Learn PLCs free
Intermediate20 min readPackaging

Delta Sequential Function Charts (SFC) for Packaging Automation

Learn Sequential Function Charts (SFC) programming for Packaging Automation using Delta WPLSoft / ISPSoft / DIADesigner-AX. Includes code examples, best practices, and step-by-step implementation guide for Packaging applications.

💻
Platform
WPLSoft / ISPSoft / DIADesigner-AX
📊
Complexity
Intermediate to Advanced
⏱️
Project Duration
3-6 weeks

Troubleshooting Sequential Function Charts (SFC) programs for Packaging Automation in Delta's WPLSoft / ISPSoft / DIADesigner-AX benefits from a systematic diagnostic process and a clear understanding of likely failure modes. This guide provides a repeatable path from observed symptom to evidence, hypothesis, controlled test, and documented correction.

Start by recording the controller model, firmware, WPLSoft / ISPSoft / DIADesigner-AX version, task state, active faults, I/O status, and the exact conditions that reproduce the problem. Preserve the original project and collect diagnostic evidence before changing logic.

Common challenges in Packaging Automation systems include product changeover, high-speed synchronization, and product tracking. When implemented with Sequential Function Charts (SFC), additional considerations include limited to sequential operations, requiring specific diagnostic approaches. Delta's diagnostic tools in WPLSoft / ISPSoft / DIADesigner-AX provide powerful capabilities, but knowing exactly which tools to use for specific symptoms dramatically improves troubleshooting efficiency.

This guide walks through systematic troubleshooting procedures, from initial symptom analysis through root-cause verification and corrective-action testing. It explains how to use relevant WPLSoft / ISPSoft / DIADesigner-AX diagnostic features and interpret system behavior in a Packaging Automation context without assuming that one symptom always has the same cause.

Delta WPLSoft / ISPSoft / DIADesigner-AX for Packaging Automation

WPLSoft / ISPSoft / DIADesigner-AX is a programming environment associated with Delta controller families such as DVP-ES2 / EX2 / SS2 (compact entry), DVP-SX2 / SA2 / SV2 (motion + analogue), DVP-SE (Ethernet). This guide uses Sequential Function Charts (SFC) terminology from the supplied guide dataset, but controller capabilities and language support can change by model, firmware, software edition, and license.

Verify Before You Start:

  • The selected controller supports the required Sequential Function Charts (SFC) constructs

  • The project version matches the installed WPLSoft / ISPSoft / DIADesigner-AX release

  • Required communications, motion, safety, and simulation options are licensed

  • Firmware and device-description files are compatible with the project

  • The vendor manuals used for the design match the exact hardware revision


Application Planning:

For a Packaging Automation exercise, map the required inputs and outputs before writing logic. The example considers 5 sensor types, including Vision systems, Weight sensors, Barcode scanners, and 5 actuator types.

Control Equipment for Packaging Automation:

  • Form-fill-seal machines (horizontal and vertical)

  • Case erectors and sealers

  • Labeling systems (pressure sensitive, shrink sleeve)

  • Case packers (drop, wrap-around, robotic)


Controller-family references used in this guide include:

  • DVP-ES2 / EX2 / SS2 (compact entry): Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide

  • DVP-SX2 / SA2 / SV2 (motion + analogue): Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide

  • DVP-SE (Ethernet): Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide

  • DVP-EH3 (legacy high-end): Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide


Hardware Selection Checklist:

  • Count local and remote I/O, including planned expansion

  • Measure the required task and communications update rates

  • Identify memory, data-retention, diagnostics, and cybersecurity requirements

  • Treat safety functions as a separate, standards-led design activity

  • Confirm lifecycle status, regional availability, licensing, and support


Source and Validation Note:

This page does not represent a vendor certification or a hardware acceptance test. Use current Delta manuals, release notes, and safety documentation as the authority for product-specific behavior. Validate adapted logic in a simulator or isolated test setup before connecting it to equipment.

Investment Considerations:

For Packaging Automation projects, compare hardware, software licensing, training, engineering, test equipment, commissioning, spares, and ongoing support. Obtain current pricing and lifecycle information directly from the vendor or an authorized regional supplier.

Understanding Sequential Function Charts (SFC) for Packaging Automation

Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by transitions, ideal for batch processes and machine sequences.

Execution Model:

Only active steps execute their actions. Transitions define conditions for moving between steps. Multiple steps can be active simultaneously in parallel branches.

Core Advantages for Packaging Automation:

  • Perfect for sequential processes: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Clear visualization of process flow: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Easy to understand process steps: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Good for batch operations: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Simplifies complex sequences: Critical for Packaging Automation when handling intermediate to advanced control logic


Why Sequential Function Charts (SFC) Fits Packaging Automation:

Packaging Automation systems in Packaging typically involve:

  • Sensors: Product detection sensors for counting and positioning, Registration sensors for label and film alignment, Barcode/2D code readers for verification

  • Actuators: Servo drives for precise motion control, Pneumatic cylinders for pick-and-place, Vacuum generators and cups

  • Complexity: Intermediate to Advanced with challenges including Maintaining registration at high speeds


Programming Fundamentals in Sequential Function Charts (SFC):

Steps:
- initialStep: Double-bordered box - starting point of sequence, active on program start
- normalStep: Single-bordered box - becomes active when preceding transition fires
- actions: Associated code that executes while step is active

Transitions:
- condition: Boolean expression that must be TRUE to advance
- firing: Transition fires when preceding step is active AND condition is TRUE
- priority: In selective branches, transitions are evaluated in defined order

ActionQualifiers:
- N: Non-stored - executes while step is active
- S: Set - sets output TRUE on step entry, remains TRUE
- R: Reset - sets output FALSE on step entry

Best Practices for Sequential Function Charts (SFC):

  • Start with a clear process flow diagram before implementing SFC

  • Use descriptive step names indicating what happens (e.g., Filling, Heating)

  • Keep transition conditions simple - complex logic goes in action code

  • Implement timeout transitions to prevent stuck sequences

  • Always provide a path back to initial step for reset/restart


Common Mistakes to Avoid:

  • Forgetting to include stop/abort transitions for emergency handling

  • Creating deadlocks where no transition can fire

  • Not handling the case where transition conditions never become TRUE

  • Using S (Set) actions without corresponding R (Reset) actions


Typical Applications:

1. Bottle filling: Directly applicable to Packaging Automation
2. Assembly sequences: Related control patterns
3. Material handling: Related control patterns
4. Batch mixing: Related control patterns

Understanding these fundamentals prepares you to implement effective Sequential Function Charts (SFC) solutions for Packaging Automation using Delta WPLSoft / ISPSoft / DIADesigner-AX.

Implementing Packaging Automation with Sequential Function Charts (SFC)

Packaging automation systems use PLCs to coordinate primary, secondary, and tertiary packaging operations. These systems control filling, labeling, case packing, palletizing, and integration with production and warehouse systems.

This walkthrough demonstrates practical implementation using Delta WPLSoft / ISPSoft / DIADesigner-AX and Sequential Function Charts (SFC) programming.

System Requirements:

A typical Packaging Automation implementation includes:

Input Devices (Sensors):
1. Product detection sensors for counting and positioning: Critical for monitoring system state
2. Registration sensors for label and film alignment: Critical for monitoring system state
3. Barcode/2D code readers for verification: Critical for monitoring system state
4. Vision systems for quality inspection: Critical for monitoring system state
5. Reject confirmation sensors: Critical for monitoring system state

Output Devices (Actuators):
1. Servo drives for precise motion control: Primary control output
2. Pneumatic cylinders for pick-and-place: Supporting control function
3. Vacuum generators and cups: Supporting control function
4. Glue and tape applicators: Supporting control function
5. Film tensioners and seal bars: Supporting control function

Control Equipment:

  • Form-fill-seal machines (horizontal and vertical)

  • Case erectors and sealers

  • Labeling systems (pressure sensitive, shrink sleeve)

  • Case packers (drop, wrap-around, robotic)


Control Strategies for Packaging Automation:

1. Primary Control: Automated packaging systems using PLCs for product wrapping, boxing, labeling, and palletizing.
2. Safety Interlocks: Preventing Product changeover
3. Error Recovery: Handling High-speed synchronization

Implementation Steps:

Step 1: Define packaging specifications for all product variants

In WPLSoft / ISPSoft / DIADesigner-AX, define packaging specifications for all product variants.

Step 2: Create motion profiles for each packaging format

In WPLSoft / ISPSoft / DIADesigner-AX, create motion profiles for each packaging format.

Step 3: Implement registration control with encoder feedback

In WPLSoft / ISPSoft / DIADesigner-AX, implement registration control with encoder feedback.

Step 4: Program pattern generation for case and pallet loading

In WPLSoft / ISPSoft / DIADesigner-AX, program pattern generation for case and pallet loading.

Step 5: Add reject handling with confirmation logic

In WPLSoft / ISPSoft / DIADesigner-AX, add reject handling with confirmation logic.

Step 6: Implement barcode/vision integration for verification

In WPLSoft / ISPSoft / DIADesigner-AX, implement barcode/vision integration for verification.


Delta Function Design:

WPLSoft P-labels are the primary reuse mechanism on DVP. ISPSoft instance-based function blocks enable proper IEC-style reuse on AH / AS, with library import / export. Delta-supplied motion, communication, and PID FBs ship with the IDE.

Common Challenges and Solutions:

1. Maintaining registration at high speeds

  • Solution: Sequential Function Charts (SFC) addresses this through Perfect for sequential processes.


2. Handling product variability in automated systems

  • Solution: Sequential Function Charts (SFC) addresses this through Clear visualization of process flow.


3. Quick changeover between package formats

  • Solution: Sequential Function Charts (SFC) addresses this through Easy to understand process steps.


4. Synchronizing multiple machines in a line

  • Solution: Sequential Function Charts (SFC) addresses this through Good for batch operations.


Safety Considerations:

  • Guarding around rotating and reciprocating parts

  • Safety-rated position monitoring for setup access

  • Heat hazard protection for seal bars and shrink tunnels

  • Proper pinch point guarding

  • Robot safety zones and light curtains


Performance Metrics:

  • Task and I/O timing: Record minimum, average, and maximum values under a defined test load

  • Accuracy: Define an acceptable tolerance and compare it with calibrated reference measurements

  • Throughput: Count completed cycles over a fixed interval and record rejected or incomplete cycles

  • Fault response: Measure detection, safe-state, alarm, and recovery behavior for each test case

  • Resource use: Record memory, communications load, and diagnostic-buffer behavior

Delta Diagnostic Tools:

WPLSoft / ISPSoft online monitor with rung-state colour,Soft-element watch table and tag watch lists,Built-in offline simulator (WPLSoft and ISPSoft),Modbus RTU / TCP communication wizard with diagnostic counters,DIADesigner-AX integrated diagnostics for AX motion projects,M1000-range system flags for CPU and comms diagnostics,Delta distributor support and loaner CPUs in major markets,Delta IA forum and DeltaPLC community for application questions

Use the monitoring and diagnostic functions available in your WPLSoft / ISPSoft / DIADesigner-AX version, and record the software, firmware, hardware, workload, and test procedure with every result.

Delta Sequential Function Charts (SFC) Example for Packaging Automation

Illustrative Sequential Function Charts (SFC) example for Packaging Automation using Delta terminology. Adapt the syntax to your WPLSoft / ISPSoft / DIADesigner-AX release, compile it, and verify it in an isolated test environment before use on equipment.

// Delta WPLSoft / ISPSoft / DIADesigner-AX - Packaging Automation Control
// Sequential Function Charts (SFC) Implementation for Packaging
// WPLSoft / DVP work is dominated by raw soft-element addressi

// ============================================
// Variable Declarations
// ============================================
VAR
    bEnable : BOOL := FALSE;
    bEmergencyStop : BOOL := FALSE;
    rVisionsystems : REAL;
    rServomotors : REAL;
END_VAR

// ============================================
// Input Conditioning - Product detection sensors for counting and positioning
// ============================================
// Standard input processing
IF rVisionsystems > 0.0 THEN
    bEnable := TRUE;
END_IF;

// ============================================
// Safety Interlock - Guarding around rotating and reciprocating parts
// ============================================
IF bEmergencyStop THEN
    rServomotors := 0.0;
    bEnable := FALSE;
END_IF;

// ============================================
// Main Packaging Automation Control Logic
// ============================================
IF bEnable AND NOT bEmergencyStop THEN
    // Packaging automation systems use PLCs to coordinate primary,
    rServomotors := rVisionsystems * 1.0; (* Illustrative scaling only *)

    // Process monitoring
    // Add specific control logic here
ELSE
    rServomotors := 0.0;
END_IF;

Code Explanation:

  • 1.Sequential Function Charts (SFC) structure organized for a Packaging Automation training example
  • 2.Input conditioning handles Product detection sensors for counting and positioning signals
  • 3.Safety interlock ensures Guarding around rotating and reciprocating parts always takes priority
  • 4.Main control implements Packaging automation systems use PLCs to
  • 5.Adapt the scan-cycle assumptions to the selected DVP-ES2 / EX2 / SS2 (compact entry) task configuration and verify them by measurement

Best Practices

  • Follow Delta naming conventions: WPLSoft / DVP work is dominated by raw soft-element addressing (X0, Y0, M100, D1
  • Delta function design: WPLSoft P-labels are the primary reuse mechanism on DVP. ISPSoft instance-based
  • Data organization: DVP has no structured data blocks — D / register banks are documented by range.
  • Sequential Function Charts (SFC): Start with a clear process flow diagram before implementing SFC
  • Sequential Function Charts (SFC): Use descriptive step names indicating what happens (e.g., Filling, Heating)
  • Sequential Function Charts (SFC): Keep transition conditions simple - complex logic goes in action code
  • Packaging Automation: Use electronic gearing for mechanical simplicity
  • Packaging Automation: Implement automatic film/label splice detection
  • Packaging Automation: Add statistical monitoring of registration error
  • Debug with WPLSoft / ISPSoft / DIADesigner-AX: Run the offline simulator with forced inputs before live download
  • Safety: Guarding around rotating and reciprocating parts
  • Use a compatible simulator or isolated test rig to test Packaging Automation logic before deployment

Common Pitfalls to Avoid

  • Sequential Function Charts (SFC): Forgetting to include stop/abort transitions for emergency handling
  • Sequential Function Charts (SFC): Creating deadlocks where no transition can fire
  • Sequential Function Charts (SFC): Not handling the case where transition conditions never become TRUE
  • Delta common error: Battery-low alarm on legacy DVP-EH causing D-range data loss
  • Packaging Automation: Maintaining registration at high speeds
  • Packaging Automation: Handling product variability in automated systems
  • Neglecting to validate Product detection sensors for counting and positioning leads to control errors
  • Insufficient comments make Sequential Function Charts (SFC) programs unmaintainable over time

Related Certifications

🏆Delta IA Academy distributor-led engineer training
🏆WPLSoft / ISPSoft course completions
🏆DIADesigner-AX motion specialist tracks for AX-series engineers

Applying Sequential Function Charts (SFC) to Packaging Automation using Delta WPLSoft / ISPSoft / DIADesigner-AX requires understanding the platform, the process, and the project's acceptance criteria. This guide has covered implementation structure, an illustrative code example, verification practices, and common pitfalls for a intermediate to advanced Packaging Automation exercise.

Use the practices outlined here to create a design that can be reviewed and tested. Define performance targets in the project requirements and confirm them with repeatable measurements.

Next Steps:

1. Check Sources: Read the current WPLSoft / ISPSoft / DIADesigner-AX help, controller manual, release notes, and relevant standards
2. Practice Safely: Adapt the example in a simulator or isolated training setup
3. Review: Have the I/O map, state behavior, faults, and recovery steps reviewed
4. Test: Record normal, boundary, fault, restart, and communications test results

Sequential Function Charts (SFC) Foundation:

Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by tran...

Project duration depends on scope, reviews, hardware availability, software and firmware versions, testing, commissioning, and site constraints. Remember: Use electronic gearing for mechanical simplicity

For further learning, explore related topics including Assembly sequences, Pharmaceutical blister packing, and Delta platform-specific features for Packaging Automation optimization.