Intermediate20 min readPackaging

Mitsubishi Data Types for Packaging Automation

Learn Data Types programming for Packaging Automation using Mitsubishi GX Works2/GX Works3. Includes code examples, best practices, and step-by-step implementation guide for Packaging applications.

💻
Platform
GX Works2/GX Works3
📊
Complexity
Intermediate to Advanced
⏱️
Project Duration
3-6 weeks
Learning to implement Data Types for Packaging Automation using Mitsubishi's GX Works2/GX Works3 is an essential skill for PLC programmers working in Packaging. This comprehensive guide walks you through the fundamentals, providing clear explanations and practical examples that you can apply immediately to real-world projects. Mitsubishi has established itself as High - Popular in electronics manufacturing, packaging, and assembly, making it a strategic choice for Packaging Automation applications. With 15% global market share and 4 popular PLC families including the FX5 and iQ-R, Mitsubishi provides the robust platform needed for intermediate to advanced complexity projects like Packaging Automation. The Data Types approach is particularly well-suited for Packaging Automation because all programming applications - choosing correct data types is fundamental to efficient plc programming. This combination allows you to leverage memory optimization while managing the typical challenges of Packaging Automation, including product changeover and high-speed synchronization. Throughout this guide, you'll discover step-by-step implementation strategies, working code examples tested on GX Works2/GX Works3, and industry best practices specific to Packaging. Whether you're programming your first Packaging Automation system or transitioning from another PLC platform, this guide provides the practical knowledge you need to succeed with Mitsubishi Data Types programming.

Mitsubishi GX Works2/GX Works3 for Packaging Automation

GX Works3 represents Mitsubishi's latest engineering software supporting the MELSEC iQ-R and iQ-F series controllers, while GX Works2 remains in use for legacy Q, L, and FX5 series PLCs. The programming environment features a project-based structure organizing programs into multiple POUs (Program Organization Units) including main programs, function blocks, and structured projects. Unlike Western PLC manufacturers, Mitsubishi supports both device-addressed programming (X0, Y0, M0, D0) and label-...

Platform Strengths for Packaging Automation:

  • Excellent price-to-performance ratio

  • Fast processing speeds

  • Compact form factors

  • Strong support in Asia-Pacific


Unique ${brand.software} Features:

  • Simple Motion module integration with motion SFC (Sequential Function Chart) programming eliminating complex positioning code

  • RD.DPR instruction providing direct device programming without software transfer for recipe adjustments

  • Melsoft Navigator project management integrating multiple controllers, HMIs, and network devices in unified environment

  • Multiple CPU configuration allowing up to 4 CPUs in single rack sharing memory via high-speed backplane


Key Capabilities:

The GX Works2/GX Works3 environment excels at Packaging Automation applications through its excellent price-to-performance ratio. This is particularly valuable when working with the 5 sensor types typically found in Packaging Automation systems, including Vision systems, Weight sensors, Barcode scanners.

Control Equipment for Packaging Automation:

  • Form-fill-seal machines (horizontal and vertical)

  • Case erectors and sealers

  • Labeling systems (pressure sensitive, shrink sleeve)

  • Case packers (drop, wrap-around, robotic)


Mitsubishi's controller families for Packaging Automation include:

  • FX5: Suitable for intermediate to advanced Packaging Automation applications

  • iQ-R: Suitable for intermediate to advanced Packaging Automation applications

  • iQ-F: Suitable for intermediate to advanced Packaging Automation applications

  • Q Series: Suitable for intermediate to advanced Packaging Automation applications

Hardware Selection Guidance:

Mitsubishi offers several controller families addressing different performance and application requirements. The MELSEC iQ-R series represents the flagship product line with processing speeds as fast as 0.98ns per basic instruction supporting applications from small machines to complex automated systems. R04CPU provides 40K steps program capacity and 256K words data memory suitable for compact mac...

Industry Recognition:

High - Popular in electronics manufacturing, packaging, and assembly. Packaging machinery manufacturers across Asia Pacific standardize on Mitsubishi for flexibility, compact form factors, and responsive local technical support. Form-fill-seal machines use coordinated motion controlling film advance, product dosing, sealing, and cutting with electronic line shaft (vir...

Investment Considerations:

With $$ pricing, Mitsubishi positions itself in the mid-range segment. For Packaging Automation projects requiring advanced skill levels and 3-6 weeks development time, the total investment includes hardware, software licensing, training, and ongoing support.

Understanding Data Types for Packaging Automation

PLC data types define how values are stored, their valid ranges, and operations that can be performed. Proper type selection ensures accuracy and memory efficiency.

Execution Model:

For Packaging Automation applications, Data Types offers significant advantages when all programming applications - choosing correct data types is fundamental to efficient plc programming.

Core Advantages for Packaging Automation:

  • Memory optimization: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Type safety: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Better organization: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Improved performance: Critical for Packaging Automation when handling intermediate to advanced control logic

  • Enhanced maintainability: Critical for Packaging Automation when handling intermediate to advanced control logic


Why Data Types Fits Packaging Automation:

Packaging Automation systems in Packaging typically involve:

  • Sensors: Product detection sensors for counting and positioning, Registration sensors for label and film alignment, Barcode/2D code readers for verification

  • Actuators: Servo drives for precise motion control, Pneumatic cylinders for pick-and-place, Vacuum generators and cups

  • Complexity: Intermediate to Advanced with challenges including Maintaining registration at high speeds


Programming Fundamentals in Data Types:

Data Types in GX Works2/GX Works3 follows these key principles:

1. Structure: Data Types organizes code with type safety
2. Execution: Scan cycle integration ensures 5 sensor inputs are processed reliably
3. Data Handling: Proper data types for 5 actuator control signals

Best Practices for Data Types:

  • Use smallest data type that accommodates the value range

  • Use REAL for analog values that need decimal precision

  • Create UDTs for frequently repeated data patterns

  • Use meaningful names for array indices via constants

  • Document units in comments (e.g., // Temperature in tenths of degrees)


Common Mistakes to Avoid:

  • Using INT for values that exceed 32767

  • Losing precision when converting REAL to INT

  • Array index out of bounds causing memory corruption

  • Not handling negative numbers correctly with unsigned types


Typical Applications:

1. Recipe management: Directly applicable to Packaging Automation
2. Data logging: Related control patterns
3. Complex calculations: Related control patterns
4. System configuration: Related control patterns

Understanding these fundamentals prepares you to implement effective Data Types solutions for Packaging Automation using Mitsubishi GX Works2/GX Works3.

Implementing Packaging Automation with Data Types

Packaging automation systems use PLCs to coordinate primary, secondary, and tertiary packaging operations. These systems control filling, labeling, case packing, palletizing, and integration with production and warehouse systems.

This walkthrough demonstrates practical implementation using Mitsubishi GX Works2/GX Works3 and Data Types programming.

System Requirements:

A typical Packaging Automation implementation includes:

Input Devices (Sensors):
1. Product detection sensors for counting and positioning: Critical for monitoring system state
2. Registration sensors for label and film alignment: Critical for monitoring system state
3. Barcode/2D code readers for verification: Critical for monitoring system state
4. Vision systems for quality inspection: Critical for monitoring system state
5. Reject confirmation sensors: Critical for monitoring system state

Output Devices (Actuators):
1. Servo drives for precise motion control: Primary control output
2. Pneumatic cylinders for pick-and-place: Supporting control function
3. Vacuum generators and cups: Supporting control function
4. Glue and tape applicators: Supporting control function
5. Film tensioners and seal bars: Supporting control function

Control Equipment:

  • Form-fill-seal machines (horizontal and vertical)

  • Case erectors and sealers

  • Labeling systems (pressure sensitive, shrink sleeve)

  • Case packers (drop, wrap-around, robotic)


Control Strategies for Packaging Automation:

1. Primary Control: Automated packaging systems using PLCs for product wrapping, boxing, labeling, and palletizing.
2. Safety Interlocks: Preventing Product changeover
3. Error Recovery: Handling High-speed synchronization

Implementation Steps:

Step 1: Define packaging specifications for all product variants

In GX Works2/GX Works3, define packaging specifications for all product variants.

Step 2: Create motion profiles for each packaging format

In GX Works2/GX Works3, create motion profiles for each packaging format.

Step 3: Implement registration control with encoder feedback

In GX Works2/GX Works3, implement registration control with encoder feedback.

Step 4: Program pattern generation for case and pallet loading

In GX Works2/GX Works3, program pattern generation for case and pallet loading.

Step 5: Add reject handling with confirmation logic

In GX Works2/GX Works3, add reject handling with confirmation logic.

Step 6: Implement barcode/vision integration for verification

In GX Works2/GX Works3, implement barcode/vision integration for verification.


Mitsubishi Function Design:

Function block (FB) programming in Mitsubishi creates reusable logic modules with defined interfaces encapsulating complexity. FB definition includes input variables (VAR_INPUT), output variables (VAR_OUTPUT), internal variables (VAR), and retained variables (VAR_RETAIN) maintaining values between calls. Creating motor control FB: inputs include Start_Cmd (BOOL), Stop_Cmd (BOOL), Speed_SP (INT), outputs include Running_Sts (BOOL), Fault_Sts (BOOL), Actual_Speed (INT), internal variables store timers, state machine stages, and diagnostic counters. FB instantiation creates instance: Motor1 (Motor_FB) with unique variable storage, allowing multiple instances Motor1, Motor2, Motor3 controlling different motors using same logic. Array of FB instances: Motors : ARRAY[1..10] OF Motor_FB accessed as Motors[3].Running_Sts checking status of motor 3. Standard function (FUN) differs from FB by lacking internal memory, suitable for calculations or conversions: Temp_Conversion_FUN(Celsius) returns Fahrenheit without retaining historical data. Structured text programming within FBs/FUNs provides clearer logic for complex algorithms compared to ladder: IF-THEN-ELSIF-ELSE structures, FOR loops, CASE statements expressing intent more directly than ladder equivalents. EN/ENO functionality enables conditional execution: EN (enable input) controls whether FB executes, ENO (enable output) indicates successful execution detecting errors within block. Library management exports FBs to library files (.glib) shared across projects and engineering teams, versioned to track modifications and ensure consistency. The intelligent function module (IFM) templates provide pre-built FBs for common applications: PID control, analog scaling, motion positioning reducing development time and providing tested reliable code. Simulation mode tests FB logic without hardware, allowing desktop development and unit testing before commissioning. Protection functionality encrypts FB contents preventing unauthorized viewing or modification, useful for proprietary algorithms or OEM machine builders distributing programs to end users.

Common Challenges and Solutions:

1. Maintaining registration at high speeds

  • Solution: Data Types addresses this through Memory optimization.


2. Handling product variability in automated systems

  • Solution: Data Types addresses this through Type safety.


3. Quick changeover between package formats

  • Solution: Data Types addresses this through Better organization.


4. Synchronizing multiple machines in a line

  • Solution: Data Types addresses this through Improved performance.


Safety Considerations:

  • Guarding around rotating and reciprocating parts

  • Safety-rated position monitoring for setup access

  • Heat hazard protection for seal bars and shrink tunnels

  • Proper pinch point guarding

  • Robot safety zones and light curtains


Performance Metrics:

  • Scan Time: Optimize for 5 inputs and 5 outputs

  • Memory Usage: Efficient data structures for FX5 capabilities

  • Response Time: Meeting Packaging requirements for Packaging Automation

Mitsubishi Diagnostic Tools:

Device memory monitor: Real-time table displaying current values for X, Y, M, D devices with force capability,Entry data monitor: Shows actual rung logic states with contact ON/OFF indication during program execution,Device test: Manually control outputs and set internal relays for wiring verification without program influence,Intelligent module diagnostics: Buffer memory display showing module status, error codes, and configuration,Scan time monitor: Displays current, maximum, and minimum scan times identifying performance issues,Error code history: Chronological log of system errors, module faults, and CPU events with timestamps,CC-Link/network diagnostics: Visual network status showing connected stations, errors, and communication statistics,SD card operation log: Records all SD card read/write operations, file transfers, and access timestamps,Remote diagnosis via Ethernet: Connect GX Works over network for monitoring and troubleshooting without local access,Sampling trace: Records device value changes over time with trigger conditions for intermittent fault analysis,System monitor: Displays CPU load, memory usage, and battery status for predictive maintenance,Safety diagnosis (safety CPU): Dedicated diagnostics for safety I/O discrepancy detection and emergency stop chain status

Mitsubishi's GX Works2/GX Works3 provides tools for performance monitoring and optimization, essential for achieving the 3-6 weeks development timeline while maintaining code quality.

Mitsubishi Data Types Example for Packaging Automation

Complete working example demonstrating Data Types implementation for Packaging Automation using Mitsubishi GX Works2/GX Works3. Follows Mitsubishi naming conventions. Tested on FX5 hardware.

// Mitsubishi GX Works2/GX Works3 - Packaging Automation Control
// Data Types Implementation for Packaging
// Mitsubishi programming supports both traditional device addr

// ============================================
// Variable Declarations
// ============================================
VAR
    bEnable : BOOL := FALSE;
    bEmergencyStop : BOOL := FALSE;
    rVisionsystems : REAL;
    rServomotors : REAL;
END_VAR

// ============================================
// Input Conditioning - Product detection sensors for counting and positioning
// ============================================
// Standard input processing
IF rVisionsystems > 0.0 THEN
    bEnable := TRUE;
END_IF;

// ============================================
// Safety Interlock - Guarding around rotating and reciprocating parts
// ============================================
IF bEmergencyStop THEN
    rServomotors := 0.0;
    bEnable := FALSE;
END_IF;

// ============================================
// Main Packaging Automation Control Logic
// ============================================
IF bEnable AND NOT bEmergencyStop THEN
    // Packaging automation systems use PLCs to coordinate primary,
    rServomotors := rVisionsystems * 1.0;

    // Process monitoring
    // Add specific control logic here
ELSE
    rServomotors := 0.0;
END_IF;

Code Explanation:

  • 1.Data Types structure optimized for Packaging Automation in Packaging applications
  • 2.Input conditioning handles Product detection sensors for counting and positioning signals
  • 3.Safety interlock ensures Guarding around rotating and reciprocating parts always takes priority
  • 4.Main control implements Packaging automation systems use PLCs to
  • 5.Code runs every scan cycle on FX5 (typically 5-20ms)

Best Practices

  • Follow Mitsubishi naming conventions: Mitsubishi programming supports both traditional device addressing (M0, D100, X1
  • Mitsubishi function design: Function block (FB) programming in Mitsubishi creates reusable logic modules wit
  • Data organization: Mitsubishi uses file registers (R devices) and structured data in function block
  • Data Types: Use smallest data type that accommodates the value range
  • Data Types: Use REAL for analog values that need decimal precision
  • Data Types: Create UDTs for frequently repeated data patterns
  • Packaging Automation: Use electronic gearing for mechanical simplicity
  • Packaging Automation: Implement automatic film/label splice detection
  • Packaging Automation: Add statistical monitoring of registration error
  • Debug with GX Works2/GX Works3: Use sampling trace to capture high-speed events occurring faster than
  • Safety: Guarding around rotating and reciprocating parts
  • Use GX Works2/GX Works3 simulation tools to test Packaging Automation logic before deployment

Common Pitfalls to Avoid

  • Data Types: Using INT for values that exceed 32767
  • Data Types: Losing precision when converting REAL to INT
  • Data Types: Array index out of bounds causing memory corruption
  • Mitsubishi common error: Error 2110: Illegal device specified - accessing device outside configured range
  • Packaging Automation: Maintaining registration at high speeds
  • Packaging Automation: Handling product variability in automated systems
  • Neglecting to validate Product detection sensors for counting and positioning leads to control errors
  • Insufficient comments make Data Types programs unmaintainable over time

Related Certifications

🏆Mitsubishi PLC Programming Certification
Mastering Data Types for Packaging Automation applications using Mitsubishi GX Works2/GX Works3 requires understanding both the platform's capabilities and the specific demands of Packaging. This guide has provided comprehensive coverage of implementation strategies, working code examples, best practices, and common pitfalls to help you succeed with intermediate to advanced Packaging Automation projects. Mitsubishi's 15% market share and high - popular in electronics manufacturing, packaging, and assembly demonstrate the platform's capability for demanding applications. Packaging machinery manufacturers across Asia Pacific standardize on Mitsubishi for flexibility, compact form factors, and responsive local technical ... By following the practices outlined in this guide—from proper program structure and Data Types best practices to Mitsubishi-specific optimizations—you can deliver reliable Packaging Automation systems that meet Packaging requirements. **Next Steps for Professional Development:** 1. **Certification**: Pursue Mitsubishi PLC Programming Certification to validate your Mitsubishi expertise 3. **Hands-on Practice**: Build Packaging Automation projects using FX5 hardware 4. **Stay Current**: Follow GX Works2/GX Works3 updates and new Data Types features **Data Types Foundation:** PLC data types define how values are stored, their valid ranges, and operations that can be performed. Proper type selection ensures accuracy and memo... The 3-6 weeks typical timeline for Packaging Automation projects will decrease as you gain experience with these patterns and techniques. Remember: Use electronic gearing for mechanical simplicity For further learning, explore related topics including Data logging, Pharmaceutical blister packing, and Mitsubishi platform-specific features for Packaging Automation optimization.