Learn PLCs free
Intermediate20 min readPackaging

Unitronics Function Blocks for Bottle Filling

Learn Function Blocks programming for Bottle Filling using Unitronics VisiLogic / UniLogic. Includes code examples, best practices, and step-by-step implementation guide for Packaging applications.

💻
Platform
VisiLogic / UniLogic
📊
Complexity
Intermediate to Advanced
⏱️
Project Duration
3-6 weeks

Implementing Function Blocks for Bottle Filling using Unitronics VisiLogic / UniLogic requires translating a control narrative into code, tests, and commissioning checks. This hands-on guide focuses on practical implementation steps, an illustrative code example, and decisions that should be recorded during design review.

The guide uses VisiLogic / UniLogic terminology and Function Blocks because process control, continuous operations, modular programming, and signal flow visualization. Confirm language support for the selected controller and software release, then map the example's 5 sensor inputs and 5 actuator outputs to the project's reviewed I/O list.

Real Bottle Filling projects in Packaging face practical challenges including precise fill volume, high-speed operation, and integration with existing systems. Success requires balancing visual representation of signal flow against can become cluttered with complex logic, while meeting 3-6 weeks project timelines typical for Bottle Filling implementations.

This guide provides step-by-step implementation guidance, an illustrative example, practical design patterns, and troubleshooting scenarios. Compile and test the adapted logic in an isolated environment, verify fail-safe behavior with the responsible controls and safety reviewers, and complete site acceptance checks before production use.

Unitronics VisiLogic / UniLogic for Bottle Filling

VisiLogic / UniLogic is a programming environment associated with Unitronics controller families such as Jazz 2, Samba 7", Vision V350. This guide uses Function Blocks terminology from the supplied guide dataset, but controller capabilities and language support can change by model, firmware, software edition, and license.

Verify Before You Start:

  • The selected controller supports the required Function Blocks constructs

  • The project version matches the installed VisiLogic / UniLogic release

  • Required communications, motion, safety, and simulation options are licensed

  • Firmware and device-description files are compatible with the project

  • The vendor manuals used for the design match the exact hardware revision


Application Planning:

For a Bottle Filling exercise, map the required inputs and outputs before writing logic. The example considers 5 sensor types, including Level sensors, Flow meters, Pressure sensors, and 5 actuator types.

Control Equipment for Bottle Filling:

  • Filling nozzles (gravity, pressure, vacuum)

  • Product tanks with level control

  • CIP (clean-in-place) systems

  • Cap feeding and sorting equipment


Controller-family references used in this guide include:

  • Jazz 2: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide

  • Samba 7": Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide

  • Vision V350: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide

  • Vision V570: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide


Hardware Selection Checklist:

  • Count local and remote I/O, including planned expansion

  • Measure the required task and communications update rates

  • Identify memory, data-retention, diagnostics, and cybersecurity requirements

  • Treat safety functions as a separate, standards-led design activity

  • Confirm lifecycle status, regional availability, licensing, and support


Source and Validation Note:

This page does not represent a vendor certification or a hardware acceptance test. Use current Unitronics manuals, release notes, and safety documentation as the authority for product-specific behavior. Validate adapted logic in a simulator or isolated test setup before connecting it to equipment.

Investment Considerations:

For Bottle Filling projects, compare hardware, software licensing, training, engineering, test equipment, commissioning, spares, and ongoing support. Obtain current pricing and lifecycle information directly from the vendor or an authorized regional supplier.

Understanding Function Blocks for Bottle Filling

Function Block Diagram (FBD) is a graphical programming language where functions and function blocks are represented as boxes connected by signal lines. Data flows from left to right through the network.

Execution Model:

Blocks execute based on data dependencies - a block executes only when all its inputs are available. Networks execute top to bottom when dependencies allow.

Core Advantages for Bottle Filling:

  • Visual representation of signal flow: Critical for Bottle Filling when handling intermediate to advanced control logic

  • Good for modular programming: Critical for Bottle Filling when handling intermediate to advanced control logic

  • Reusable components: Critical for Bottle Filling when handling intermediate to advanced control logic

  • Excellent for process control: Critical for Bottle Filling when handling intermediate to advanced control logic

  • Good for continuous operations: Critical for Bottle Filling when handling intermediate to advanced control logic


Why Function Blocks Fits Bottle Filling:

Bottle Filling systems in Packaging typically involve:

  • Sensors: Bottle presence sensors (fiber optic or inductive) for container detection, Level sensors (capacitive, ultrasonic, or optical) for fill detection, Load cells for gravimetric (weight-based) filling

  • Actuators: Servo-driven filling valves for precise flow control, Pneumatic pinch valves for on/off flow control, Bottle handling star wheels and timing screws

  • Complexity: Intermediate to Advanced with challenges including Preventing dripping and stringing after fill cutoff


Programming Fundamentals in Function Blocks:

StandardBlocks:
- logic: AND, OR, XOR, NOT - Boolean logic operations
- comparison: EQ, NE, LT, GT, LE, GE - Compare values
- math: ADD, SUB, MUL, DIV, MOD - Arithmetic operations

TimersCounters:
- ton: Timer On-Delay - Output turns ON after preset time
- tof: Timer Off-Delay - Output turns OFF after preset time
- tp: Pulse Timer - Output pulses for preset time

Connections:
- wires: Connect output pins to input pins to pass data
- branches: One output can connect to multiple inputs
- feedback: Outputs can feed back to inputs for state machines

Best Practices for Function Blocks:

  • Arrange blocks for clear left-to-right data flow

  • Use consistent spacing and alignment for readability

  • Label all inputs and outputs with meaningful names

  • Create custom FBs for frequently repeated logic patterns

  • Minimize wire crossings by careful block placement


Common Mistakes to Avoid:

  • Creating feedback loops without proper initialization

  • Connecting incompatible data types

  • Not considering execution order dependencies

  • Overcrowding networks making them hard to read


Typical Applications:

1. HVAC control: Directly applicable to Bottle Filling
2. Temperature control: Related control patterns
3. Flow control: Related control patterns
4. Batch processing: Related control patterns

Understanding these fundamentals prepares you to implement effective Function Blocks solutions for Bottle Filling using Unitronics VisiLogic / UniLogic.

Implementing Bottle Filling with Function Blocks

Bottle filling control systems manage the precise dispensing of liquids into containers at high speeds while maintaining accuracy and preventing spillage. PLCs coordinate container handling, fill control, capping, and quality inspection in an integrated packaging line.

This walkthrough demonstrates practical implementation using Unitronics VisiLogic / UniLogic and Function Blocks programming.

System Requirements:

A typical Bottle Filling implementation includes:

Input Devices (Sensors):
1. Bottle presence sensors (fiber optic or inductive) for container detection: Critical for monitoring system state
2. Level sensors (capacitive, ultrasonic, or optical) for fill detection: Critical for monitoring system state
3. Load cells for gravimetric (weight-based) filling: Critical for monitoring system state
4. Flow meters (magnetic or mass flow) for volumetric filling: Critical for monitoring system state
5. Encoder feedback for rotary filler position: Critical for monitoring system state

Output Devices (Actuators):
1. Servo-driven filling valves for precise flow control: Primary control output
2. Pneumatic pinch valves for on/off flow control: Supporting control function
3. Bottle handling star wheels and timing screws: Supporting control function
4. Capping chuck drives (servo or pneumatic): Supporting control function
5. Torque limiters for cap tightening: Supporting control function

Control Equipment:

  • Filling nozzles (gravity, pressure, vacuum)

  • Product tanks with level control

  • CIP (clean-in-place) systems

  • Cap feeding and sorting equipment


Control Strategies for Bottle Filling:

1. Primary Control: Automated bottle filling and capping systems using PLCs for precise volume control, speed optimization, and quality assurance.
2. Safety Interlocks: Preventing Precise fill volume
3. Error Recovery: Handling High-speed operation

Implementation Steps:

Step 1: Characterize product flow properties (viscosity, foaming, temperature sensitivity)

In VisiLogic / UniLogic, characterize product flow properties (viscosity, foaming, temperature sensitivity).

Step 2: Determine fill method based on accuracy requirements and product type

In VisiLogic / UniLogic, determine fill method based on accuracy requirements and product type.

Step 3: Design container handling for smooth, jam-free operation

In VisiLogic / UniLogic, design container handling for smooth, jam-free operation.

Step 4: Implement fill sequence with proper valve timing and deceleration

In VisiLogic / UniLogic, implement fill sequence with proper valve timing and deceleration.

Step 5: Add bulk/dribble transition logic for gravimetric filling

In VisiLogic / UniLogic, add bulk/dribble transition logic for gravimetric filling.

Step 6: Program calibration routines for automatic fill adjustment

In VisiLogic / UniLogic, program calibration routines for automatic fill adjustment.


Unitronics Function Design:

Function block design in Unitronics uses user-defined FBs in UniLogic (more limited in VisiLogic). Extensive vendor-provided helper FBs cover common tasks (PID, motion, communication, HMI utilities). OEM machine builders typically maintain private FB libraries for their common machine patterns, though code reuse is less mature than in mainstream PLC ecosystems.

Common Challenges and Solutions:

1. Preventing dripping and stringing after fill cutoff

  • Solution: Function Blocks addresses this through Visual representation of signal flow.


2. Handling foaming products that give false level readings

  • Solution: Function Blocks addresses this through Good for modular programming.


3. Maintaining accuracy at high speeds

  • Solution: Function Blocks addresses this through Reusable components.


4. Synchronizing multi-head rotary fillers

  • Solution: Function Blocks addresses this through Excellent for process control.


Safety Considerations:

  • Guarding around rotating components

  • Interlocked access doors with safe stop

  • Bottle breakage detection and containment

  • Overpressure protection for pressure filling

  • Chemical handling safety for cleaning solutions


Performance Metrics:

  • Task and I/O timing: Record minimum, average, and maximum values under a defined test load

  • Accuracy: Define an acceptable tolerance and compare it with calibrated reference measurements

  • Throughput: Count completed cycles over a fixed interval and record rejected or incomplete cycles

  • Fault response: Measure detection, safe-state, alarm, and recovery behavior for each test case

  • Resource use: Record memory, communications load, and diagnostic-buffer behavior

Unitronics Diagnostic Tools:

UniLogic (current) and VisiLogic (legacy) integrated debuggers with breakpoints,Built-in simulator covering PLC logic, HMI screens, alarms, recipes, and data tables,Web visualisation for UniStream — remote HMI viewing without additional software,SD card logging with PC-side export tools for offline trend analysis,Modbus RTU/TCP transaction logging built into the IDE,Controller status monitor — CPU load, scan time, memory usage,HMI event logger capturing operator actions for audit purposes,CAN bus diagnostic tools for CANopen-equipped models,Remote support tool — Unitronics' own screen-sharing for technical support,User community forum with active troubleshooting discussions

Use the monitoring and diagnostic functions available in your VisiLogic / UniLogic version, and record the software, firmware, hardware, workload, and test procedure with every result.

Unitronics Function Blocks Example for Bottle Filling

Illustrative Function Blocks example for Bottle Filling using Unitronics terminology. Adapt the syntax to your VisiLogic / UniLogic release, compile it, and verify it in an isolated test environment before use on equipment.

(* Unitronics VisiLogic / UniLogic - Bottle Filling Control *)
(* Reusable Function Blocks Implementation *)
(* Function block design in Unitronics uses user-defined FBs in *)

FUNCTION_BLOCK FB_BOTTLE_FILLING_Controller

VAR_INPUT
    bEnable : BOOL;                  (* Enable control *)
    bReset : BOOL;                   (* Fault reset *)
    rProcessValue : REAL;            (* Bottle presence sensors (fiber optic or inductive) for container detection *)
    rSetpoint : REAL := 100.0;  (* Illustrative value; replace with a reviewed requirement *)
    bEmergencyStop : BOOL;           (* Safety input *)
END_VAR

VAR_OUTPUT
    rControlOutput : REAL;           (* Servo-driven filling valves for precise flow control *)
    bRunning : BOOL;                 (* Process active *)
    bComplete : BOOL;                (* Cycle complete *)
    bFault : BOOL;                   (* Fault status *)
    nFaultCode : INT;                (* Diagnostic code *)
END_VAR

VAR
    (* Internal Function Blocks *)
    fbSafety : FB_SafetyMonitor;     (* Safety logic *)
    fbRamp : FB_RampGenerator;       (* Soft start/stop *)
    fbPID : FB_PIDController;        (* Process control *)
    fbDiag : FB_Diagnostics;         (* Alarm handling uses UniLogic's built-in Alarm Manager — configure alarm conditions in tables with severity, message text, and logging behaviour, and the engine handles detection, acknowledgement, history, and HMI display without custom code. VisiLogic uses a simpler alarm approach via HMI event handlers. *)

    (* Internal State *)
    eInternalState : E_ControlState;
    tonWatchdog : TON;
END_VAR

(* Safety Monitor - Guarding around rotating components *)
fbSafety(
    Enable := bEnable,
    EmergencyStop := bEmergencyStop,
    ProcessValue := rProcessValue,
    HighLimit := rSetpoint * 1.2,
    LowLimit := rSetpoint * 0.1
);

(* Main Control Logic *)
IF fbSafety.SafeToRun THEN
    (* Ramp Generator - Prevents startup surge *)
    fbRamp(
        Enable := bEnable,
        TargetValue := rSetpoint,
        RampRate := 20.0,  (* Illustrative value; tune and verify for the process *)
        CurrentValue => rSetpoint
    );

    (* PID Controller - Process regulation *)
    fbPID(
        Enable := fbRamp.InPosition,
        ProcessValue := rProcessValue,
        Setpoint := fbRamp.CurrentValue,
        Kp := 1.0,
        Ki := 0.1,
        Kd := 0.05,
        OutputMin := 0.0,
        OutputMax := 100.0
    );

    rControlOutput := fbPID.Output;
    bRunning := TRUE;
    bFault := FALSE;
    nFaultCode := 0;

ELSE
    (* Safe State - Interlocked access doors with safe stop *)
    rControlOutput := 0.0;
    bRunning := FALSE;
    bFault := NOT bEnable;  (* Only fault if not intentional stop *)
    nFaultCode := fbSafety.FaultCode;
END_IF;

(* Diagnostics - Data logging uses UniLogic's Data Samplers — configured triggers (time-based or event-based) write structured records to Data Tables or SD card in CSV format. Exported files can be pushed via FTP or email. For cloud integration, UniCloud provides managed data ingestion. Simpler VisiLogic projects use HMI-triggered SD writes via custom ladder code. *)
fbDiag(
    ProcessRunning := bRunning,
    FaultActive := bFault,
    ProcessValue := rProcessValue,
    ControlOutput := rControlOutput
);

(* Watchdog - Detects frozen control *)
tonWatchdog(IN := bRunning AND NOT fbPID.OutputChanging, PT := T#10S);
IF tonWatchdog.Q THEN
    bFault := TRUE;
    nFaultCode := 99;  (* Watchdog fault *)
END_IF;

(* Reset Logic *)
IF bReset AND NOT bEmergencyStop THEN
    bFault := FALSE;
    nFaultCode := 0;
    fbDiag.ClearAlarms();
END_IF;

END_FUNCTION_BLOCK

Code Explanation:

  • 1.Encapsulated function block follows Function block design in Unitronics uses - reusable across Packaging projects
  • 2.FB_SafetyMonitor illustrates status checks and high/low limits; it is not a certified safety function
  • 3.FB_RampGenerator prevents startup issues common in Bottle Filling systems
  • 4.FB_PIDController tuned for Packaging: Kp=1.0, Ki=0.1
  • 5.Watchdog timer illustrates one way to flag an unchanged output for diagnosis
  • 6.Diagnostic function block enables Data logging uses UniLogic's Data Samplers — configured triggers (time-based or event-based) write structured records to Data Tables or SD card in CSV format. Exported files can be pushed via FTP or email. For cloud integration, UniCloud provides managed data ingestion. Simpler VisiLogic projects use HMI-triggered SD writes via custom ladder code. and Alarm handling uses UniLogic's built-in Alarm Manager — configure alarm conditions in tables with severity, message text, and logging behaviour, and the engine handles detection, acknowledgement, history, and HMI display without custom code. VisiLogic uses a simpler alarm approach via HMI event handlers.

Best Practices

  • Follow Unitronics naming conventions: Unitronics projects use IDE-managed tag names rather than raw memory addressing.
  • Unitronics function design: Function block design in Unitronics uses user-defined FBs in UniLogic (more limi
  • Data organization: Unitronics uses its own tag database concept rather than IEC-standard data block
  • Function Blocks: Arrange blocks for clear left-to-right data flow
  • Function Blocks: Use consistent spacing and alignment for readability
  • Function Blocks: Label all inputs and outputs with meaningful names
  • Bottle Filling: Use minimum 10 readings for statistical fill tracking
  • Bottle Filling: Implement automatic re-zero of scales at regular intervals
  • Bottle Filling: Provide separate parameters for each product recipe
  • Debug with VisiLogic / UniLogic: Use the built-in simulator to reproduce issues before hardware visit
  • Safety: Guarding around rotating components
  • Use a compatible simulator or isolated test rig to test Bottle Filling logic before deployment

Common Pitfalls to Avoid

  • Function Blocks: Creating feedback loops without proper initialization
  • Function Blocks: Connecting incompatible data types
  • Function Blocks: Not considering execution order dependencies
  • Unitronics common error: VisiLogic-to-UniLogic migration issues — not all projects convert cleanly
  • Bottle Filling: Preventing dripping and stringing after fill cutoff
  • Bottle Filling: Handling foaming products that give false level readings
  • Neglecting to validate Bottle presence sensors (fiber optic or inductive) for container detection leads to control errors
  • Insufficient comments make Function Blocks programs unmaintainable over time

Related Certifications

🏆Unitronics Certified Integrator
🏆UniLogic Developer Training
🏆Advanced Unitronics Programming Certification

Applying Function Blocks to Bottle Filling using Unitronics VisiLogic / UniLogic requires understanding the platform, the process, and the project's acceptance criteria. This guide has covered implementation structure, an illustrative code example, verification practices, and common pitfalls for a intermediate to advanced Bottle Filling exercise.

Use the practices outlined here to create a design that can be reviewed and tested. Define performance targets in the project requirements and confirm them with repeatable measurements.

Next Steps:

1. Check Sources: Read the current VisiLogic / UniLogic help, controller manual, release notes, and relevant standards
2. Practice Safely: Adapt the example in a simulator or isolated training setup
3. Review: Have the I/O map, state behavior, faults, and recovery steps reviewed
4. Test: Record normal, boundary, fault, restart, and communications test results

Function Blocks Foundation:

Function Block Diagram (FBD) is a graphical programming language where functions and function blocks are represented as boxes connected by signal line...

Project duration depends on scope, reviews, hardware availability, software and firmware versions, testing, commissioning, and site constraints. Remember: Use minimum 10 readings for statistical fill tracking

For further learning, explore related topics including Temperature control, Pharmaceutical liquid filling, and Unitronics platform-specific features for Bottle Filling optimization.