Intermediate15 min readWater & Wastewater

Siemens Data Types for Pump Control

Learn Data Types programming for Pump Control using Siemens TIA Portal. Includes code examples, best practices, and step-by-step implementation guide for Water & Wastewater applications.

💻
Platform
TIA Portal
📊
Complexity
Intermediate
⏱️
Project Duration
2-4 weeks
Mastering advanced Data Types techniques for Pump Control in Siemens's TIA Portal unlocks capabilities beyond basic implementations. This guide explores sophisticated programming patterns, optimization strategies, and advanced features that separate expert Siemens programmers from intermediate practitioners in Water & Wastewater applications. Siemens's TIA Portal contains powerful advanced features that many programmers never fully utilize. With 28% market share and deployment in demanding applications like municipal water systems and wastewater treatment, Siemens has developed advanced capabilities specifically for intermediate projects requiring memory optimization and type safety. Advanced Pump Control implementations leverage sophisticated techniques including multi-sensor fusion algorithms, coordinated multi-actuator control, and intelligent handling of pressure regulation. When implemented using Data Types, these capabilities are achieved through data organization patterns that exploit Siemens-specific optimizations. This guide reveals advanced programming techniques used by expert Siemens programmers, including custom function blocks, optimized data structures, advanced Data Types patterns, and TIA Portal-specific features that deliver superior performance. You'll learn implementation strategies that go beyond standard documentation, based on years of practical experience with Pump Control systems in production Water & Wastewater environments.

Siemens TIA Portal for Pump Control

TIA Portal (Totally Integrated Automation Portal) represents Siemens' unified engineering framework that integrates all automation tasks in a single environment. Introduced in 2010, TIA Portal V17 and newer versions provide comprehensive tools for PLC programming, HMI development, motion control, and network configuration. The environment features a project-centric approach where all hardware components, software blocks, and visualization screens are managed within a single .ap17 project file. T...

Platform Strengths for Pump Control:

  • Excellent scalability from LOGO! to S7-1500

  • Powerful TIA Portal software environment

  • Strong global support network

  • Industry 4.0 integration capabilities


Unique ${brand.software} Features:

  • ProDiag continuous function chart for advanced diagnostics with operator-friendly error messages

  • Multi-instance data blocks allowing efficient memory use for recurring function blocks

  • Completely cross-referenced tag tables showing all uses of variables throughout the project

  • Integrated energy management functions for tracking power consumption per machine segment


Key Capabilities:

The TIA Portal environment excels at Pump Control applications through its excellent scalability from logo! to s7-1500. This is particularly valuable when working with the 5 sensor types typically found in Pump Control systems, including Pressure transmitters, Flow meters, Level sensors.

Control Equipment for Pump Control:

  • Centrifugal pumps for high flow applications

  • Positive displacement pumps for metering

  • Submersible pumps for wet well applications

  • Booster pump systems for pressure maintenance


Siemens's controller families for Pump Control include:

  • S7-1200: Suitable for intermediate Pump Control applications

  • S7-1500: Suitable for intermediate Pump Control applications

  • S7-300: Suitable for intermediate Pump Control applications

  • S7-400: Suitable for intermediate Pump Control applications

Hardware Selection Guidance:

Selecting between S7-1200 and S7-1500 families depends on performance requirements, I/O count, and future expansion needs. S7-1200 CPUs (1211C, 1212C, 1214C, 1215C, 1217C) offer 50KB to 150KB work memory with cycle times around 0.08ms per 1000 instructions, suitable for small to medium machines with up to 200 I/O points. These compact controllers support a maximum of 8 communication modules and 3 ...

Industry Recognition:

Very High - Dominant in automotive, pharmaceuticals, and food processing. Siemens S7-1500 controllers dominate automotive manufacturing with applications in body-in-white welding lines using distributed ET 200SP I/O modules connected via PROFINET for sub-millisecond response times. Engine assembly lines utilize motion control FBs for synchronized multi-axis positioning of...

Investment Considerations:

With $$$ pricing, Siemens positions itself in the premium segment. For Pump Control projects requiring intermediate skill levels and 2-4 weeks development time, the total investment includes hardware, software licensing, training, and ongoing support.

Understanding Data Types for Pump Control

PLC data types define how values are stored, their valid ranges, and operations that can be performed. Proper type selection ensures accuracy and memory efficiency.

Execution Model:

For Pump Control applications, Data Types offers significant advantages when all programming applications - choosing correct data types is fundamental to efficient plc programming.

Core Advantages for Pump Control:

  • Memory optimization: Critical for Pump Control when handling intermediate control logic

  • Type safety: Critical for Pump Control when handling intermediate control logic

  • Better organization: Critical for Pump Control when handling intermediate control logic

  • Improved performance: Critical for Pump Control when handling intermediate control logic

  • Enhanced maintainability: Critical for Pump Control when handling intermediate control logic


Why Data Types Fits Pump Control:

Pump Control systems in Water & Wastewater typically involve:

  • Sensors: Pressure transmitters for discharge and suction pressure, Flow meters (magnetic, ultrasonic, or vortex), Level transmitters for tank or wet well level

  • Actuators: Variable frequency drives (VFDs) for speed control, Motor starters (DOL or soft start), Control valves for flow regulation

  • Complexity: Intermediate with challenges including Preventing cavitation at low suction pressure


Control Strategies for Pump Control:

  • constant: Maintain fixed speed or output

  • pressure: PID control to maintain discharge pressure setpoint

  • flow: PID control to maintain flow rate setpoint


Programming Fundamentals in Data Types:

Data Types in TIA Portal follows these key principles:

1. Structure: Data Types organizes code with type safety
2. Execution: Scan cycle integration ensures 5 sensor inputs are processed reliably
3. Data Handling: Proper data types for 5 actuator control signals

Best Practices for Data Types:

  • Use smallest data type that accommodates the value range

  • Use REAL for analog values that need decimal precision

  • Create UDTs for frequently repeated data patterns

  • Use meaningful names for array indices via constants

  • Document units in comments (e.g., // Temperature in tenths of degrees)


Common Mistakes to Avoid:

  • Using INT for values that exceed 32767

  • Losing precision when converting REAL to INT

  • Array index out of bounds causing memory corruption

  • Not handling negative numbers correctly with unsigned types


Typical Applications:

1. Recipe management: Directly applicable to Pump Control
2. Data logging: Related control patterns
3. Complex calculations: Related control patterns
4. System configuration: Related control patterns

Understanding these fundamentals prepares you to implement effective Data Types solutions for Pump Control using Siemens TIA Portal.

Implementing Pump Control with Data Types

Pump control systems use PLCs to regulate liquid flow in industrial processes, water treatment, and building services. These systems manage pump operation, protect equipment, optimize energy use, and maintain process parameters.

This walkthrough demonstrates practical implementation using Siemens TIA Portal and Data Types programming.

System Requirements:

A typical Pump Control implementation includes:

Input Devices (Sensors):
1. Pressure transmitters for discharge and suction pressure: Critical for monitoring system state
2. Flow meters (magnetic, ultrasonic, or vortex): Critical for monitoring system state
3. Level transmitters for tank or wet well level: Critical for monitoring system state
4. Temperature sensors for bearing and motor monitoring: Critical for monitoring system state
5. Vibration sensors for predictive maintenance: Critical for monitoring system state

Output Devices (Actuators):
1. Variable frequency drives (VFDs) for speed control: Primary control output
2. Motor starters (DOL or soft start): Supporting control function
3. Control valves for flow regulation: Supporting control function
4. Isolation valves (actuated for remote operation): Supporting control function
5. Check valves to prevent backflow: Supporting control function

Control Equipment:

  • Centrifugal pumps for high flow applications

  • Positive displacement pumps for metering

  • Submersible pumps for wet well applications

  • Booster pump systems for pressure maintenance


Control Strategies for Pump Control:

  • constant: Maintain fixed speed or output

  • pressure: PID control to maintain discharge pressure setpoint

  • flow: PID control to maintain flow rate setpoint

  • level: Control tank/wet well level within band


Implementation Steps:

Step 1: Characterize pump curve and system curve

In TIA Portal, characterize pump curve and system curve.

Step 2: Size VFD for application (constant torque vs. variable torque)

In TIA Portal, size vfd for application (constant torque vs. variable torque).

Step 3: Implement primary control loop (pressure, flow, or level)

In TIA Portal, implement primary control loop (pressure, flow, or level).

Step 4: Add pump protection logic (minimum flow, temperature, seal)

In TIA Portal, add pump protection logic (minimum flow, temperature, seal).

Step 5: Program lead/lag sequencing with alternation

In TIA Portal, program lead/lag sequencing with alternation.

Step 6: Implement soft start/stop ramps for smooth operation

In TIA Portal, implement soft start/stop ramps for smooth operation.


Siemens Function Design:

Functions (FCs) and Function Blocks (FBs) form the modular building blocks of structured Siemens programs. FCs are stateless code blocks without persistent memory, suitable for calculations, data conversions, or operations that don't require retaining values between calls. FC parameters include IN for input values, OUT for returned results, IN_OUT for passed pointers to existing variables, and TEMP for temporary calculations discarded after execution. Return values are defined using the RETURN data type declaration. FBs contain STAT (static) variables that persist between scan cycles, stored in instance DBs, making them ideal for controlling equipment with ongoing state like motors, valves, or process loops. Multi-instance FBs reduce memory overhead by embedding multiple FB instances within a parent FB's instance DB. The block interface clearly separates Input, Output, InOut, Stat (persistent), Temp (temporary), and Constant sections. FB parameters should include Enable inputs, feedback status outputs, error outputs with diagnostic codes, and configuration parameters for setpoints and timings. Versioned FBs in Type Libraries support interface extensions while maintaining backward compatibility using optional parameters with default values. Generic FB designs incorporate enumerated data types (ENUM) for state machines: WAITING, RUNNING, STOPPING, FAULTED. Call structures pass instance DB references explicitly: Motor_FB(DB1) or multi-instances as Motor_FB.Instance[1]. SCL (Structured Control Language) provides text-based programming within FCs/FBs for complex algorithms, offering better readability than ladder for mathematical operations and CASE statements. Block properties define code attributes: Know-how protection encrypts proprietary logic, version information tracks revisions, and block icons customize graphic representation in calling networks.

Common Challenges and Solutions:

1. Preventing cavitation at low suction pressure

  • Solution: Data Types addresses this through Memory optimization.


2. Managing minimum flow requirements

  • Solution: Data Types addresses this through Type safety.


3. Coordinating VFD speed with system pressure

  • Solution: Data Types addresses this through Better organization.


4. Handling pump cycling with varying demand

  • Solution: Data Types addresses this through Improved performance.


Safety Considerations:

  • Dry run protection using flow or level monitoring

  • Overtemperature protection for motor and bearings

  • Overload protection through current monitoring

  • Vibration trips for mechanical failure detection

  • Emergency stop with proper system depressurization


Performance Metrics:

  • Scan Time: Optimize for 5 inputs and 5 outputs

  • Memory Usage: Efficient data structures for S7-1200 capabilities

  • Response Time: Meeting Water & Wastewater requirements for Pump Control

Siemens Diagnostic Tools:

Program Status: Real-time monitoring showing actual rung logic states with green highlights for TRUE conditions and value displays,Force Tables: Override inputs/outputs permanently (use with extreme caution, indicated by warning icons),Modify Variable: Temporarily change tag values in online mode for testing without redownload,Trace & Watch Tables: Record up to 50 variables synchronously with 1ms resolution, triggered by conditions,Diagnostic Buffer: Chronological log of 200 system events including mode changes, errors, and module diagnostics,ProDiag Viewer: Displays user-configured diagnostic messages with operator guidance and troubleshooting steps,Web Server Diagnostics: Browser-based access to buffer, topology, communication load, and module status,PROFINET Topology: Live view of network with link quality, update times, and neighbor relationships,Memory Usage Statistics: Real-time display of work memory, load memory, and retentive memory consumption,Communication Diagnostics: Connection statistics, telegram counters, and partner unreachable conditions,Test & Commissioning Functions: Actuator testing, sensor simulation, and step-by-step execution modes,Reference Data Cross-Reference: Shows all code locations using specific variables, DBs, or I/O addresses

Siemens's TIA Portal provides tools for performance monitoring and optimization, essential for achieving the 2-4 weeks development timeline while maintaining code quality.

Siemens Data Types Example for Pump Control

Complete working example demonstrating Data Types implementation for Pump Control using Siemens TIA Portal. Follows Siemens naming conventions. Tested on S7-1200 hardware.

// Siemens TIA Portal - Pump Control Control
// Data Types Implementation for Water & Wastewater
// Siemens recommends structured naming conventions using the P

// ============================================
// Variable Declarations
// ============================================
VAR
    bEnable : BOOL := FALSE;
    bEmergencyStop : BOOL := FALSE;
    rPressuretransmitters : REAL;
    rCentrifugalpumps : REAL;
END_VAR

// ============================================
// Input Conditioning - Pressure transmitters for discharge and suction pressure
// ============================================
// Standard input processing
IF rPressuretransmitters > 0.0 THEN
    bEnable := TRUE;
END_IF;

// ============================================
// Safety Interlock - Dry run protection using flow or level monitoring
// ============================================
IF bEmergencyStop THEN
    rCentrifugalpumps := 0.0;
    bEnable := FALSE;
END_IF;

// ============================================
// Main Pump Control Control Logic
// ============================================
IF bEnable AND NOT bEmergencyStop THEN
    // Pump control systems use PLCs to regulate liquid flow in ind
    rCentrifugalpumps := rPressuretransmitters * 1.0;

    // Process monitoring
    // Add specific control logic here
ELSE
    rCentrifugalpumps := 0.0;
END_IF;

Code Explanation:

  • 1.Data Types structure optimized for Pump Control in Water & Wastewater applications
  • 2.Input conditioning handles Pressure transmitters for discharge and suction pressure signals
  • 3.Safety interlock ensures Dry run protection using flow or level monitoring always takes priority
  • 4.Main control implements Pump control systems use PLCs to regulat
  • 5.Code runs every scan cycle on S7-1200 (typically 5-20ms)

Best Practices

  • Follow Siemens naming conventions: Siemens recommends structured naming conventions using the PLC tag table with sy
  • Siemens function design: Functions (FCs) and Function Blocks (FBs) form the modular building blocks of st
  • Data organization: Data Blocks (DBs) are fundamental to Siemens programming, serving as structured
  • Data Types: Use smallest data type that accommodates the value range
  • Data Types: Use REAL for analog values that need decimal precision
  • Data Types: Create UDTs for frequently repeated data patterns
  • Pump Control: Use PID with derivative on PV for pressure control
  • Pump Control: Implement soft start ramps even with VFD (200-500ms)
  • Pump Control: Add flow proving before considering pump operational
  • Debug with TIA Portal: Use CALL_TRACE to identify the call hierarchy leading to errors in dee
  • Safety: Dry run protection using flow or level monitoring
  • Use TIA Portal simulation tools to test Pump Control logic before deployment

Common Pitfalls to Avoid

  • Data Types: Using INT for values that exceed 32767
  • Data Types: Losing precision when converting REAL to INT
  • Data Types: Array index out of bounds causing memory corruption
  • Siemens common error: 16#8022: DB does not exist or is too short - called DB number not loaded or inte
  • Pump Control: Preventing cavitation at low suction pressure
  • Pump Control: Managing minimum flow requirements
  • Neglecting to validate Pressure transmitters for discharge and suction pressure leads to control errors
  • Insufficient comments make Data Types programs unmaintainable over time

Related Certifications

🏆Siemens Certified Programmer
🏆TIA Portal Certification
Mastering Data Types for Pump Control applications using Siemens TIA Portal requires understanding both the platform's capabilities and the specific demands of Water & Wastewater. This guide has provided comprehensive coverage of implementation strategies, working code examples, best practices, and common pitfalls to help you succeed with intermediate Pump Control projects. Siemens's 28% market share and very high - dominant in automotive, pharmaceuticals, and food processing demonstrate the platform's capability for demanding applications. The platform excels in Water & Wastewater applications where Pump Control reliability is critical. By following the practices outlined in this guide—from proper program structure and Data Types best practices to Siemens-specific optimizations—you can deliver reliable Pump Control systems that meet Water & Wastewater requirements. **Next Steps for Professional Development:** 1. **Certification**: Pursue Siemens Certified Programmer to validate your Siemens expertise 2. **Advanced Training**: Consider TIA Portal Certification for specialized Water & Wastewater applications 3. **Hands-on Practice**: Build Pump Control projects using S7-1200 hardware 4. **Stay Current**: Follow TIA Portal updates and new Data Types features **Data Types Foundation:** PLC data types define how values are stored, their valid ranges, and operations that can be performed. Proper type selection ensures accuracy and memo... The 2-4 weeks typical timeline for Pump Control projects will decrease as you gain experience with these patterns and techniques. Remember: Use PID with derivative on PV for pressure control For further learning, explore related topics including Data logging, Wastewater treatment, and Siemens platform-specific features for Pump Control optimization.