Intermediate15 min readProcess Control

Schneider Electric Function Blocks for Temperature Control

Learn Function Blocks programming for Temperature Control using Schneider Electric EcoStruxure Machine Expert. Includes code examples, best practices, and step-by-step implementation guide for Process Control applications.

💻
Platform
EcoStruxure Machine Expert
📊
Complexity
Intermediate
⏱️
Project Duration
2-3 weeks
Implementing Function Blocks for Temperature Control using Schneider Electric EcoStruxure Machine Expert requires adherence to industry standards and proven best practices from Process Control. This guide compiles best practices from successful Temperature Control deployments, Schneider Electric programming standards, and Process Control requirements to help you deliver professional-grade automation solutions. Schneider Electric's position as High - Strong in food & beverage, water treatment, and building automation means their platforms must meet rigorous industry requirements. Companies like Modicon M580 users in industrial ovens and plastic molding machines have established proven patterns for Function Blocks implementation that balance functionality, maintainability, and safety. Best practices for Temperature Control encompass multiple dimensions: proper handling of 4 sensor types, safe control of 5 different actuators, managing pid tuning, and ensuring compliance with relevant industry standards. The Function Blocks approach, when properly implemented, provides visual representation of signal flow and good for modular programming, both critical for intermediate projects. This guide presents industry-validated approaches to Schneider Electric Function Blocks programming for Temperature Control, covering code organization standards, documentation requirements, testing procedures, and maintenance best practices. You'll learn how leading companies structure their Temperature Control programs, handle error conditions, and ensure long-term reliability in production environments.

Schneider Electric EcoStruxure Machine Expert for Temperature Control

EcoStruxure Machine Expert (formerly SoMachine) provides Schneider Electric's unified programming environment for Modicon M221, M241, M251, M262, and M580 PLCs. Built on the CODESYS V3 platform, Machine Expert delivers IEC 61131-3 compliant programming with all five languages plus CFC (Continuous Function Chart). The environment supports object-oriented programming extensions including classes, interfaces, methods, and properties for creating sophisticated reusable code libraries....

Platform Strengths for Temperature Control:

  • Excellent energy efficiency features

  • Strong IoT/cloud integration

  • Good balance of price and performance

  • Wide product range


Unique ${brand.software} Features:

  • CODESYS V3-based platform with full IEC 61131-3 language support plus extensions

  • Object-oriented programming with classes, methods, properties, and interfaces

  • Integrated motion control workbench for cam design and multi-axis coordination

  • Machine Expert Twin for digital twin simulation and virtual commissioning


Key Capabilities:

The EcoStruxure Machine Expert environment excels at Temperature Control applications through its excellent energy efficiency features. This is particularly valuable when working with the 4 sensor types typically found in Temperature Control systems, including Thermocouples (K-type, J-type), RTD sensors (PT100, PT1000), Infrared temperature sensors.

Control Equipment for Temperature Control:

  • Electric resistance heaters (cartridge, band, strip)

  • Steam injection systems

  • Thermal fluid (hot oil) systems

  • Refrigeration and chiller systems


Schneider Electric's controller families for Temperature Control include:

  • Modicon M580: Suitable for intermediate Temperature Control applications

  • Modicon M340: Suitable for intermediate Temperature Control applications

  • Modicon M221: Suitable for intermediate Temperature Control applications

  • Modicon M241: Suitable for intermediate Temperature Control applications

Hardware Selection Guidance:

Schneider's Modicon portfolio spans compact to high-performance controllers. M221 offers cost-effective control for simple machines. M241/M251 add performance and networking. M262 targets high-performance motion applications with Sercos III. M580 addresses process applications with hot-standby redundancy....

Industry Recognition:

High - Strong in food & beverage, water treatment, and building automation. Schneider M580/M262 controllers serve automotive with production line flexibility and energy management. Vision-guided robotics, energy monitoring via PowerLogic meters, and safety integration via Preventa controllers....

Investment Considerations:

With $$ pricing, Schneider Electric positions itself in the mid-range segment. For Temperature Control projects requiring intermediate skill levels and 2-3 weeks development time, the total investment includes hardware, software licensing, training, and ongoing support.

Understanding Function Blocks for Temperature Control

Function Block Diagram (FBD) is a graphical programming language where functions and function blocks are represented as boxes connected by signal lines. Data flows from left to right through the network.

Execution Model:

Blocks execute based on data dependencies - a block executes only when all its inputs are available. Networks execute top to bottom when dependencies allow.

Core Advantages for Temperature Control:

  • Visual representation of signal flow: Critical for Temperature Control when handling intermediate control logic

  • Good for modular programming: Critical for Temperature Control when handling intermediate control logic

  • Reusable components: Critical for Temperature Control when handling intermediate control logic

  • Excellent for process control: Critical for Temperature Control when handling intermediate control logic

  • Good for continuous operations: Critical for Temperature Control when handling intermediate control logic


Why Function Blocks Fits Temperature Control:

Temperature Control systems in Process Control typically involve:

  • Sensors: RTDs (PT100/PT1000) for high-accuracy measurements, Thermocouples (J, K, T types) for high-temperature applications, Infrared pyrometers for non-contact measurement

  • Actuators: SCR (thyristor) power controllers for electric heaters, Solid-state relays for on/off heating control, Proportional control valves for steam or thermal fluid

  • Complexity: Intermediate with challenges including Long thermal time constants making tuning difficult


Control Strategies for Temperature Control:

  • pid: Standard PID control with proportional, integral, and derivative terms tuned for the thermal process dynamics

  • cascade: Master temperature loop outputs to slave heater/cooler control loop for tighter control

  • ratio: Maintain temperature ratio between zones for gradient applications


Programming Fundamentals in Function Blocks:

StandardBlocks:
- logic: AND, OR, XOR, NOT - Boolean logic operations
- comparison: EQ, NE, LT, GT, LE, GE - Compare values
- math: ADD, SUB, MUL, DIV, MOD - Arithmetic operations

TimersCounters:
- ton: Timer On-Delay - Output turns ON after preset time
- tof: Timer Off-Delay - Output turns OFF after preset time
- tp: Pulse Timer - Output pulses for preset time

Connections:
- wires: Connect output pins to input pins to pass data
- branches: One output can connect to multiple inputs
- feedback: Outputs can feed back to inputs for state machines

Best Practices for Function Blocks:

  • Arrange blocks for clear left-to-right data flow

  • Use consistent spacing and alignment for readability

  • Label all inputs and outputs with meaningful names

  • Create custom FBs for frequently repeated logic patterns

  • Minimize wire crossings by careful block placement


Common Mistakes to Avoid:

  • Creating feedback loops without proper initialization

  • Connecting incompatible data types

  • Not considering execution order dependencies

  • Overcrowding networks making them hard to read


Typical Applications:

1. HVAC control: Directly applicable to Temperature Control
2. Temperature control: Related control patterns
3. Flow control: Related control patterns
4. Batch processing: Related control patterns

Understanding these fundamentals prepares you to implement effective Function Blocks solutions for Temperature Control using Schneider Electric EcoStruxure Machine Expert.

Implementing Temperature Control with Function Blocks

Industrial temperature control systems use PLCs to regulate process temperatures in manufacturing, food processing, chemical processing, and other applications. These systems maintain precise temperature setpoints through heating and cooling control while ensuring product quality and energy efficiency.

This walkthrough demonstrates practical implementation using Schneider Electric EcoStruxure Machine Expert and Function Blocks programming.

System Requirements:

A typical Temperature Control implementation includes:

Input Devices (Sensors):
1. RTDs (PT100/PT1000) for high-accuracy measurements: Critical for monitoring system state
2. Thermocouples (J, K, T types) for high-temperature applications: Critical for monitoring system state
3. Infrared pyrometers for non-contact measurement: Critical for monitoring system state
4. Thermistors for fast response applications: Critical for monitoring system state
5. Thermal imaging cameras for surface temperature monitoring: Critical for monitoring system state

Output Devices (Actuators):
1. SCR (thyristor) power controllers for electric heaters: Primary control output
2. Solid-state relays for on/off heating control: Supporting control function
3. Proportional control valves for steam or thermal fluid: Supporting control function
4. Solenoid valves for cooling water or refrigerant: Supporting control function
5. Variable frequency drives for cooling fan control: Supporting control function

Control Equipment:

  • Electric resistance heaters (cartridge, band, strip)

  • Steam injection systems

  • Thermal fluid (hot oil) systems

  • Refrigeration and chiller systems


Control Strategies for Temperature Control:

  • pid: Standard PID control with proportional, integral, and derivative terms tuned for the thermal process dynamics

  • cascade: Master temperature loop outputs to slave heater/cooler control loop for tighter control

  • ratio: Maintain temperature ratio between zones for gradient applications


Implementation Steps:

Step 1: Characterize thermal system dynamics (time constants, dead time)

In EcoStruxure Machine Expert, characterize thermal system dynamics (time constants, dead time).

Step 2: Select appropriate sensor type and placement for representative measurement

In EcoStruxure Machine Expert, select appropriate sensor type and placement for representative measurement.

Step 3: Size heating and cooling capacity for worst-case load conditions

In EcoStruxure Machine Expert, size heating and cooling capacity for worst-case load conditions.

Step 4: Implement PID control with appropriate sample time (typically 10x faster than process time constant)

In EcoStruxure Machine Expert, implement pid control with appropriate sample time (typically 10x faster than process time constant).

Step 5: Add output limiting and anti-windup for safe operation

In EcoStruxure Machine Expert, add output limiting and anti-windup for safe operation.

Step 6: Program ramp/soak profiles if required

In EcoStruxure Machine Expert, program ramp/soak profiles if required.


Schneider Electric Function Design:

Function blocks follow object-oriented principles with Input/Output/InOut parameters, Methods extending functionality, and Properties providing controlled access. Interfaces enable polymorphism.

Common Challenges and Solutions:

1. Long thermal time constants making tuning difficult

  • Solution: Function Blocks addresses this through Visual representation of signal flow.


2. Transport delay (dead time) causing instability

  • Solution: Function Blocks addresses this through Good for modular programming.


3. Non-linear response at different temperature ranges

  • Solution: Function Blocks addresses this through Reusable components.


4. Sensor placement affecting measurement accuracy

  • Solution: Function Blocks addresses this through Excellent for process control.


Safety Considerations:

  • Independent high-limit safety thermostats (redundant to PLC)

  • Watchdog timers for heater control validity

  • Safe-state definition on controller failure (heaters off)

  • Thermal fuse backup for runaway conditions

  • Proper ventilation for combustible atmospheres


Performance Metrics:

  • Scan Time: Optimize for 4 inputs and 5 outputs

  • Memory Usage: Efficient data structures for Modicon M580 capabilities

  • Response Time: Meeting Process Control requirements for Temperature Control

Schneider Electric Diagnostic Tools:

Online monitoring overlay showing live values,Watch window tracking variables with expressions,Breakpoints pausing execution for inspection,Trace recording variable changes over time,Device diagnostics showing module status

Schneider Electric's EcoStruxure Machine Expert provides tools for performance monitoring and optimization, essential for achieving the 2-3 weeks development timeline while maintaining code quality.

Schneider Electric Function Blocks Example for Temperature Control

Complete working example demonstrating Function Blocks implementation for Temperature Control using Schneider Electric EcoStruxure Machine Expert. Follows Schneider Electric naming conventions. Tested on Modicon M580 hardware.

(* Schneider Electric EcoStruxure Machine Expert - Temperature Control Control *)
(* Reusable Function Blocks Implementation *)
(* Function blocks follow object-oriented principles with Input *)

FUNCTION_BLOCK FB_TEMPERATURE_CONTROL_Controller

VAR_INPUT
    bEnable : BOOL;                  (* Enable control *)
    bReset : BOOL;                   (* Fault reset *)
    rProcessValue : REAL;            (* RTDs (PT100/PT1000) for high-accuracy measurements *)
    rSetpoint : REAL := 100.0;  (* Target value *)
    bEmergencyStop : BOOL;           (* Safety input *)
END_VAR

VAR_OUTPUT
    rControlOutput : REAL;           (* SCR (thyristor) power controllers for electric heaters *)
    bRunning : BOOL;                 (* Process active *)
    bComplete : BOOL;                (* Cycle complete *)
    bFault : BOOL;                   (* Fault status *)
    nFaultCode : INT;                (* Diagnostic code *)
END_VAR

VAR
    (* Internal Function Blocks *)
    fbSafety : FB_SafetyMonitor;     (* Safety logic *)
    fbRamp : FB_RampGenerator;       (* Soft start/stop *)
    fbPID : FB_PIDController;        (* Process control *)
    fbDiag : FB_Diagnostics;         (* Use ST_Alarm structure with bActive, bAcknowledged, dtActivation, nCode, sMessage. Array of alarms with detection, acknowledgment, and logging methods. *)

    (* Internal State *)
    eInternalState : E_ControlState;
    tonWatchdog : TON;
END_VAR

(* Safety Monitor - Independent high-limit safety thermostats (redundant to PLC) *)
fbSafety(
    Enable := bEnable,
    EmergencyStop := bEmergencyStop,
    ProcessValue := rProcessValue,
    HighLimit := rSetpoint * 1.2,
    LowLimit := rSetpoint * 0.1
);

(* Main Control Logic *)
IF fbSafety.SafeToRun THEN
    (* Ramp Generator - Prevents startup surge *)
    fbRamp(
        Enable := bEnable,
        TargetValue := rSetpoint,
        RampRate := 20.0,  (* Process Control rate *)
        CurrentValue => rSetpoint
    );

    (* PID Controller - [object Object] *)
    fbPID(
        Enable := fbRamp.InPosition,
        ProcessValue := rProcessValue,
        Setpoint := fbRamp.CurrentValue,
        Kp := 1.0,
        Ki := 0.1,
        Kd := 0.05,
        OutputMin := 0.0,
        OutputMax := 100.0
    );

    rControlOutput := fbPID.Output;
    bRunning := TRUE;
    bFault := FALSE;
    nFaultCode := 0;

ELSE
    (* Safe State - Watchdog timers for heater control validity *)
    rControlOutput := 0.0;
    bRunning := FALSE;
    bFault := NOT bEnable;  (* Only fault if not intentional stop *)
    nFaultCode := fbSafety.FaultCode;
END_IF;

(* Diagnostics - Circular buffer with ST_LogRecord structure. Write index increments with modulo wrap. File export using SysFile library writing CSV format. *)
fbDiag(
    ProcessRunning := bRunning,
    FaultActive := bFault,
    ProcessValue := rProcessValue,
    ControlOutput := rControlOutput
);

(* Watchdog - Detects frozen control *)
tonWatchdog(IN := bRunning AND NOT fbPID.OutputChanging, PT := T#10S);
IF tonWatchdog.Q THEN
    bFault := TRUE;
    nFaultCode := 99;  (* Watchdog fault *)
END_IF;

(* Reset Logic *)
IF bReset AND NOT bEmergencyStop THEN
    bFault := FALSE;
    nFaultCode := 0;
    fbDiag.ClearAlarms();
END_IF;

END_FUNCTION_BLOCK

Code Explanation:

  • 1.Encapsulated function block follows Function blocks follow object-oriented p - reusable across Process Control projects
  • 2.FB_SafetyMonitor provides Independent high-limit safety thermostats (redundant to PLC) including high/low limits
  • 3.FB_RampGenerator prevents startup issues common in Temperature Control systems
  • 4.FB_PIDController tuned for Process Control: Kp=1.0, Ki=0.1
  • 5.Watchdog timer detects frozen control - critical for intermediate Temperature Control reliability
  • 6.Diagnostic function block enables Circular buffer with ST_LogRecord structure. Write index increments with modulo wrap. File export using SysFile library writing CSV format. and Use ST_Alarm structure with bActive, bAcknowledged, dtActivation, nCode, sMessage. Array of alarms with detection, acknowledgment, and logging methods.

Best Practices

  • Follow Schneider Electric naming conventions: Schneider recommends Hungarian-style prefixes: g_ for globals, i_ and q_ for FB
  • Schneider Electric function design: Function blocks follow object-oriented principles with Input/Output/InOut parame
  • Data organization: Structured data uses GVLs grouping related globals and DUTs defining custom type
  • Function Blocks: Arrange blocks for clear left-to-right data flow
  • Function Blocks: Use consistent spacing and alignment for readability
  • Function Blocks: Label all inputs and outputs with meaningful names
  • Temperature Control: Sample at 1/10 of the process time constant minimum
  • Temperature Control: Use derivative on PV, not error, for temperature control
  • Temperature Control: Start with conservative tuning and tighten gradually
  • Debug with EcoStruxure Machine Expert: Use structured logging with severity levels
  • Safety: Independent high-limit safety thermostats (redundant to PLC)
  • Use EcoStruxure Machine Expert simulation tools to test Temperature Control logic before deployment

Common Pitfalls to Avoid

  • Function Blocks: Creating feedback loops without proper initialization
  • Function Blocks: Connecting incompatible data types
  • Function Blocks: Not considering execution order dependencies
  • Schneider Electric common error: Exception 'AccessViolation': Null pointer dereference
  • Temperature Control: Long thermal time constants making tuning difficult
  • Temperature Control: Transport delay (dead time) causing instability
  • Neglecting to validate RTDs (PT100/PT1000) for high-accuracy measurements leads to control errors
  • Insufficient comments make Function Blocks programs unmaintainable over time

Related Certifications

🏆EcoStruxure Certified Expert
🏆Advanced Schneider Electric Programming Certification
Mastering Function Blocks for Temperature Control applications using Schneider Electric EcoStruxure Machine Expert requires understanding both the platform's capabilities and the specific demands of Process Control. This guide has provided comprehensive coverage of implementation strategies, working code examples, best practices, and common pitfalls to help you succeed with intermediate Temperature Control projects. Schneider Electric's 12% market share and high - strong in food & beverage, water treatment, and building automation demonstrate the platform's capability for demanding applications. The platform excels in Process Control applications where Temperature Control reliability is critical. By following the practices outlined in this guide—from proper program structure and Function Blocks best practices to Schneider Electric-specific optimizations—you can deliver reliable Temperature Control systems that meet Process Control requirements. **Next Steps for Professional Development:** 1. **Certification**: Pursue EcoStruxure Certified Expert to validate your Schneider Electric expertise 3. **Hands-on Practice**: Build Temperature Control projects using Modicon M580 hardware 4. **Stay Current**: Follow EcoStruxure Machine Expert updates and new Function Blocks features **Function Blocks Foundation:** Function Block Diagram (FBD) is a graphical programming language where functions and function blocks are represented as boxes connected by signal line... The 2-3 weeks typical timeline for Temperature Control projects will decrease as you gain experience with these patterns and techniques. Remember: Sample at 1/10 of the process time constant minimum For further learning, explore related topics including Temperature control, Plastic molding machines, and Schneider Electric platform-specific features for Temperature Control optimization.