Learn PLCs free
Intermediate15 min readWater & Wastewater

Kinco Sequential Function Charts (SFC) for Pump Control

Learn Sequential Function Charts (SFC) programming for Pump Control using Kinco Kincobuilder. Includes code examples, best practices, and step-by-step implementation guide for Water & Wastewater applications.

💻
Platform
Kincobuilder
📊
Complexity
Intermediate
⏱️
Project Duration
2-4 weeks

Implementing Sequential Function Charts (SFC) for Pump Control using Kinco Kincobuilder requires a documented design, applicable standards, and project-specific acceptance criteria. This guide organizes practical checks for code structure, diagnostics, testing, and maintenance.

The example references K3-family terminology, but model capabilities vary. Verify the controller manual, the installed Kincobuilder version, and any applicable machinery, process, electrical, or functional-safety requirements for the actual project.

Best practices for Pump Control encompass multiple dimensions: proper handling of 5 sensor types, safe control of 5 different actuators, managing pressure regulation, and ensuring compliance with relevant industry standards. The Sequential Function Charts (SFC) approach, when properly implemented, provides perfect for sequential processes and clear visualization of process flow, both critical for intermediate projects.

This guide presents a reviewable approach to Kinco Sequential Function Charts (SFC) programming for Pump Control, covering code organization, documentation, test procedures, and maintenance handoff. The sample logic is educational and must be compiled, simulated, peer-reviewed, and tested against the project's acceptance criteria before use on equipment.

Kinco Kincobuilder for Pump Control

Kincobuilder is a programming environment associated with Kinco controller families such as K3, K5, K6. This guide uses Sequential Function Charts (SFC) terminology from the supplied guide dataset, but controller capabilities and language support can change by model, firmware, software edition, and license.

Verify Before You Start:

  • The selected controller supports the required Sequential Function Charts (SFC) constructs

  • The project version matches the installed Kincobuilder release

  • Required communications, motion, safety, and simulation options are licensed

  • Firmware and device-description files are compatible with the project

  • The vendor manuals used for the design match the exact hardware revision


Application Planning:

For a Pump Control exercise, map the required inputs and outputs before writing logic. The example considers 5 sensor types, including Pressure transmitters, Flow meters, Level sensors, and 5 actuator types.

Control Equipment for Pump Control:

  • Centrifugal pumps for high flow applications

  • Positive displacement pumps for metering

  • Submersible pumps for wet well applications

  • Booster pump systems for pressure maintenance


Controller-family references used in this guide include:

  • K3: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide

  • K5: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide

  • K6: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide

  • K7: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide


Hardware Selection Checklist:

  • Count local and remote I/O, including planned expansion

  • Measure the required task and communications update rates

  • Identify memory, data-retention, diagnostics, and cybersecurity requirements

  • Treat safety functions as a separate, standards-led design activity

  • Confirm lifecycle status, regional availability, licensing, and support


Source and Validation Note:

This page does not represent a vendor certification or a hardware acceptance test. Use current Kinco manuals, release notes, and safety documentation as the authority for product-specific behavior. Validate adapted logic in a simulator or isolated test setup before connecting it to equipment.

Investment Considerations:

For Pump Control projects, compare hardware, software licensing, training, engineering, test equipment, commissioning, spares, and ongoing support. Obtain current pricing and lifecycle information directly from the vendor or an authorized regional supplier.

Understanding Sequential Function Charts (SFC) for Pump Control

Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by transitions, ideal for batch processes and machine sequences.

Execution Model:

Only active steps execute their actions. Transitions define conditions for moving between steps. Multiple steps can be active simultaneously in parallel branches.

Core Advantages for Pump Control:

  • Perfect for sequential processes: Critical for Pump Control when handling intermediate control logic

  • Clear visualization of process flow: Critical for Pump Control when handling intermediate control logic

  • Easy to understand process steps: Critical for Pump Control when handling intermediate control logic

  • Good for batch operations: Critical for Pump Control when handling intermediate control logic

  • Simplifies complex sequences: Critical for Pump Control when handling intermediate control logic


Why Sequential Function Charts (SFC) Fits Pump Control:

Pump Control systems in Water & Wastewater typically involve:

  • Sensors: Pressure transmitters for discharge and suction pressure, Flow meters (magnetic, ultrasonic, or vortex), Level transmitters for tank or wet well level

  • Actuators: Variable frequency drives (VFDs) for speed control, Motor starters (DOL or soft start), Control valves for flow regulation

  • Complexity: Intermediate with challenges including Preventing cavitation at low suction pressure


Control Strategies for Pump Control:

  • constant: Maintain fixed speed or output

  • pressure: PID control to maintain discharge pressure setpoint

  • flow: PID control to maintain flow rate setpoint


Programming Fundamentals in Sequential Function Charts (SFC):

Steps:
- initialStep: Double-bordered box - starting point of sequence, active on program start
- normalStep: Single-bordered box - becomes active when preceding transition fires
- actions: Associated code that executes while step is active

Transitions:
- condition: Boolean expression that must be TRUE to advance
- firing: Transition fires when preceding step is active AND condition is TRUE
- priority: In selective branches, transitions are evaluated in defined order

ActionQualifiers:
- N: Non-stored - executes while step is active
- S: Set - sets output TRUE on step entry, remains TRUE
- R: Reset - sets output FALSE on step entry

Best Practices for Sequential Function Charts (SFC):

  • Start with a clear process flow diagram before implementing SFC

  • Use descriptive step names indicating what happens (e.g., Filling, Heating)

  • Keep transition conditions simple - complex logic goes in action code

  • Implement timeout transitions to prevent stuck sequences

  • Always provide a path back to initial step for reset/restart


Common Mistakes to Avoid:

  • Forgetting to include stop/abort transitions for emergency handling

  • Creating deadlocks where no transition can fire

  • Not handling the case where transition conditions never become TRUE

  • Using S (Set) actions without corresponding R (Reset) actions


Typical Applications:

1. Bottle filling: Directly applicable to Pump Control
2. Assembly sequences: Related control patterns
3. Material handling: Related control patterns
4. Batch mixing: Related control patterns

Understanding these fundamentals prepares you to implement effective Sequential Function Charts (SFC) solutions for Pump Control using Kinco Kincobuilder.

Implementing Pump Control with Sequential Function Charts (SFC)

Pump control systems use PLCs to regulate liquid flow in industrial processes, water treatment, and building services. These systems manage pump operation, protect equipment, optimize energy use, and maintain process parameters.

This walkthrough demonstrates practical implementation using Kinco Kincobuilder and Sequential Function Charts (SFC) programming.

System Requirements:

A typical Pump Control implementation includes:

Input Devices (Sensors):
1. Pressure transmitters for discharge and suction pressure: Critical for monitoring system state
2. Flow meters (magnetic, ultrasonic, or vortex): Critical for monitoring system state
3. Level transmitters for tank or wet well level: Critical for monitoring system state
4. Temperature sensors for bearing and motor monitoring: Critical for monitoring system state
5. Vibration sensors for predictive maintenance: Critical for monitoring system state

Output Devices (Actuators):
1. Variable frequency drives (VFDs) for speed control: Primary control output
2. Motor starters (DOL or soft start): Supporting control function
3. Control valves for flow regulation: Supporting control function
4. Isolation valves (actuated for remote operation): Supporting control function
5. Check valves to prevent backflow: Supporting control function

Control Equipment:

  • Centrifugal pumps for high flow applications

  • Positive displacement pumps for metering

  • Submersible pumps for wet well applications

  • Booster pump systems for pressure maintenance


Control Strategies for Pump Control:

  • constant: Maintain fixed speed or output

  • pressure: PID control to maintain discharge pressure setpoint

  • flow: PID control to maintain flow rate setpoint

  • level: Control tank/wet well level within band


Implementation Steps:

Step 1: Characterize pump curve and system curve

In Kincobuilder, characterize pump curve and system curve.

Step 2: Size VFD for application (constant torque vs. variable torque)

In Kincobuilder, size vfd for application (constant torque vs. variable torque).

Step 3: Implement primary control loop (pressure, flow, or level)

In Kincobuilder, implement primary control loop (pressure, flow, or level).

Step 4: Add pump protection logic (minimum flow, temperature, seal)

In Kincobuilder, add pump protection logic (minimum flow, temperature, seal).

Step 5: Program lead/lag sequencing with alternation

In Kincobuilder, program lead/lag sequencing with alternation.

Step 6: Implement soft start/stop ramps for smooth operation

In Kincobuilder, implement soft start/stop ramps for smooth operation.


Kinco Function Design:

Subroutines as the primary reuse mechanism; some manufacturer-supplied motion FBs available.

Common Challenges and Solutions:

1. Preventing cavitation at low suction pressure

  • Solution: Sequential Function Charts (SFC) addresses this through Perfect for sequential processes.


2. Managing minimum flow requirements

  • Solution: Sequential Function Charts (SFC) addresses this through Clear visualization of process flow.


3. Coordinating VFD speed with system pressure

  • Solution: Sequential Function Charts (SFC) addresses this through Easy to understand process steps.


4. Handling pump cycling with varying demand

  • Solution: Sequential Function Charts (SFC) addresses this through Good for batch operations.


Safety Considerations:

  • Dry run protection using flow or level monitoring

  • Overtemperature protection for motor and bearings

  • Overload protection through current monitoring

  • Vibration trips for mechanical failure detection

  • Emergency stop with proper system depressurization


Performance Metrics:

  • Task and I/O timing: Record minimum, average, and maximum values under a defined test load

  • Accuracy: Define an acceptable tolerance and compare it with calibrated reference measurements

  • Throughput: Count completed cycles over a fixed interval and record rejected or incomplete cycles

  • Fault response: Measure detection, safe-state, alarm, and recovery behavior for each test case

  • Resource use: Record memory, communications load, and diagnostic-buffer behavior

Kinco Diagnostic Tools:

Kincobuilder online monitor,Soft-element watch table,Built-in offline simulator,Motion-axis live monitor view,Modbus / CANopen communication analyzer,Kinco MK HMI integrated diagnostics,Distributor support engineers,Kinco user community forums

Use the monitoring and diagnostic functions available in your Kincobuilder version, and record the software, firmware, hardware, workload, and test procedure with every result.

Kinco Sequential Function Charts (SFC) Example for Pump Control

Illustrative Sequential Function Charts (SFC) example for Pump Control using Kinco terminology. Adapt the syntax to your Kincobuilder release, compile it, and verify it in an isolated test environment before use on equipment.

// Kinco Kincobuilder - Pump Control Control
// Sequential Function Charts (SFC) Implementation for Water & Wastewater
// Raw-address conventions (X / Y / M / VW) with rung-level com

// ============================================
// Variable Declarations
// ============================================
VAR
    bEnable : BOOL := FALSE;
    bEmergencyStop : BOOL := FALSE;
    rPressuretransmitters : REAL;
    rCentrifugalpumps : REAL;
END_VAR

// ============================================
// Input Conditioning - Pressure transmitters for discharge and suction pressure
// ============================================
// Standard input processing
IF rPressuretransmitters > 0.0 THEN
    bEnable := TRUE;
END_IF;

// ============================================
// Safety Interlock - Dry run protection using flow or level monitoring
// ============================================
IF bEmergencyStop THEN
    rCentrifugalpumps := 0.0;
    bEnable := FALSE;
END_IF;

// ============================================
// Main Pump Control Control Logic
// ============================================
IF bEnable AND NOT bEmergencyStop THEN
    // Pump control systems use PLCs to regulate liquid flow in ind
    rCentrifugalpumps := rPressuretransmitters * 1.0; (* Illustrative scaling only *)

    // Process monitoring
    // Add specific control logic here
ELSE
    rCentrifugalpumps := 0.0;
END_IF;

Code Explanation:

  • 1.Sequential Function Charts (SFC) structure organized for a Pump Control training example
  • 2.Input conditioning handles Pressure transmitters for discharge and suction pressure signals
  • 3.Safety interlock ensures Dry run protection using flow or level monitoring always takes priority
  • 4.Main control implements Pump control systems use PLCs to regulat
  • 5.Adapt the scan-cycle assumptions to the selected K3 task configuration and verify them by measurement

Best Practices

  • Follow Kinco naming conventions: Raw-address conventions (X / Y / M / VW) with rung-level comments; symbolic nami
  • Kinco function design: Subroutines as the primary reuse mechanism; some manufacturer-supplied motion FB
  • Data organization: No structured DB; VW (word-addressed) memory bank holds persistent data with eng
  • Sequential Function Charts (SFC): Start with a clear process flow diagram before implementing SFC
  • Sequential Function Charts (SFC): Use descriptive step names indicating what happens (e.g., Filling, Heating)
  • Sequential Function Charts (SFC): Keep transition conditions simple - complex logic goes in action code
  • Pump Control: Use PID with derivative on PV for pressure control
  • Pump Control: Implement soft start ramps even with VFD (200-500ms)
  • Pump Control: Add flow proving before considering pump operational
  • Debug with Kincobuilder: Use the offline simulator before live download
  • Safety: Dry run protection using flow or level monitoring
  • Use a compatible simulator or isolated test rig to test Pump Control logic before deployment

Common Pitfalls to Avoid

  • Sequential Function Charts (SFC): Forgetting to include stop/abort transitions for emergency handling
  • Sequential Function Charts (SFC): Creating deadlocks where no transition can fire
  • Sequential Function Charts (SFC): Not handling the case where transition conditions never become TRUE
  • Kinco common error: Pulse-output frequency exceeding rated CPU spec
  • Pump Control: Preventing cavitation at low suction pressure
  • Pump Control: Managing minimum flow requirements
  • Neglecting to validate Pressure transmitters for discharge and suction pressure leads to control errors
  • Insufficient comments make Sequential Function Charts (SFC) programs unmaintainable over time

Related Certifications

🏆Kinco distributor-led engineer training
🏆Motion-control specialist certificates

Applying Sequential Function Charts (SFC) to Pump Control using Kinco Kincobuilder requires understanding the platform, the process, and the project's acceptance criteria. This guide has covered implementation structure, an illustrative code example, verification practices, and common pitfalls for a intermediate Pump Control exercise.

Use the practices outlined here to create a design that can be reviewed and tested. Define performance targets in the project requirements and confirm them with repeatable measurements.

Next Steps:

1. Check Sources: Read the current Kincobuilder help, controller manual, release notes, and relevant standards
2. Practice Safely: Adapt the example in a simulator or isolated training setup
3. Review: Have the I/O map, state behavior, faults, and recovery steps reviewed
4. Test: Record normal, boundary, fault, restart, and communications test results

Sequential Function Charts (SFC) Foundation:

Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by tran...

Project duration depends on scope, reviews, hardware availability, software and firmware versions, testing, commissioning, and site constraints. Remember: Use PID with derivative on PV for pressure control

For further learning, explore related topics including Assembly sequences, Wastewater treatment, and Kinco platform-specific features for Pump Control optimization.