Learn PLCs free
Intermediate20 min readPackaging

Emerson Function Blocks for Packaging Automation

Learn Function Blocks programming for Packaging Automation using Emerson PAC Machine Edition / Movicon NExT / DeltaV Studio. Includes code examples, best practices, and step-by-step implementation guide for Packaging applications.

💻
Platform
PAC Machine Edition / Movicon NExT / DeltaV Studio
📊
Complexity
Intermediate to Advanced
⏱️
Project Duration
3-6 weeks

Optimizing Function Blocks for Packaging Automation applications in Emerson's PAC Machine Edition / Movicon NExT / DeltaV Studio requires measuring the baseline and understanding the demands of Packaging. This guide focuses on techniques you can evaluate with task timing, scan-time traces, memory use, and controlled fault tests.

For intermediate to advanced applications like Packaging Automation, check which diagnostics and profiling tools are available in your installed PAC Machine Edition / Movicon NExT / DeltaV Studio version. Controller model, firmware, task configuration, communications, and I/O update behavior can all affect the result.

Performance considerations for Packaging Automation systems extend beyond basic functionality. Critical factors include 5 sensor types, 5 actuators, communications load, and the need to handle product changeover. Evaluate whether visual representation of signal flow helps the design, then measure the actual task and I/O timing on the selected configuration.

This guide covers memory management, execution order, Function Blocks-specific tuning, and a repeatable measurement plan for Packaging Automation applications. Treat every optimization as a hypothesis: record the baseline, change one variable, retest the same workload, and keep the change only when the measured result and code maintainability both improve.

Emerson PAC Machine Edition / Movicon NExT / DeltaV Studio for Packaging Automation

PAC Machine Edition / Movicon NExT / DeltaV Studio is a programming environment associated with Emerson controller families such as PACSystems RX3i, PACSystems RX7i, PACSystems RSTi-EP. This guide uses Function Blocks terminology from the supplied guide dataset, but controller capabilities and language support can change by model, firmware, software edition, and license.

Verify Before You Start:

  • The selected controller supports the required Function Blocks constructs

  • The project version matches the installed PAC Machine Edition / Movicon NExT / DeltaV Studio release

  • Required communications, motion, safety, and simulation options are licensed

  • Firmware and device-description files are compatible with the project

  • The vendor manuals used for the design match the exact hardware revision


Application Planning:

For a Packaging Automation exercise, map the required inputs and outputs before writing logic. The example considers 5 sensor types, including Vision systems, Weight sensors, Barcode scanners, and 5 actuator types.

Control Equipment for Packaging Automation:

  • Form-fill-seal machines (horizontal and vertical)

  • Case erectors and sealers

  • Labeling systems (pressure sensitive, shrink sleeve)

  • Case packers (drop, wrap-around, robotic)


Controller-family references used in this guide include:

  • PACSystems RX3i: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide

  • PACSystems RX7i: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide

  • PACSystems RSTi-EP: Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide

  • VersaMax (legacy): Confirm CPU, I/O, memory, communications, and Function Blocks support in the current selection guide


Hardware Selection Checklist:

  • Count local and remote I/O, including planned expansion

  • Measure the required task and communications update rates

  • Identify memory, data-retention, diagnostics, and cybersecurity requirements

  • Treat safety functions as a separate, standards-led design activity

  • Confirm lifecycle status, regional availability, licensing, and support


Source and Validation Note:

This page does not represent a vendor certification or a hardware acceptance test. Use current Emerson manuals, release notes, and safety documentation as the authority for product-specific behavior. Validate adapted logic in a simulator or isolated test setup before connecting it to equipment.

Investment Considerations:

For Packaging Automation projects, compare hardware, software licensing, training, engineering, test equipment, commissioning, spares, and ongoing support. Obtain current pricing and lifecycle information directly from the vendor or an authorized regional supplier.

Understanding Function Blocks for Packaging Automation

Function Block Diagram (FBD) is a graphical programming language where functions and function blocks are represented as boxes connected by signal lines. Data flows from left to right through the network.

Execution Model:

Blocks execute based on data dependencies - a block executes only when all its inputs are available. Networks execute top to bottom when dependencies allow.

Core Advantages for Packaging Automation:

  • Visual representation of signal flow: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Good for modular programming: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Reusable components: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Excellent for process control: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Good for continuous operations: Critical for Packaging Automation when handling intermediate to advanced control logic


Why Function Blocks Fits Packaging Automation:

Packaging Automation systems in Packaging typically involve:

  • Sensors: Product detection sensors for counting and positioning, Registration sensors for label and film alignment, Barcode/2D code readers for verification

  • Actuators: Servo drives for precise motion control, Pneumatic cylinders for pick-and-place, Vacuum generators and cups

  • Complexity: Intermediate to Advanced with challenges including Maintaining registration at high speeds


Programming Fundamentals in Function Blocks:

StandardBlocks:
- logic: AND, OR, XOR, NOT - Boolean logic operations
- comparison: EQ, NE, LT, GT, LE, GE - Compare values
- math: ADD, SUB, MUL, DIV, MOD - Arithmetic operations

TimersCounters:
- ton: Timer On-Delay - Output turns ON after preset time
- tof: Timer Off-Delay - Output turns OFF after preset time
- tp: Pulse Timer - Output pulses for preset time

Connections:
- wires: Connect output pins to input pins to pass data
- branches: One output can connect to multiple inputs
- feedback: Outputs can feed back to inputs for state machines

Best Practices for Function Blocks:

  • Arrange blocks for clear left-to-right data flow

  • Use consistent spacing and alignment for readability

  • Label all inputs and outputs with meaningful names

  • Create custom FBs for frequently repeated logic patterns

  • Minimize wire crossings by careful block placement


Common Mistakes to Avoid:

  • Creating feedback loops without proper initialization

  • Connecting incompatible data types

  • Not considering execution order dependencies

  • Overcrowding networks making them hard to read


Typical Applications:

1. HVAC control: Directly applicable to Packaging Automation
2. Temperature control: Related control patterns
3. Flow control: Related control patterns
4. Batch processing: Related control patterns

Understanding these fundamentals prepares you to implement effective Function Blocks solutions for Packaging Automation using Emerson PAC Machine Edition / Movicon NExT / DeltaV Studio.

Implementing Packaging Automation with Function Blocks

Packaging automation systems use PLCs to coordinate primary, secondary, and tertiary packaging operations. These systems control filling, labeling, case packing, palletizing, and integration with production and warehouse systems.

This walkthrough demonstrates practical implementation using Emerson PAC Machine Edition / Movicon NExT / DeltaV Studio and Function Blocks programming.

System Requirements:

A typical Packaging Automation implementation includes:

Input Devices (Sensors):
1. Product detection sensors for counting and positioning: Critical for monitoring system state
2. Registration sensors for label and film alignment: Critical for monitoring system state
3. Barcode/2D code readers for verification: Critical for monitoring system state
4. Vision systems for quality inspection: Critical for monitoring system state
5. Reject confirmation sensors: Critical for monitoring system state

Output Devices (Actuators):
1. Servo drives for precise motion control: Primary control output
2. Pneumatic cylinders for pick-and-place: Supporting control function
3. Vacuum generators and cups: Supporting control function
4. Glue and tape applicators: Supporting control function
5. Film tensioners and seal bars: Supporting control function

Control Equipment:

  • Form-fill-seal machines (horizontal and vertical)

  • Case erectors and sealers

  • Labeling systems (pressure sensitive, shrink sleeve)

  • Case packers (drop, wrap-around, robotic)


Control Strategies for Packaging Automation:

1. Primary Control: Automated packaging systems using PLCs for product wrapping, boxing, labeling, and palletizing.
2. Safety Interlocks: Preventing Product changeover
3. Error Recovery: Handling High-speed synchronization

Implementation Steps:

Step 1: Define packaging specifications for all product variants

In PAC Machine Edition / Movicon NExT / DeltaV Studio, define packaging specifications for all product variants.

Step 2: Create motion profiles for each packaging format

In PAC Machine Edition / Movicon NExT / DeltaV Studio, create motion profiles for each packaging format.

Step 3: Implement registration control with encoder feedback

In PAC Machine Edition / Movicon NExT / DeltaV Studio, implement registration control with encoder feedback.

Step 4: Program pattern generation for case and pallet loading

In PAC Machine Edition / Movicon NExT / DeltaV Studio, program pattern generation for case and pallet loading.

Step 5: Add reject handling with confirmation logic

In PAC Machine Edition / Movicon NExT / DeltaV Studio, add reject handling with confirmation logic.

Step 6: Implement barcode/vision integration for verification

In PAC Machine Edition / Movicon NExT / DeltaV Studio, implement barcode/vision integration for verification.


Emerson Function Design:

PME FB libraries cover motion, drives, communications, safety. DeltaV control-module library is the central engineering artefact. EPC partners maintain extensive private libraries on both platforms.

Common Challenges and Solutions:

1. Maintaining registration at high speeds

  • Solution: Function Blocks addresses this through Visual representation of signal flow.


2. Handling product variability in automated systems

  • Solution: Function Blocks addresses this through Good for modular programming.


3. Quick changeover between package formats

  • Solution: Function Blocks addresses this through Reusable components.


4. Synchronizing multiple machines in a line

  • Solution: Function Blocks addresses this through Excellent for process control.


Safety Considerations:

  • Guarding around rotating and reciprocating parts

  • Safety-rated position monitoring for setup access

  • Heat hazard protection for seal bars and shrink tunnels

  • Proper pinch point guarding

  • Robot safety zones and light curtains


Performance Metrics:

  • Task and I/O timing: Record minimum, average, and maximum values under a defined test load

  • Accuracy: Define an acceptable tolerance and compare it with calibrated reference measurements

  • Throughput: Count completed cycles over a fixed interval and record rejected or incomplete cycles

  • Fault response: Measure detection, safe-state, alarm, and recovery behavior for each test case

  • Resource use: Record memory, communications load, and diagnostic-buffer behavior

Emerson Diagnostic Tools:

PME online mode with breakpoint debug,DeltaV Diagnostics Station,AMS Device Manager for HART instrument health,Movicon NExT SCADA diagnostics,Profinet / EtherNet/IP topology tools,Trace tool with multi-channel capture,Hot-standby pair status diagnostics,Emerson global service desk support,Project-comparison and version-control integration,TÜV functional-safety audit-trail tooling

Use the monitoring and diagnostic functions available in your PAC Machine Edition / Movicon NExT / DeltaV Studio version, and record the software, firmware, hardware, workload, and test procedure with every result.

Emerson Function Blocks Example for Packaging Automation

Illustrative Function Blocks example for Packaging Automation using Emerson terminology. Adapt the syntax to your PAC Machine Edition / Movicon NExT / DeltaV Studio release, compile it, and verify it in an isolated test environment before use on equipment.

(* Emerson PAC Machine Edition / Movicon NExT / DeltaV Studio - Packaging Automation Control *)
(* Reusable Function Blocks Implementation *)
(* PME FB libraries cover motion, drives, communications, safet *)

FUNCTION_BLOCK FB_PACKAGING_AUTOMATION_Controller

VAR_INPUT
    bEnable : BOOL;                  (* Enable control *)
    bReset : BOOL;                   (* Fault reset *)
    rProcessValue : REAL;            (* Product detection sensors for counting and positioning *)
    rSetpoint : REAL := 100.0;  (* Illustrative value; replace with a reviewed requirement *)
    bEmergencyStop : BOOL;           (* Safety input *)
END_VAR

VAR_OUTPUT
    rControlOutput : REAL;           (* Servo drives for precise motion control *)
    bRunning : BOOL;                 (* Process active *)
    bComplete : BOOL;                (* Cycle complete *)
    bFault : BOOL;                   (* Fault status *)
    nFaultCode : INT;                (* Diagnostic code *)
END_VAR

VAR
    (* Internal Function Blocks *)
    fbSafety : FB_SafetyMonitor;     (* Safety logic *)
    fbRamp : FB_RampGenerator;       (* Soft start/stop *)
    fbPID : FB_PIDController;        (* Process control *)
    fbDiag : FB_Diagnostics;         (* PME alarms are flagged via library FBs into Movicon / Wonderware / Experion-equivalent SCADA. DeltaV alarms use the platform alarm-config with severity, suppression, and audit logging. *)

    (* Internal State *)
    eInternalState : E_ControlState;
    tonWatchdog : TON;
END_VAR

(* Safety Monitor - Guarding around rotating and reciprocating parts *)
fbSafety(
    Enable := bEnable,
    EmergencyStop := bEmergencyStop,
    ProcessValue := rProcessValue,
    HighLimit := rSetpoint * 1.2,
    LowLimit := rSetpoint * 0.1
);

(* Main Control Logic *)
IF fbSafety.SafeToRun THEN
    (* Ramp Generator - Prevents startup surge *)
    fbRamp(
        Enable := bEnable,
        TargetValue := rSetpoint,
        RampRate := 20.0,  (* Illustrative value; tune and verify for the process *)
        CurrentValue => rSetpoint
    );

    (* PID Controller - Process regulation *)
    fbPID(
        Enable := fbRamp.InPosition,
        ProcessValue := rProcessValue,
        Setpoint := fbRamp.CurrentValue,
        Kp := 1.0,
        Ki := 0.1,
        Kd := 0.05,
        OutputMin := 0.0,
        OutputMax := 100.0
    );

    rControlOutput := fbPID.Output;
    bRunning := TRUE;
    bFault := FALSE;
    nFaultCode := 0;

ELSE
    (* Safe State - Safety-rated position monitoring for setup access *)
    rControlOutput := 0.0;
    bRunning := FALSE;
    bFault := NOT bEnable;  (* Only fault if not intentional stop *)
    nFaultCode := fbSafety.FaultCode;
END_IF;

(* Diagnostics - PME data logging via Movicon NExT or PI historian; DeltaV uses Continuous Historian as the native logging tier. *)
fbDiag(
    ProcessRunning := bRunning,
    FaultActive := bFault,
    ProcessValue := rProcessValue,
    ControlOutput := rControlOutput
);

(* Watchdog - Detects frozen control *)
tonWatchdog(IN := bRunning AND NOT fbPID.OutputChanging, PT := T#10S);
IF tonWatchdog.Q THEN
    bFault := TRUE;
    nFaultCode := 99;  (* Watchdog fault *)
END_IF;

(* Reset Logic *)
IF bReset AND NOT bEmergencyStop THEN
    bFault := FALSE;
    nFaultCode := 0;
    fbDiag.ClearAlarms();
END_IF;

END_FUNCTION_BLOCK

Code Explanation:

  • 1.Encapsulated function block follows PME FB libraries cover motion, drives, c - reusable across Packaging projects
  • 2.FB_SafetyMonitor illustrates status checks and high/low limits; it is not a certified safety function
  • 3.FB_RampGenerator prevents startup issues common in Packaging Automation systems
  • 4.FB_PIDController tuned for Packaging: Kp=1.0, Ki=0.1
  • 5.Watchdog timer illustrates one way to flag an unchanged output for diagnosis
  • 6.Diagnostic function block enables PME data logging via Movicon NExT or PI historian; DeltaV uses Continuous Historian as the native logging tier. and PME alarms are flagged via library FBs into Movicon / Wonderware / Experion-equivalent SCADA. DeltaV alarms use the platform alarm-config with severity, suppression, and audit logging.

Best Practices

  • Follow Emerson naming conventions: PME projects in former-GE plants often retain GE-style raw memory references (%I
  • Emerson function design: PME FB libraries cover motion, drives, communications, safety. DeltaV control-mo
  • Data organization: Structured types in PME for axis status, recipe, and instrument data. DeltaV use
  • Function Blocks: Arrange blocks for clear left-to-right data flow
  • Function Blocks: Use consistent spacing and alignment for readability
  • Function Blocks: Label all inputs and outputs with meaningful names
  • Packaging Automation: Use electronic gearing for mechanical simplicity
  • Packaging Automation: Implement automatic film/label splice detection
  • Packaging Automation: Add statistical monitoring of registration error
  • Debug with PAC Machine Edition / Movicon NExT / DeltaV Studio: Use PME online mode with breakpoints for IEC POU debug; use C-FB build
  • Safety: Guarding around rotating and reciprocating parts
  • Use a compatible simulator or isolated test rig to test Packaging Automation logic before deployment

Common Pitfalls to Avoid

  • Function Blocks: Creating feedback loops without proper initialization
  • Function Blocks: Connecting incompatible data types
  • Function Blocks: Not considering execution order dependencies
  • Emerson common error: GE-legacy raw-address symbolic conflicts after migration to PME
  • Packaging Automation: Maintaining registration at high speeds
  • Packaging Automation: Handling product variability in automated systems
  • Neglecting to validate Product detection sensors for counting and positioning leads to control errors
  • Insufficient comments make Function Blocks programs unmaintainable over time

Related Certifications

🏆Emerson PACSystems Certified Engineer
🏆DeltaV Certified Professional
🏆TÜV Functional Safety Engineer (Emerson-specific)
🏆Movicon SCADA certified developer
🏆Advanced Emerson Programming Certification

Applying Function Blocks to Packaging Automation using Emerson PAC Machine Edition / Movicon NExT / DeltaV Studio requires understanding the platform, the process, and the project's acceptance criteria. This guide has covered implementation structure, an illustrative code example, verification practices, and common pitfalls for a intermediate to advanced Packaging Automation exercise.

Use the practices outlined here to create a design that can be reviewed and tested. Define performance targets in the project requirements and confirm them with repeatable measurements.

Next Steps:

1. Check Sources: Read the current PAC Machine Edition / Movicon NExT / DeltaV Studio help, controller manual, release notes, and relevant standards
2. Practice Safely: Adapt the example in a simulator or isolated training setup
3. Review: Have the I/O map, state behavior, faults, and recovery steps reviewed
4. Test: Record normal, boundary, fault, restart, and communications test results

Function Blocks Foundation:

Function Block Diagram (FBD) is a graphical programming language where functions and function blocks are represented as boxes connected by signal line...

Project duration depends on scope, reviews, hardware availability, software and firmware versions, testing, commissioning, and site constraints. Remember: Use electronic gearing for mechanical simplicity

For further learning, explore related topics including Temperature control, Pharmaceutical blister packing, and Emerson platform-specific features for Packaging Automation optimization.