, Samba, and Jazz product families; UniLogic is the current-generation environment for the UniStream line. Both are free to download and include a complete built-in simulator covering PLC logic, HMI screens, alarms, recipes, and data tables β€” the sim...

Platform Strengths for Safety Systems:

  • Combined PLC + HMI in one unit reduces panel cost

  • Free VisiLogic and UniLogic IDEs

  • Built-in simulator with both PLC and HMI simulation

  • Strong US small-integrator community


Unique ${brand.software} Features:

  • Combined PLC + HMI in one unit across Jazz, Samba, Vision, and UniStream

  • Free VisiLogic (legacy) and UniLogic (current) IDEs

  • Built-in simulator covering PLC logic, HMI, alarms, data tables, and recipes

  • Integrated data sampling and trend logging without separate SCADA


Key Capabilities:

The VisiLogic / UniLogic environment excels at Safety Systems applications through its combined plc + hmi in one unit reduces panel cost. This is particularly valuable when working with the 5 sensor types typically found in Safety Systems systems, including Safety light curtains, Emergency stop buttons, Safety door switches.

Control Equipment for Safety Systems:

  • Safety PLCs (fail-safe controllers)

  • Safety relays (configurable or fixed)

  • Safety I/O modules with diagnostics

  • Safety network protocols (PROFIsafe, CIP Safety)


Unitronics's controller families for Safety Systems include:

  • Jazz 2: Suitable for advanced Safety Systems applications

  • Samba 7": Suitable for advanced Safety Systems applications

  • Vision V350: Suitable for advanced Safety Systems applications

  • Vision V570: Suitable for advanced Safety Systems applications

Hardware Selection Guidance:

CPU selection across Unitronics ranges from the Jazz 2 micro series (tiny applications, basic motor control, simple process monitoring with 10-20 I/O) through Samba 7" (small machine control with touchscreen HMI), Vision V350/V570 (medium machinery with larger HMI), and UniStream 7" / 15.6" (flagship combined PLC+HMI for mid-to-high complexity applications with advanced features like UniCloud, cel...

Industry Recognition:

Moderate - US small-integrator market, OEM machines, building automation. Unitronics' combined PLC+HMI controllers are uncommon in high-volume automotive manufacturing but appear in automotive tier-2 and tier-3 supplier shops, single-machine workcells, and after-market test fixtures. The cost advantage and single-unit PLC+HMI approach makes Unitronics attractive for small...

Investment Considerations:

With $$ pricing, Unitronics positions itself in the mid-range segment. For Safety Systems projects requiring advanced skill levels and 4-8 weeks development time, the total investment includes hardware, software licensing, training, and ongoing support.

Understanding Sequential Function Charts (SFC) for Safety Systems

Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by transitions, ideal for batch processes and machine sequences.

Execution Model:

Only active steps execute their actions. Transitions define conditions for moving between steps. Multiple steps can be active simultaneously in parallel branches.

Core Advantages for Safety Systems:

  • Perfect for sequential processes: Critical for Safety Systems when handling advanced control logic

  • Clear visualization of process flow: Critical for Safety Systems when handling advanced control logic

  • Easy to understand process steps: Critical for Safety Systems when handling advanced control logic

  • Good for batch operations: Critical for Safety Systems when handling advanced control logic

  • Simplifies complex sequences: Critical for Safety Systems when handling advanced control logic


Why Sequential Function Charts (SFC) Fits Safety Systems:

Safety Systems systems in Universal typically involve:

  • Sensors: Emergency stop buttons (Category 0 or 1 stop), Safety light curtains (Type 2 or Type 4), Safety laser scanners for zone detection

  • Actuators: Safety contactors (mirror contact type), Safe torque off (STO) drives, Safety brake modules

  • Complexity: Advanced with challenges including Achieving required safety level with practical architecture


Programming Fundamentals in Sequential Function Charts (SFC):

Steps:
- initialStep: Double-bordered box - starting point of sequence, active on program start
- normalStep: Single-bordered box - becomes active when preceding transition fires
- actions: Associated code that executes while step is active

Transitions:
- condition: Boolean expression that must be TRUE to advance
- firing: Transition fires when preceding step is active AND condition is TRUE
- priority: In selective branches, transitions are evaluated in defined order

ActionQualifiers:
- N: Non-stored - executes while step is active
- S: Set - sets output TRUE on step entry, remains TRUE
- R: Reset - sets output FALSE on step entry

Best Practices for Sequential Function Charts (SFC):

  • Start with a clear process flow diagram before implementing SFC

  • Use descriptive step names indicating what happens (e.g., Filling, Heating)

  • Keep transition conditions simple - complex logic goes in action code

  • Implement timeout transitions to prevent stuck sequences

  • Always provide a path back to initial step for reset/restart


Common Mistakes to Avoid:

  • Forgetting to include stop/abort transitions for emergency handling

  • Creating deadlocks where no transition can fire

  • Not handling the case where transition conditions never become TRUE

  • Using S (Set) actions without corresponding R (Reset) actions


Typical Applications:

1. Bottle filling: Directly applicable to Safety Systems
2. Assembly sequences: Related control patterns
3. Material handling: Related control patterns
4. Batch mixing: Related control patterns

Understanding these fundamentals prepares you to implement effective Sequential Function Charts (SFC) solutions for Safety Systems using Unitronics VisiLogic / UniLogic.

Implementing Safety Systems with Sequential Function Charts (SFC)

Safety system control uses safety-rated PLCs and components to protect personnel and equipment from hazardous conditions. These systems implement safety functions per IEC 62443 and ISO 13849 standards with redundancy and diagnostics.

This walkthrough demonstrates practical implementation using Unitronics VisiLogic / UniLogic and Sequential Function Charts (SFC) programming.

System Requirements:

A typical Safety Systems implementation includes:

Input Devices (Sensors):
1. Emergency stop buttons (Category 0 or 1 stop): Critical for monitoring system state
2. Safety light curtains (Type 2 or Type 4): Critical for monitoring system state
3. Safety laser scanners for zone detection: Critical for monitoring system state
4. Safety interlock switches (tongue, hinged, trapped key): Critical for monitoring system state
5. Safety mats and edges: Critical for monitoring system state

Output Devices (Actuators):
1. Safety contactors (mirror contact type): Primary control output
2. Safe torque off (STO) drives: Supporting control function
3. Safety brake modules: Supporting control function
4. Lock-out valve manifolds: Supporting control function
5. Safety relay outputs: Supporting control function

Control Equipment:

  • Safety PLCs (fail-safe controllers)

  • Safety relays (configurable or fixed)

  • Safety I/O modules with diagnostics

  • Safety network protocols (PROFIsafe, CIP Safety)


Control Strategies for Safety Systems:

1. Primary Control: Safety-rated PLC programming for personnel protection, emergency stops, and safety interlocks per IEC 61508/61511.
2. Safety Interlocks: Preventing Safety integrity level (SIL) compliance
3. Error Recovery: Handling Redundancy requirements

Implementation Steps:

Step 1: Perform hazard analysis and risk assessment

In VisiLogic / UniLogic, perform hazard analysis and risk assessment.

Step 2: Determine required safety level (SIL/PL) for each function

In VisiLogic / UniLogic, determine required safety level (sil/pl) for each function.

Step 3: Select certified safety components meeting requirements

In VisiLogic / UniLogic, select certified safety components meeting requirements.

Step 4: Design safety circuit architecture per category requirements

In VisiLogic / UniLogic, design safety circuit architecture per category requirements.

Step 5: Implement safety logic in certified safety PLC/relay

In VisiLogic / UniLogic, implement safety logic in certified safety plc/relay.

Step 6: Add diagnostics and proof test provisions

In VisiLogic / UniLogic, add diagnostics and proof test provisions.


Unitronics Function Design:

Function block design in Unitronics uses user-defined FBs in UniLogic (more limited in VisiLogic). Extensive vendor-provided helper FBs cover common tasks (PID, motion, communication, HMI utilities). OEM machine builders typically maintain private FB libraries for their common machine patterns, though code reuse is less mature than in mainstream PLC ecosystems.

Common Challenges and Solutions:

1. Achieving required safety level with practical architecture

  • Solution: Sequential Function Charts (SFC) addresses this through Perfect for sequential processes.


2. Managing nuisance trips while maintaining safety

  • Solution: Sequential Function Charts (SFC) addresses this through Clear visualization of process flow.


3. Integrating safety with production efficiency

  • Solution: Sequential Function Charts (SFC) addresses this through Easy to understand process steps.


4. Documenting compliance with multiple standards

  • Solution: Sequential Function Charts (SFC) addresses this through Good for batch operations.


Safety Considerations:

  • Use only certified safety components and PLCs

  • Implement dual-channel monitoring per category requirements

  • Add diagnostic coverage to detect latent faults

  • Design for fail-safe operation (de-energize to trip)

  • Provide regular proof testing of safety functions


Performance Metrics:

  • Scan Time: Optimize for 5 inputs and 4 outputs

  • Memory Usage: Efficient data structures for Jazz 2 capabilities

  • Response Time: Meeting Universal requirements for Safety Systems

Unitronics Diagnostic Tools:

UniLogic (current) and VisiLogic (legacy) integrated debuggers with breakpoints,Built-in simulator covering PLC logic, HMI screens, alarms, recipes, and data tables,Web visualisation for UniStream β€” remote HMI viewing without additional software,SD card logging with PC-side export tools for offline trend analysis,Modbus RTU/TCP transaction logging built into the IDE,Controller status monitor β€” CPU load, scan time, memory usage,HMI event logger capturing operator actions for audit purposes,CAN bus diagnostic tools for CANopen-equipped models,Remote support tool β€” Unitronics' own screen-sharing for technical support,User community forum with active troubleshooting discussions

Unitronics's VisiLogic / UniLogic provides tools for performance monitoring and optimization, essential for achieving the 4-8 weeks development timeline while maintaining code quality.

Unitronics Sequential Function Charts (SFC) Example for Safety Systems

Complete working example demonstrating Sequential Function Charts (SFC) implementation for Safety Systems using Unitronics VisiLogic / UniLogic. Follows Unitronics naming conventions. Tested on Jazz 2 hardware.

// Unitronics VisiLogic / UniLogic - Safety Systems Control
// Sequential Function Charts (SFC) Implementation for Universal
// Unitronics projects use IDE-managed tag names rather than ra

// ============================================
// Variable Declarations
// ============================================
VAR
    bEnable : BOOL := FALSE;
    bEmergencyStop : BOOL := FALSE;
    rSafetylightcurtains : REAL;
    rSafetyrelays : REAL;
END_VAR

// ============================================
// Input Conditioning - Emergency stop buttons (Category 0 or 1 stop)
// ============================================
// Standard input processing
IF rSafetylightcurtains > 0.0 THEN
    bEnable := TRUE;
END_IF;

// ============================================
// Safety Interlock - Use only certified safety components and PLCs
// ============================================
IF bEmergencyStop THEN
    rSafetyrelays := 0.0;
    bEnable := FALSE;
END_IF;

// ============================================
// Main Safety Systems Control Logic
// ============================================
IF bEnable AND NOT bEmergencyStop THEN
    // Safety system control uses safety-rated PLCs and components 
    rSafetyrelays := rSafetylightcurtains * 1.0;

    // Process monitoring
    // Add specific control logic here
ELSE
    rSafetyrelays := 0.0;
END_IF;

Code Explanation:

  • 1.Sequential Function Charts (SFC) structure optimized for Safety Systems in Universal applications
  • 2.Input conditioning handles Emergency stop buttons (Category 0 or 1 stop) signals
  • 3.Safety interlock ensures Use only certified safety components and PLCs always takes priority
  • 4.Main control implements Safety system control uses safety-rated
  • 5.Code runs every scan cycle on Jazz 2 (typically 5-20ms)

Best Practices

  • βœ“Follow Unitronics naming conventions: Unitronics projects use IDE-managed tag names rather than raw memory addressing.
  • βœ“Unitronics function design: Function block design in Unitronics uses user-defined FBs in UniLogic (more limi
  • βœ“Data organization: Unitronics uses its own tag database concept rather than IEC-standard data block
  • βœ“Sequential Function Charts (SFC): Start with a clear process flow diagram before implementing SFC
  • βœ“Sequential Function Charts (SFC): Use descriptive step names indicating what happens (e.g., Filling, Heating)
  • βœ“Sequential Function Charts (SFC): Keep transition conditions simple - complex logic goes in action code
  • βœ“Safety Systems: Keep safety logic simple and auditable
  • βœ“Safety Systems: Use certified function blocks from safety PLC vendor
  • βœ“Safety Systems: Implement cross-monitoring between channels
  • βœ“Debug with VisiLogic / UniLogic: Use the built-in simulator to reproduce issues before hardware visit
  • βœ“Safety: Use only certified safety components and PLCs
  • βœ“Use VisiLogic / UniLogic simulation tools to test Safety Systems logic before deployment

Common Pitfalls to Avoid

  • ⚠Sequential Function Charts (SFC): Forgetting to include stop/abort transitions for emergency handling
  • ⚠Sequential Function Charts (SFC): Creating deadlocks where no transition can fire
  • ⚠Sequential Function Charts (SFC): Not handling the case where transition conditions never become TRUE
  • ⚠Unitronics common error: VisiLogic-to-UniLogic migration issues β€” not all projects convert cleanly
  • ⚠Safety Systems: Achieving required safety level with practical architecture
  • ⚠Safety Systems: Managing nuisance trips while maintaining safety
  • ⚠Neglecting to validate Emergency stop buttons (Category 0 or 1 stop) leads to control errors
  • ⚠Insufficient comments make Sequential Function Charts (SFC) programs unmaintainable over time

Related Certifications

πŸ†Unitronics Certified Integrator
πŸ†UniLogic Developer Training

Mastering Sequential Function Charts (SFC) for Safety Systems applications using Unitronics VisiLogic / UniLogic requires understanding both the platform's capabilities and the specific demands of Universal. This guide has provided comprehensive coverage of implementation strategies, working code examples, best practices, and common pitfalls to help you succeed with advanced Safety Systems projects.

Unitronics's 1% market share and moderate - us small-integrator market, oem machines, building automation demonstrate the platform's capability for demanding applications. The platform excels in Universal applications where Safety Systems reliability is critical.

By following the practices outlined in this guideβ€”from proper program structure and Sequential Function Charts (SFC) best practices to Unitronics-specific optimizationsβ€”you can deliver reliable Safety Systems systems that meet Universal requirements.

Next Steps for Professional Development:

1. Certification: Pursue Unitronics Certified Integrator to validate your Unitronics expertise
2. Advanced Training: Consider UniLogic Developer Training for specialized Universal applications
3. Hands-on Practice: Build Safety Systems projects using Jazz 2 hardware
4. Stay Current: Follow VisiLogic / UniLogic updates and new Sequential Function Charts (SFC) features

Sequential Function Charts (SFC) Foundation:

Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by tran...

The 4-8 weeks typical timeline for Safety Systems projects will decrease as you gain experience with these patterns and techniques. Remember: Keep safety logic simple and auditable

For further learning, explore related topics including Assembly sequences, Emergency stop systems, and Unitronics platform-specific features for Safety Systems optimization.