Implementing Sequential Function Charts (SFC) for Safety Systems using Unitronics VisiLogic / UniLogic requires translating a control narrative into code, tests, and commissioning checks. This hands-on guide focuses on practical implementation steps, an illustrative code example, and decisions that should be recorded during design review.
The guide uses VisiLogic / UniLogic terminology and Sequential Function Charts (SFC) because batch processes, step-by-step operations, state machines, and complex sequential control. Confirm language support for the selected controller and software release, then map the example's 5 sensor inputs and 4 actuator outputs to the project's reviewed I/O list.
Real Safety Systems projects in Universal face practical challenges including safety integrity level (sil) compliance, redundancy requirements, and integration with existing systems. Success requires balancing perfect for sequential processes against limited to sequential operations, while meeting 4-8 weeks project timelines typical for Safety Systems implementations.
This guide provides step-by-step implementation guidance, an illustrative example, practical design patterns, and troubleshooting scenarios. Compile and test the adapted logic in an isolated environment, verify fail-safe behavior with the responsible controls and safety reviewers, and complete site acceptance checks before production use.
Unitronics VisiLogic / UniLogic for Safety Systems
VisiLogic / UniLogic is a programming environment associated with Unitronics controller families such as Jazz 2, Samba 7", Vision V350. This guide uses Sequential Function Charts (SFC) terminology from the supplied guide dataset, but controller capabilities and language support can change by model, firmware, software edition, and license.
Verify Before You Start:
- The selected controller supports the required Sequential Function Charts (SFC) constructs
- The project version matches the installed VisiLogic / UniLogic release
- Required communications, motion, safety, and simulation options are licensed
- Firmware and device-description files are compatible with the project
- The vendor manuals used for the design match the exact hardware revision
Application Planning:
For a Safety Systems exercise, map the required inputs and outputs before writing logic. The example considers 5 sensor types, including Safety light curtains, Emergency stop buttons, Safety door switches, and 4 actuator types.
Control Equipment for Safety Systems:
- Safety PLCs (fail-safe controllers)
- Safety relays (configurable or fixed)
- Safety I/O modules with diagnostics
- Safety network protocols (PROFIsafe, CIP Safety)
Controller-family references used in this guide include:
- Jazz 2: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide
- Samba 7": Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide
- Vision V350: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide
- Vision V570: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide
Hardware Selection Checklist:
- Count local and remote I/O, including planned expansion
- Measure the required task and communications update rates
- Identify memory, data-retention, diagnostics, and cybersecurity requirements
- Treat safety functions as a separate, standards-led design activity
- Confirm lifecycle status, regional availability, licensing, and support
Source and Validation Note:
This page does not represent a vendor certification or a hardware acceptance test. Use current Unitronics manuals, release notes, and safety documentation as the authority for product-specific behavior. Validate adapted logic in a simulator or isolated test setup before connecting it to equipment.
Investment Considerations:
For Safety Systems projects, compare hardware, software licensing, training, engineering, test equipment, commissioning, spares, and ongoing support. Obtain current pricing and lifecycle information directly from the vendor or an authorized regional supplier.
Understanding Sequential Function Charts (SFC) for Safety Systems
Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by transitions, ideal for batch processes and machine sequences.
Execution Model:
Only active steps execute their actions. Transitions define conditions for moving between steps. Multiple steps can be active simultaneously in parallel branches.
Core Advantages for Safety Systems:
- Perfect for sequential processes: Critical for Safety Systems when handling advanced control logic
- Clear visualization of process flow: Critical for Safety Systems when handling advanced control logic
- Easy to understand process steps: Critical for Safety Systems when handling advanced control logic
- Good for batch operations: Critical for Safety Systems when handling advanced control logic
- Simplifies complex sequences: Critical for Safety Systems when handling advanced control logic
Why Sequential Function Charts (SFC) Fits Safety Systems:
Safety Systems systems in Universal typically involve:
- Sensors: Emergency stop buttons (Category 0 or 1 stop), Safety light curtains (Type 2 or Type 4), Safety laser scanners for zone detection
- Actuators: Safety contactors (mirror contact type), Safe torque off (STO) drives, Safety brake modules
- Complexity: Advanced with challenges including Achieving required safety level with practical architecture
Programming Fundamentals in Sequential Function Charts (SFC):
Steps:
- initialStep: Double-bordered box - starting point of sequence, active on program start
- normalStep: Single-bordered box - becomes active when preceding transition fires
- actions: Associated code that executes while step is active
Transitions:
- condition: Boolean expression that must be TRUE to advance
- firing: Transition fires when preceding step is active AND condition is TRUE
- priority: In selective branches, transitions are evaluated in defined order
ActionQualifiers:
- N: Non-stored - executes while step is active
- S: Set - sets output TRUE on step entry, remains TRUE
- R: Reset - sets output FALSE on step entry
Best Practices for Sequential Function Charts (SFC):
- Start with a clear process flow diagram before implementing SFC
- Use descriptive step names indicating what happens (e.g., Filling, Heating)
- Keep transition conditions simple - complex logic goes in action code
- Implement timeout transitions to prevent stuck sequences
- Always provide a path back to initial step for reset/restart
Common Mistakes to Avoid:
- Forgetting to include stop/abort transitions for emergency handling
- Creating deadlocks where no transition can fire
- Not handling the case where transition conditions never become TRUE
- Using S (Set) actions without corresponding R (Reset) actions
Typical Applications:
1. Bottle filling: Directly applicable to Safety Systems
2. Assembly sequences: Related control patterns
3. Material handling: Related control patterns
4. Batch mixing: Related control patterns
Understanding these fundamentals prepares you to implement effective Sequential Function Charts (SFC) solutions for Safety Systems using Unitronics VisiLogic / UniLogic.
Implementing Safety Systems with Sequential Function Charts (SFC)
Safety system control uses safety-rated PLCs and components to protect personnel and equipment from hazardous conditions. These systems implement safety functions per IEC 62443 and ISO 13849 standards with redundancy and diagnostics.
This walkthrough demonstrates practical implementation using Unitronics VisiLogic / UniLogic and Sequential Function Charts (SFC) programming.
System Requirements:
A typical Safety Systems implementation includes:
Input Devices (Sensors):
1. Emergency stop buttons (Category 0 or 1 stop): Critical for monitoring system state
2. Safety light curtains (Type 2 or Type 4): Critical for monitoring system state
3. Safety laser scanners for zone detection: Critical for monitoring system state
4. Safety interlock switches (tongue, hinged, trapped key): Critical for monitoring system state
5. Safety mats and edges: Critical for monitoring system state
Output Devices (Actuators):
1. Safety contactors (mirror contact type): Primary control output
2. Safe torque off (STO) drives: Supporting control function
3. Safety brake modules: Supporting control function
4. Lock-out valve manifolds: Supporting control function
5. Safety relay outputs: Supporting control function
Control Equipment:
- Safety PLCs (fail-safe controllers)
- Safety relays (configurable or fixed)
- Safety I/O modules with diagnostics
- Safety network protocols (PROFIsafe, CIP Safety)
Control Strategies for Safety Systems:
1. Primary Control: Safety-rated PLC programming for personnel protection, emergency stops, and safety interlocks per IEC 61508/61511.
2. Safety Interlocks: Preventing Safety integrity level (SIL) compliance
3. Error Recovery: Handling Redundancy requirements
Implementation Steps:
Step 1: Perform hazard analysis and risk assessment
In VisiLogic / UniLogic, perform hazard analysis and risk assessment.
Step 2: Determine required safety level (SIL/PL) for each function
In VisiLogic / UniLogic, determine required safety level (sil/pl) for each function.
Step 3: Select certified safety components meeting requirements
In VisiLogic / UniLogic, select certified safety components meeting requirements.
Step 4: Design safety circuit architecture per category requirements
In VisiLogic / UniLogic, design safety circuit architecture per category requirements.
Step 5: Implement safety logic in certified safety PLC/relay
In VisiLogic / UniLogic, implement safety logic in certified safety plc/relay.
Step 6: Add diagnostics and proof test provisions
In VisiLogic / UniLogic, add diagnostics and proof test provisions.
Unitronics Function Design:
Function block design in Unitronics uses user-defined FBs in UniLogic (more limited in VisiLogic). Extensive vendor-provided helper FBs cover common tasks (PID, motion, communication, HMI utilities). OEM machine builders typically maintain private FB libraries for their common machine patterns, though code reuse is less mature than in mainstream PLC ecosystems.
Common Challenges and Solutions:
1. Achieving required safety level with practical architecture
- Solution: Sequential Function Charts (SFC) addresses this through Perfect for sequential processes.
2. Managing nuisance trips while maintaining safety
- Solution: Sequential Function Charts (SFC) addresses this through Clear visualization of process flow.
3. Integrating safety with production efficiency
- Solution: Sequential Function Charts (SFC) addresses this through Easy to understand process steps.
4. Documenting compliance with multiple standards
- Solution: Sequential Function Charts (SFC) addresses this through Good for batch operations.
Safety Considerations:
- Use only certified safety components and PLCs
- Implement dual-channel monitoring per category requirements
- Add diagnostic coverage to detect latent faults
- Design for fail-safe operation (de-energize to trip)
- Provide regular proof testing of safety functions
Performance Metrics:
- Task and I/O timing: Record minimum, average, and maximum values under a defined test load
- Accuracy: Define an acceptable tolerance and compare it with calibrated reference measurements
- Throughput: Count completed cycles over a fixed interval and record rejected or incomplete cycles
- Fault response: Measure detection, safe-state, alarm, and recovery behavior for each test case
- Resource use: Record memory, communications load, and diagnostic-buffer behavior
Unitronics Diagnostic Tools:
UniLogic (current) and VisiLogic (legacy) integrated debuggers with breakpoints,Built-in simulator covering PLC logic, HMI screens, alarms, recipes, and data tables,Web visualisation for UniStream — remote HMI viewing without additional software,SD card logging with PC-side export tools for offline trend analysis,Modbus RTU/TCP transaction logging built into the IDE,Controller status monitor — CPU load, scan time, memory usage,HMI event logger capturing operator actions for audit purposes,CAN bus diagnostic tools for CANopen-equipped models,Remote support tool — Unitronics' own screen-sharing for technical support,User community forum with active troubleshooting discussions
Use the monitoring and diagnostic functions available in your VisiLogic / UniLogic version, and record the software, firmware, hardware, workload, and test procedure with every result.
Unitronics Sequential Function Charts (SFC) Example for Safety Systems
Illustrative Sequential Function Charts (SFC) example for Safety Systems using Unitronics terminology. Adapt the syntax to your VisiLogic / UniLogic release, compile it, and verify it in an isolated test environment before use on equipment.
// Unitronics VisiLogic / UniLogic - Safety Systems Control
// Sequential Function Charts (SFC) Implementation for Universal
// Unitronics projects use IDE-managed tag names rather than ra
// ============================================
// Variable Declarations
// ============================================
VAR
bEnable : BOOL := FALSE;
bEmergencyStop : BOOL := FALSE;
rSafetylightcurtains : REAL;
rSafetyrelays : REAL;
END_VAR
// ============================================
// Input Conditioning - Emergency stop buttons (Category 0 or 1 stop)
// ============================================
// Standard input processing
IF rSafetylightcurtains > 0.0 THEN
bEnable := TRUE;
END_IF;
// ============================================
// Safety Interlock - Use only certified safety components and PLCs
// ============================================
IF bEmergencyStop THEN
rSafetyrelays := 0.0;
bEnable := FALSE;
END_IF;
// ============================================
// Main Safety Systems Control Logic
// ============================================
IF bEnable AND NOT bEmergencyStop THEN
// Safety system control uses safety-rated PLCs and components
rSafetyrelays := rSafetylightcurtains * 1.0; (* Illustrative scaling only *)
// Process monitoring
// Add specific control logic here
ELSE
rSafetyrelays := 0.0;
END_IF;Code Explanation:
- 1.Sequential Function Charts (SFC) structure organized for a Safety Systems training example
- 2.Input conditioning handles Emergency stop buttons (Category 0 or 1 stop) signals
- 3.Safety interlock ensures Use only certified safety components and PLCs always takes priority
- 4.Main control implements Safety system control uses safety-rated
- 5.Adapt the scan-cycle assumptions to the selected Jazz 2 task configuration and verify them by measurement
Best Practices
- ✓Follow Unitronics naming conventions: Unitronics projects use IDE-managed tag names rather than raw memory addressing.
- ✓Unitronics function design: Function block design in Unitronics uses user-defined FBs in UniLogic (more limi
- ✓Data organization: Unitronics uses its own tag database concept rather than IEC-standard data block
- ✓Sequential Function Charts (SFC): Start with a clear process flow diagram before implementing SFC
- ✓Sequential Function Charts (SFC): Use descriptive step names indicating what happens (e.g., Filling, Heating)
- ✓Sequential Function Charts (SFC): Keep transition conditions simple - complex logic goes in action code
- ✓Safety Systems: Keep safety logic simple and auditable
- ✓Safety Systems: Use certified function blocks from safety PLC vendor
- ✓Safety Systems: Implement cross-monitoring between channels
- ✓Debug with VisiLogic / UniLogic: Use the built-in simulator to reproduce issues before hardware visit
- ✓Safety: Use only certified safety components and PLCs
- ✓Use a compatible simulator or isolated test rig to test Safety Systems logic before deployment
Common Pitfalls to Avoid
- ⚠Sequential Function Charts (SFC): Forgetting to include stop/abort transitions for emergency handling
- ⚠Sequential Function Charts (SFC): Creating deadlocks where no transition can fire
- ⚠Sequential Function Charts (SFC): Not handling the case where transition conditions never become TRUE
- ⚠Unitronics common error: VisiLogic-to-UniLogic migration issues — not all projects convert cleanly
- ⚠Safety Systems: Achieving required safety level with practical architecture
- ⚠Safety Systems: Managing nuisance trips while maintaining safety
- ⚠Neglecting to validate Emergency stop buttons (Category 0 or 1 stop) leads to control errors
- ⚠Insufficient comments make Sequential Function Charts (SFC) programs unmaintainable over time
Related Certifications
Applying Sequential Function Charts (SFC) to Safety Systems using Unitronics VisiLogic / UniLogic requires understanding the platform, the process, and the project's acceptance criteria. This guide has covered implementation structure, an illustrative code example, verification practices, and common pitfalls for a advanced Safety Systems exercise.
Use the practices outlined here to create a design that can be reviewed and tested. Define performance targets in the project requirements and confirm them with repeatable measurements.
Next Steps:
1. Check Sources: Read the current VisiLogic / UniLogic help, controller manual, release notes, and relevant standards
2. Practice Safely: Adapt the example in a simulator or isolated training setup
3. Review: Have the I/O map, state behavior, faults, and recovery steps reviewed
4. Test: Record normal, boundary, fault, restart, and communications test results
Sequential Function Charts (SFC) Foundation:
Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by tran...
Project duration depends on scope, reviews, hardware availability, software and firmware versions, testing, commissioning, and site constraints. Remember: Keep safety logic simple and auditable
For further learning, explore related topics including Assembly sequences, Emergency stop systems, and Unitronics platform-specific features for Safety Systems optimization.