Intermediate15 min readWater & Wastewater

Mitsubishi Sequential Function Charts (SFC) for Pump Control

Learn Sequential Function Charts (SFC) programming for Pump Control using Mitsubishi GX Works2/GX Works3. Includes code examples, best practices, and step-by-step implementation guide for Water & Wastewater applications.

💻
Platform
GX Works2/GX Works3
📊
Complexity
Intermediate
⏱️
Project Duration
2-4 weeks
Optimizing Sequential Function Charts (SFC) performance for Pump Control applications in Mitsubishi's GX Works2/GX Works3 requires understanding both the platform's capabilities and the specific demands of Water & Wastewater. This guide focuses on proven optimization techniques that deliver measurable improvements in cycle time, reliability, and system responsiveness. Mitsubishi's GX Works2/GX Works3 offers powerful tools for Sequential Function Charts (SFC) programming, particularly when targeting intermediate applications like Pump Control. With 15% market share and extensive deployment in Popular in electronics manufacturing, packaging, and assembly, Mitsubishi has refined its platform based on real-world performance requirements from thousands of installations. Performance considerations for Pump Control systems extend beyond basic functionality. Critical factors include 5 sensor types requiring fast scan times, 5 actuators demanding precise timing, and the need to handle pressure regulation. The Sequential Function Charts (SFC) approach addresses these requirements through perfect for sequential processes, enabling scan times that meet even demanding Water & Wastewater applications. This guide dives deep into optimization strategies including memory management, execution order optimization, Sequential Function Charts (SFC)-specific performance tuning, and Mitsubishi-specific features that accelerate Pump Control applications. You'll learn techniques used by experienced Mitsubishi programmers to achieve maximum performance while maintaining code clarity and maintainability.

Mitsubishi GX Works2/GX Works3 for Pump Control

GX Works3 represents Mitsubishi's latest engineering software supporting the MELSEC iQ-R and iQ-F series controllers, while GX Works2 remains in use for legacy Q, L, and FX5 series PLCs. The programming environment features a project-based structure organizing programs into multiple POUs (Program Organization Units) including main programs, function blocks, and structured projects. Unlike Western PLC manufacturers, Mitsubishi supports both device-addressed programming (X0, Y0, M0, D0) and label-...

Platform Strengths for Pump Control:

  • Excellent price-to-performance ratio

  • Fast processing speeds

  • Compact form factors

  • Strong support in Asia-Pacific


Unique ${brand.software} Features:

  • Simple Motion module integration with motion SFC (Sequential Function Chart) programming eliminating complex positioning code

  • RD.DPR instruction providing direct device programming without software transfer for recipe adjustments

  • Melsoft Navigator project management integrating multiple controllers, HMIs, and network devices in unified environment

  • Multiple CPU configuration allowing up to 4 CPUs in single rack sharing memory via high-speed backplane


Key Capabilities:

The GX Works2/GX Works3 environment excels at Pump Control applications through its excellent price-to-performance ratio. This is particularly valuable when working with the 5 sensor types typically found in Pump Control systems, including Pressure transmitters, Flow meters, Level sensors.

Control Equipment for Pump Control:

  • Centrifugal pumps for high flow applications

  • Positive displacement pumps for metering

  • Submersible pumps for wet well applications

  • Booster pump systems for pressure maintenance


Mitsubishi's controller families for Pump Control include:

  • FX5: Suitable for intermediate Pump Control applications

  • iQ-R: Suitable for intermediate Pump Control applications

  • iQ-F: Suitable for intermediate Pump Control applications

  • Q Series: Suitable for intermediate Pump Control applications

Hardware Selection Guidance:

Mitsubishi offers several controller families addressing different performance and application requirements. The MELSEC iQ-R series represents the flagship product line with processing speeds as fast as 0.98ns per basic instruction supporting applications from small machines to complex automated systems. R04CPU provides 40K steps program capacity and 256K words data memory suitable for compact mac...

Industry Recognition:

High - Popular in electronics manufacturing, packaging, and assembly. Mitsubishi PLCs serve Japanese and Asian automotive manufacturers with MELSEC iQ-R controllers managing assembly line transfers, welding automation, and quality inspection systems. Body assembly lines use multiple CPU configurations (up to 4 CPUs in single rack) distributing control: CPU1 handles co...

Investment Considerations:

With $$ pricing, Mitsubishi positions itself in the mid-range segment. For Pump Control projects requiring intermediate skill levels and 2-4 weeks development time, the total investment includes hardware, software licensing, training, and ongoing support.

Understanding Sequential Function Charts (SFC) for Pump Control

Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by transitions, ideal for batch processes and machine sequences.

Execution Model:

Only active steps execute their actions. Transitions define conditions for moving between steps. Multiple steps can be active simultaneously in parallel branches.

Core Advantages for Pump Control:

  • Perfect for sequential processes: Critical for Pump Control when handling intermediate control logic

  • Clear visualization of process flow: Critical for Pump Control when handling intermediate control logic

  • Easy to understand process steps: Critical for Pump Control when handling intermediate control logic

  • Good for batch operations: Critical for Pump Control when handling intermediate control logic

  • Simplifies complex sequences: Critical for Pump Control when handling intermediate control logic


Why Sequential Function Charts (SFC) Fits Pump Control:

Pump Control systems in Water & Wastewater typically involve:

  • Sensors: Pressure transmitters for discharge and suction pressure, Flow meters (magnetic, ultrasonic, or vortex), Level transmitters for tank or wet well level

  • Actuators: Variable frequency drives (VFDs) for speed control, Motor starters (DOL or soft start), Control valves for flow regulation

  • Complexity: Intermediate with challenges including Preventing cavitation at low suction pressure


Control Strategies for Pump Control:

  • constant: Maintain fixed speed or output

  • pressure: PID control to maintain discharge pressure setpoint

  • flow: PID control to maintain flow rate setpoint


Programming Fundamentals in Sequential Function Charts (SFC):

Steps:
- initialStep: Double-bordered box - starting point of sequence, active on program start
- normalStep: Single-bordered box - becomes active when preceding transition fires
- actions: Associated code that executes while step is active

Transitions:
- condition: Boolean expression that must be TRUE to advance
- firing: Transition fires when preceding step is active AND condition is TRUE
- priority: In selective branches, transitions are evaluated in defined order

ActionQualifiers:
- N: Non-stored - executes while step is active
- S: Set - sets output TRUE on step entry, remains TRUE
- R: Reset - sets output FALSE on step entry

Best Practices for Sequential Function Charts (SFC):

  • Start with a clear process flow diagram before implementing SFC

  • Use descriptive step names indicating what happens (e.g., Filling, Heating)

  • Keep transition conditions simple - complex logic goes in action code

  • Implement timeout transitions to prevent stuck sequences

  • Always provide a path back to initial step for reset/restart


Common Mistakes to Avoid:

  • Forgetting to include stop/abort transitions for emergency handling

  • Creating deadlocks where no transition can fire

  • Not handling the case where transition conditions never become TRUE

  • Using S (Set) actions without corresponding R (Reset) actions


Typical Applications:

1. Bottle filling: Directly applicable to Pump Control
2. Assembly sequences: Related control patterns
3. Material handling: Related control patterns
4. Batch mixing: Related control patterns

Understanding these fundamentals prepares you to implement effective Sequential Function Charts (SFC) solutions for Pump Control using Mitsubishi GX Works2/GX Works3.

Implementing Pump Control with Sequential Function Charts (SFC)

Pump control systems use PLCs to regulate liquid flow in industrial processes, water treatment, and building services. These systems manage pump operation, protect equipment, optimize energy use, and maintain process parameters.

This walkthrough demonstrates practical implementation using Mitsubishi GX Works2/GX Works3 and Sequential Function Charts (SFC) programming.

System Requirements:

A typical Pump Control implementation includes:

Input Devices (Sensors):
1. Pressure transmitters for discharge and suction pressure: Critical for monitoring system state
2. Flow meters (magnetic, ultrasonic, or vortex): Critical for monitoring system state
3. Level transmitters for tank or wet well level: Critical for monitoring system state
4. Temperature sensors for bearing and motor monitoring: Critical for monitoring system state
5. Vibration sensors for predictive maintenance: Critical for monitoring system state

Output Devices (Actuators):
1. Variable frequency drives (VFDs) for speed control: Primary control output
2. Motor starters (DOL or soft start): Supporting control function
3. Control valves for flow regulation: Supporting control function
4. Isolation valves (actuated for remote operation): Supporting control function
5. Check valves to prevent backflow: Supporting control function

Control Equipment:

  • Centrifugal pumps for high flow applications

  • Positive displacement pumps for metering

  • Submersible pumps for wet well applications

  • Booster pump systems for pressure maintenance


Control Strategies for Pump Control:

  • constant: Maintain fixed speed or output

  • pressure: PID control to maintain discharge pressure setpoint

  • flow: PID control to maintain flow rate setpoint

  • level: Control tank/wet well level within band


Implementation Steps:

Step 1: Characterize pump curve and system curve

In GX Works2/GX Works3, characterize pump curve and system curve.

Step 2: Size VFD for application (constant torque vs. variable torque)

In GX Works2/GX Works3, size vfd for application (constant torque vs. variable torque).

Step 3: Implement primary control loop (pressure, flow, or level)

In GX Works2/GX Works3, implement primary control loop (pressure, flow, or level).

Step 4: Add pump protection logic (minimum flow, temperature, seal)

In GX Works2/GX Works3, add pump protection logic (minimum flow, temperature, seal).

Step 5: Program lead/lag sequencing with alternation

In GX Works2/GX Works3, program lead/lag sequencing with alternation.

Step 6: Implement soft start/stop ramps for smooth operation

In GX Works2/GX Works3, implement soft start/stop ramps for smooth operation.


Mitsubishi Function Design:

Function block (FB) programming in Mitsubishi creates reusable logic modules with defined interfaces encapsulating complexity. FB definition includes input variables (VAR_INPUT), output variables (VAR_OUTPUT), internal variables (VAR), and retained variables (VAR_RETAIN) maintaining values between calls. Creating motor control FB: inputs include Start_Cmd (BOOL), Stop_Cmd (BOOL), Speed_SP (INT), outputs include Running_Sts (BOOL), Fault_Sts (BOOL), Actual_Speed (INT), internal variables store timers, state machine stages, and diagnostic counters. FB instantiation creates instance: Motor1 (Motor_FB) with unique variable storage, allowing multiple instances Motor1, Motor2, Motor3 controlling different motors using same logic. Array of FB instances: Motors : ARRAY[1..10] OF Motor_FB accessed as Motors[3].Running_Sts checking status of motor 3. Standard function (FUN) differs from FB by lacking internal memory, suitable for calculations or conversions: Temp_Conversion_FUN(Celsius) returns Fahrenheit without retaining historical data. Structured text programming within FBs/FUNs provides clearer logic for complex algorithms compared to ladder: IF-THEN-ELSIF-ELSE structures, FOR loops, CASE statements expressing intent more directly than ladder equivalents. EN/ENO functionality enables conditional execution: EN (enable input) controls whether FB executes, ENO (enable output) indicates successful execution detecting errors within block. Library management exports FBs to library files (.glib) shared across projects and engineering teams, versioned to track modifications and ensure consistency. The intelligent function module (IFM) templates provide pre-built FBs for common applications: PID control, analog scaling, motion positioning reducing development time and providing tested reliable code. Simulation mode tests FB logic without hardware, allowing desktop development and unit testing before commissioning. Protection functionality encrypts FB contents preventing unauthorized viewing or modification, useful for proprietary algorithms or OEM machine builders distributing programs to end users.

Common Challenges and Solutions:

1. Preventing cavitation at low suction pressure

  • Solution: Sequential Function Charts (SFC) addresses this through Perfect for sequential processes.


2. Managing minimum flow requirements

  • Solution: Sequential Function Charts (SFC) addresses this through Clear visualization of process flow.


3. Coordinating VFD speed with system pressure

  • Solution: Sequential Function Charts (SFC) addresses this through Easy to understand process steps.


4. Handling pump cycling with varying demand

  • Solution: Sequential Function Charts (SFC) addresses this through Good for batch operations.


Safety Considerations:

  • Dry run protection using flow or level monitoring

  • Overtemperature protection for motor and bearings

  • Overload protection through current monitoring

  • Vibration trips for mechanical failure detection

  • Emergency stop with proper system depressurization


Performance Metrics:

  • Scan Time: Optimize for 5 inputs and 5 outputs

  • Memory Usage: Efficient data structures for FX5 capabilities

  • Response Time: Meeting Water & Wastewater requirements for Pump Control

Mitsubishi Diagnostic Tools:

Device memory monitor: Real-time table displaying current values for X, Y, M, D devices with force capability,Entry data monitor: Shows actual rung logic states with contact ON/OFF indication during program execution,Device test: Manually control outputs and set internal relays for wiring verification without program influence,Intelligent module diagnostics: Buffer memory display showing module status, error codes, and configuration,Scan time monitor: Displays current, maximum, and minimum scan times identifying performance issues,Error code history: Chronological log of system errors, module faults, and CPU events with timestamps,CC-Link/network diagnostics: Visual network status showing connected stations, errors, and communication statistics,SD card operation log: Records all SD card read/write operations, file transfers, and access timestamps,Remote diagnosis via Ethernet: Connect GX Works over network for monitoring and troubleshooting without local access,Sampling trace: Records device value changes over time with trigger conditions for intermittent fault analysis,System monitor: Displays CPU load, memory usage, and battery status for predictive maintenance,Safety diagnosis (safety CPU): Dedicated diagnostics for safety I/O discrepancy detection and emergency stop chain status

Mitsubishi's GX Works2/GX Works3 provides tools for performance monitoring and optimization, essential for achieving the 2-4 weeks development timeline while maintaining code quality.

Mitsubishi Sequential Function Charts (SFC) Example for Pump Control

Complete working example demonstrating Sequential Function Charts (SFC) implementation for Pump Control using Mitsubishi GX Works2/GX Works3. Follows Mitsubishi naming conventions. Tested on FX5 hardware.

// Mitsubishi GX Works2/GX Works3 - Pump Control Control
// Sequential Function Charts (SFC) Implementation for Water & Wastewater
// Mitsubishi programming supports both traditional device addr

// ============================================
// Variable Declarations
// ============================================
VAR
    bEnable : BOOL := FALSE;
    bEmergencyStop : BOOL := FALSE;
    rPressuretransmitters : REAL;
    rCentrifugalpumps : REAL;
END_VAR

// ============================================
// Input Conditioning - Pressure transmitters for discharge and suction pressure
// ============================================
// Standard input processing
IF rPressuretransmitters > 0.0 THEN
    bEnable := TRUE;
END_IF;

// ============================================
// Safety Interlock - Dry run protection using flow or level monitoring
// ============================================
IF bEmergencyStop THEN
    rCentrifugalpumps := 0.0;
    bEnable := FALSE;
END_IF;

// ============================================
// Main Pump Control Control Logic
// ============================================
IF bEnable AND NOT bEmergencyStop THEN
    // Pump control systems use PLCs to regulate liquid flow in ind
    rCentrifugalpumps := rPressuretransmitters * 1.0;

    // Process monitoring
    // Add specific control logic here
ELSE
    rCentrifugalpumps := 0.0;
END_IF;

Code Explanation:

  • 1.Sequential Function Charts (SFC) structure optimized for Pump Control in Water & Wastewater applications
  • 2.Input conditioning handles Pressure transmitters for discharge and suction pressure signals
  • 3.Safety interlock ensures Dry run protection using flow or level monitoring always takes priority
  • 4.Main control implements Pump control systems use PLCs to regulat
  • 5.Code runs every scan cycle on FX5 (typically 5-20ms)

Best Practices

  • Follow Mitsubishi naming conventions: Mitsubishi programming supports both traditional device addressing (M0, D100, X1
  • Mitsubishi function design: Function block (FB) programming in Mitsubishi creates reusable logic modules wit
  • Data organization: Mitsubishi uses file registers (R devices) and structured data in function block
  • Sequential Function Charts (SFC): Start with a clear process flow diagram before implementing SFC
  • Sequential Function Charts (SFC): Use descriptive step names indicating what happens (e.g., Filling, Heating)
  • Sequential Function Charts (SFC): Keep transition conditions simple - complex logic goes in action code
  • Pump Control: Use PID with derivative on PV for pressure control
  • Pump Control: Implement soft start ramps even with VFD (200-500ms)
  • Pump Control: Add flow proving before considering pump operational
  • Debug with GX Works2/GX Works3: Use sampling trace to capture high-speed events occurring faster than
  • Safety: Dry run protection using flow or level monitoring
  • Use GX Works2/GX Works3 simulation tools to test Pump Control logic before deployment

Common Pitfalls to Avoid

  • Sequential Function Charts (SFC): Forgetting to include stop/abort transitions for emergency handling
  • Sequential Function Charts (SFC): Creating deadlocks where no transition can fire
  • Sequential Function Charts (SFC): Not handling the case where transition conditions never become TRUE
  • Mitsubishi common error: Error 2110: Illegal device specified - accessing device outside configured range
  • Pump Control: Preventing cavitation at low suction pressure
  • Pump Control: Managing minimum flow requirements
  • Neglecting to validate Pressure transmitters for discharge and suction pressure leads to control errors
  • Insufficient comments make Sequential Function Charts (SFC) programs unmaintainable over time

Related Certifications

🏆Mitsubishi PLC Programming Certification
Mastering Sequential Function Charts (SFC) for Pump Control applications using Mitsubishi GX Works2/GX Works3 requires understanding both the platform's capabilities and the specific demands of Water & Wastewater. This guide has provided comprehensive coverage of implementation strategies, working code examples, best practices, and common pitfalls to help you succeed with intermediate Pump Control projects. Mitsubishi's 15% market share and high - popular in electronics manufacturing, packaging, and assembly demonstrate the platform's capability for demanding applications. The platform excels in Water & Wastewater applications where Pump Control reliability is critical. By following the practices outlined in this guide—from proper program structure and Sequential Function Charts (SFC) best practices to Mitsubishi-specific optimizations—you can deliver reliable Pump Control systems that meet Water & Wastewater requirements. **Next Steps for Professional Development:** 1. **Certification**: Pursue Mitsubishi PLC Programming Certification to validate your Mitsubishi expertise 3. **Hands-on Practice**: Build Pump Control projects using FX5 hardware 4. **Stay Current**: Follow GX Works2/GX Works3 updates and new Sequential Function Charts (SFC) features **Sequential Function Charts (SFC) Foundation:** Sequential Function Chart (SFC) is a graphical language for programming sequential processes. It models systems as a series of steps connected by tran... The 2-4 weeks typical timeline for Pump Control projects will decrease as you gain experience with these patterns and techniques. Remember: Use PID with derivative on PV for pressure control For further learning, explore related topics including Assembly sequences, Wastewater treatment, and Mitsubishi platform-specific features for Pump Control optimization.