Learn PLCs free
Advanced20 min readUniversal

Siemens Sequential Function Charts (SFC) for Safety Systems

Learn Sequential Function Charts (SFC) programming for Safety Systems using Siemens TIA Portal. Includes code examples, best practices, and step-by-step implementation guide for Universal applications.

💻
Platform
TIA Portal
📊
Complexity
Advanced
⏱️
Project Duration
4-8 weeks

Optimizing Sequential Function Charts (SFC) for Safety Systems applications in Siemens's TIA Portal requires measuring the baseline and understanding the demands of Universal. This guide focuses on techniques you can evaluate with task timing, scan-time traces, memory use, and controlled fault tests.

For advanced applications like Safety Systems, check which diagnostics and profiling tools are available in your installed TIA Portal version. Controller model, firmware, task configuration, communications, and I/O update behavior can all affect the result.

Performance considerations for Safety Systems systems extend beyond basic functionality. Critical factors include 5 sensor types, 4 actuators, communications load, and the need to handle safety integrity level (sil) compliance. Evaluate whether perfect for sequential processes helps the design, then measure the actual task and I/O timing on the selected configuration.

This guide covers memory management, execution order, Sequential Function Charts (SFC)-specific tuning, and a repeatable measurement plan for Safety Systems applications. Treat every optimization as a hypothesis: record the baseline, change one variable, retest the same workload, and keep the change only when the measured result and code maintainability both improve.

Siemens TIA Portal for Safety Systems

TIA Portal is a programming environment associated with Siemens controller families such as S7-1200, S7-1500, S7-300. This guide uses Sequential Function Charts (SFC) terminology from the supplied guide dataset, but controller capabilities and language support can change by model, firmware, software edition, and license.

Verify Before You Start:

  • The selected controller supports the required Sequential Function Charts (SFC) constructs

  • The project version matches the installed TIA Portal release

  • Required communications, motion, safety, and simulation options are licensed

  • Firmware and device-description files are compatible with the project

  • The vendor manuals used for the design match the exact hardware revision


Application Planning:

For a Safety Systems exercise, map the required inputs and outputs before writing logic. The example considers 5 sensor types, including Safety light curtains, Emergency stop buttons, Safety door switches, and 4 actuator types.

Control Equipment for Safety Systems:

  • Safety PLCs (fail-safe controllers)

  • Safety relays (configurable or fixed)

  • Safety I/O modules with diagnostics

  • Safety network protocols (PROFIsafe, CIP Safety)


Controller-family references used in this guide include:

  • S7-1200: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide

  • S7-1500: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide

  • S7-300: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide

  • S7-400: Confirm CPU, I/O, memory, communications, and Sequential Function Charts (SFC) support in the current selection guide


Hardware Selection Checklist:

  • Count local and remote I/O, including planned expansion

  • Measure the required task and communications update rates

  • Identify memory, data-retention, diagnostics, and cybersecurity requirements

  • Treat safety functions as a separate, standards-led design activity

  • Confirm lifecycle status, regional availability, licensing, and support


Source and Validation Note:

This page does not represent a vendor certification or a hardware acceptance test. Use current Siemens manuals, release notes, and safety documentation as the authority for product-specific behavior. Validate adapted logic in a simulator or isolated test setup before connecting it to equipment.

Investment Considerations:

For Safety Systems projects, compare hardware, software licensing, training, engineering, test equipment, commissioning, spares, and ongoing support. Obtain current pricing and lifecycle information directly from the vendor or an authorized regional supplier.

Understanding Sequential Function Charts (SFC) for Safety Systems

Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by transitions, ideal for batch processes and machine sequences.

Execution Model:

Only active steps execute their actions. Transitions define conditions for moving between steps. Multiple steps can be active simultaneously in parallel branches.

Core Advantages for Safety Systems:

  • Perfect for sequential processes: Critical for Safety Systems when handling advanced control logic

  • Clear visualization of process flow: Critical for Safety Systems when handling advanced control logic

  • Easy to understand process steps: Critical for Safety Systems when handling advanced control logic

  • Good for batch operations: Critical for Safety Systems when handling advanced control logic

  • Simplifies complex sequences: Critical for Safety Systems when handling advanced control logic


Why Sequential Function Charts (SFC) Fits Safety Systems:

Safety Systems systems in Universal typically involve:

  • Sensors: Emergency stop buttons (Category 0 or 1 stop), Safety light curtains (Type 2 or Type 4), Safety laser scanners for zone detection

  • Actuators: Safety contactors (mirror contact type), Safe torque off (STO) drives, Safety brake modules

  • Complexity: Advanced with challenges including Achieving required safety level with practical architecture


Programming Fundamentals in Sequential Function Charts (SFC):

Steps:
- initialStep: Double-bordered box - starting point of sequence, active on program start
- normalStep: Single-bordered box - becomes active when preceding transition fires
- actions: Associated code that executes while step is active

Transitions:
- condition: Boolean expression that must be TRUE to advance
- firing: Transition fires when preceding step is active AND condition is TRUE
- priority: In selective branches, transitions are evaluated in defined order

ActionQualifiers:
- N: Non-stored - executes while step is active
- S: Set - sets output TRUE on step entry, remains TRUE
- R: Reset - sets output FALSE on step entry

Best Practices for Sequential Function Charts (SFC):

  • Start with a clear process flow diagram before implementing SFC

  • Use descriptive step names indicating what happens (e.g., Filling, Heating)

  • Keep transition conditions simple - complex logic goes in action code

  • Implement timeout transitions to prevent stuck sequences

  • Always provide a path back to initial step for reset/restart


Common Mistakes to Avoid:

  • Forgetting to include stop/abort transitions for emergency handling

  • Creating deadlocks where no transition can fire

  • Not handling the case where transition conditions never become TRUE

  • Using S (Set) actions without corresponding R (Reset) actions


Typical Applications:

1. Bottle filling: Directly applicable to Safety Systems
2. Assembly sequences: Related control patterns
3. Material handling: Related control patterns
4. Batch mixing: Related control patterns

Understanding these fundamentals prepares you to implement effective Sequential Function Charts (SFC) solutions for Safety Systems using Siemens TIA Portal.

Implementing Safety Systems with Sequential Function Charts (SFC)

Safety system control uses safety-rated PLCs and components to protect personnel and equipment from hazardous conditions. These systems implement safety functions per IEC 62443 and ISO 13849 standards with redundancy and diagnostics.

This walkthrough demonstrates practical implementation using Siemens TIA Portal and Sequential Function Charts (SFC) programming.

System Requirements:

A typical Safety Systems implementation includes:

Input Devices (Sensors):
1. Emergency stop buttons (Category 0 or 1 stop): Critical for monitoring system state
2. Safety light curtains (Type 2 or Type 4): Critical for monitoring system state
3. Safety laser scanners for zone detection: Critical for monitoring system state
4. Safety interlock switches (tongue, hinged, trapped key): Critical for monitoring system state
5. Safety mats and edges: Critical for monitoring system state

Output Devices (Actuators):
1. Safety contactors (mirror contact type): Primary control output
2. Safe torque off (STO) drives: Supporting control function
3. Safety brake modules: Supporting control function
4. Lock-out valve manifolds: Supporting control function
5. Safety relay outputs: Supporting control function

Control Equipment:

  • Safety PLCs (fail-safe controllers)

  • Safety relays (configurable or fixed)

  • Safety I/O modules with diagnostics

  • Safety network protocols (PROFIsafe, CIP Safety)


Control Strategies for Safety Systems:

1. Primary Control: Safety-rated PLC programming for personnel protection, emergency stops, and safety interlocks per IEC 61508/61511.
2. Safety Interlocks: Preventing Safety integrity level (SIL) compliance
3. Error Recovery: Handling Redundancy requirements

Implementation Steps:

Step 1: Perform hazard analysis and risk assessment

In TIA Portal, perform hazard analysis and risk assessment.

Step 2: Determine required safety level (SIL/PL) for each function

In TIA Portal, determine required safety level (sil/pl) for each function.

Step 3: Select certified safety components meeting requirements

In TIA Portal, select certified safety components meeting requirements.

Step 4: Design safety circuit architecture per category requirements

In TIA Portal, design safety circuit architecture per category requirements.

Step 5: Implement safety logic in certified safety PLC/relay

In TIA Portal, implement safety logic in certified safety plc/relay.

Step 6: Add diagnostics and proof test provisions

In TIA Portal, add diagnostics and proof test provisions.


Siemens Function Design:

Functions (FCs) and Function Blocks (FBs) form the modular building blocks of structured Siemens programs. FCs are stateless code blocks without persistent memory, suitable for calculations, data conversions, or operations that don't require retaining values between calls. FC parameters include IN for input values, OUT for returned results, IN_OUT for passed pointers to existing variables, and TEMP for temporary calculations discarded after execution. Return values are defined using the RETURN data type declaration. FBs contain STAT (static) variables that persist between scan cycles, stored in instance DBs, making them ideal for controlling equipment with ongoing state like motors, valves, or process loops. Multi-instance FBs reduce memory overhead by embedding multiple FB instances within a parent FB's instance DB. The block interface clearly separates Input, Output, InOut, Stat (persistent), Temp (temporary), and Constant sections. FB parameters should include Enable inputs, feedback status outputs, error outputs with diagnostic codes, and configuration parameters for setpoints and timings. Versioned FBs in Type Libraries support interface extensions while maintaining backward compatibility using optional parameters with default values. Generic FB designs incorporate enumerated data types (ENUM) for state machines: WAITING, RUNNING, STOPPING, FAULTED. Call structures pass instance DB references explicitly: Motor_FB(DB1) or multi-instances as Motor_FB.Instance[1]. SCL (Structured Control Language) provides text-based programming within FCs/FBs for complex algorithms, offering better readability than ladder for mathematical operations and CASE statements. Block properties define code attributes: Know-how protection encrypts proprietary logic, version information tracks revisions, and block icons customize graphic representation in calling networks.

Common Challenges and Solutions:

1. Achieving required safety level with practical architecture

  • Solution: Sequential Function Charts (SFC) addresses this through Perfect for sequential processes.


2. Managing nuisance trips while maintaining safety

  • Solution: Sequential Function Charts (SFC) addresses this through Clear visualization of process flow.


3. Integrating safety with production efficiency

  • Solution: Sequential Function Charts (SFC) addresses this through Easy to understand process steps.


4. Documenting compliance with multiple standards

  • Solution: Sequential Function Charts (SFC) addresses this through Good for batch operations.


Safety Considerations:

  • Use only certified safety components and PLCs

  • Implement dual-channel monitoring per category requirements

  • Add diagnostic coverage to detect latent faults

  • Design for fail-safe operation (de-energize to trip)

  • Provide regular proof testing of safety functions


Performance Metrics:

  • Task and I/O timing: Record minimum, average, and maximum values under a defined test load

  • Accuracy: Define an acceptable tolerance and compare it with calibrated reference measurements

  • Throughput: Count completed cycles over a fixed interval and record rejected or incomplete cycles

  • Fault response: Measure detection, safe-state, alarm, and recovery behavior for each test case

  • Resource use: Record memory, communications load, and diagnostic-buffer behavior

Siemens Diagnostic Tools:

Program Status: Real-time monitoring showing actual rung logic states with green highlights for TRUE conditions and value displays,Force Tables: Override inputs/outputs permanently (use with extreme caution, indicated by warning icons),Modify Variable: Temporarily change tag values in online mode for testing without redownload,Trace & Watch Tables: Record up to 50 variables synchronously with 1ms resolution, triggered by conditions,Diagnostic Buffer: Chronological log of 200 system events including mode changes, errors, and module diagnostics,ProDiag Viewer: Displays user-configured diagnostic messages with operator guidance and troubleshooting steps,Web Server Diagnostics: Browser-based access to buffer, topology, communication load, and module status,PROFINET Topology: Live view of network with link quality, update times, and neighbor relationships,Memory Usage Statistics: Real-time display of work memory, load memory, and retentive memory consumption,Communication Diagnostics: Connection statistics, telegram counters, and partner unreachable conditions,Test & Commissioning Functions: Actuator testing, sensor simulation, and step-by-step execution modes,Reference Data Cross-Reference: Shows all code locations using specific variables, DBs, or I/O addresses

Use the monitoring and diagnostic functions available in your TIA Portal version, and record the software, firmware, hardware, workload, and test procedure with every result.

Siemens Sequential Function Charts (SFC) Example for Safety Systems

Illustrative Sequential Function Charts (SFC) example for Safety Systems using Siemens terminology. Adapt the syntax to your TIA Portal release, compile it, and verify it in an isolated test environment before use on equipment.

// Siemens TIA Portal - Safety Systems Control
// Sequential Function Charts (SFC) Implementation for Universal
// Siemens recommends structured naming conventions using the P

// ============================================
// Variable Declarations
// ============================================
VAR
    bEnable : BOOL := FALSE;
    bEmergencyStop : BOOL := FALSE;
    rSafetylightcurtains : REAL;
    rSafetyrelays : REAL;
END_VAR

// ============================================
// Input Conditioning - Emergency stop buttons (Category 0 or 1 stop)
// ============================================
// Standard input processing
IF rSafetylightcurtains > 0.0 THEN
    bEnable := TRUE;
END_IF;

// ============================================
// Safety Interlock - Use only certified safety components and PLCs
// ============================================
IF bEmergencyStop THEN
    rSafetyrelays := 0.0;
    bEnable := FALSE;
END_IF;

// ============================================
// Main Safety Systems Control Logic
// ============================================
IF bEnable AND NOT bEmergencyStop THEN
    // Safety system control uses safety-rated PLCs and components 
    rSafetyrelays := rSafetylightcurtains * 1.0; (* Illustrative scaling only *)

    // Process monitoring
    // Add specific control logic here
ELSE
    rSafetyrelays := 0.0;
END_IF;

Code Explanation:

  • 1.Sequential Function Charts (SFC) structure organized for a Safety Systems training example
  • 2.Input conditioning handles Emergency stop buttons (Category 0 or 1 stop) signals
  • 3.Safety interlock ensures Use only certified safety components and PLCs always takes priority
  • 4.Main control implements Safety system control uses safety-rated
  • 5.Adapt the scan-cycle assumptions to the selected S7-1200 task configuration and verify them by measurement

Best Practices

  • Follow Siemens naming conventions: Siemens recommends structured naming conventions using the PLC tag table with sy
  • Siemens function design: Functions (FCs) and Function Blocks (FBs) form the modular building blocks of st
  • Data organization: Data Blocks (DBs) are fundamental to Siemens programming, serving as structured
  • Sequential Function Charts (SFC): Start with a clear process flow diagram before implementing SFC
  • Sequential Function Charts (SFC): Use descriptive step names indicating what happens (e.g., Filling, Heating)
  • Sequential Function Charts (SFC): Keep transition conditions simple - complex logic goes in action code
  • Safety Systems: Keep safety logic simple and auditable
  • Safety Systems: Use certified function blocks from safety PLC vendor
  • Safety Systems: Implement cross-monitoring between channels
  • Debug with TIA Portal: Use CALL_TRACE to identify the call hierarchy leading to errors in dee
  • Safety: Use only certified safety components and PLCs
  • Use a compatible simulator or isolated test rig to test Safety Systems logic before deployment

Common Pitfalls to Avoid

  • Sequential Function Charts (SFC): Forgetting to include stop/abort transitions for emergency handling
  • Sequential Function Charts (SFC): Creating deadlocks where no transition can fire
  • Sequential Function Charts (SFC): Not handling the case where transition conditions never become TRUE
  • Siemens common error: 16#8022: DB does not exist or is too short - called DB number not loaded or inte
  • Safety Systems: Achieving required safety level with practical architecture
  • Safety Systems: Managing nuisance trips while maintaining safety
  • Neglecting to validate Emergency stop buttons (Category 0 or 1 stop) leads to control errors
  • Insufficient comments make Sequential Function Charts (SFC) programs unmaintainable over time

Related Certifications

🏆Siemens Certified Programmer
🏆TIA Portal Certification

Applying Sequential Function Charts (SFC) to Safety Systems using Siemens TIA Portal requires understanding the platform, the process, and the project's acceptance criteria. This guide has covered implementation structure, an illustrative code example, verification practices, and common pitfalls for a advanced Safety Systems exercise.

Use the practices outlined here to create a design that can be reviewed and tested. Define performance targets in the project requirements and confirm them with repeatable measurements.

Next Steps:

1. Check Sources: Read the current TIA Portal help, controller manual, release notes, and relevant standards
2. Practice Safely: Adapt the example in a simulator or isolated training setup
3. Review: Have the I/O map, state behavior, faults, and recovery steps reviewed
4. Test: Record normal, boundary, fault, restart, and communications test results

Sequential Function Charts (SFC) Foundation:

Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by tran...

Project duration depends on scope, reviews, hardware availability, software and firmware versions, testing, commissioning, and site constraints. Remember: Keep safety logic simple and auditable

For further learning, explore related topics including Assembly sequences, Emergency stop systems, and Siemens platform-specific features for Safety Systems optimization.